Streszczenie treści zawartej na stronie nr. 1
Yeoman Exe Midi
Conventional Flue Coal Effect Stove
With upgradeable control valve
Instructions for Use,
Installation and Servicing
For use in GB, IE (Great Britain and Eire)
IMPORTANT
This product contains a Heat resistant glass panel. This panel should be checked during Installation and at each servicing
interval. If any damage is observed on the front face of the glass panel (scratches, scores, cracks or other surface defects), the
glass panel must be replaced and the appliance must not be
Streszczenie treści zawartej na stronie nr. 2
CONTENTS COVERING THE FOLLOWING MODELS: YM-N9171FL / YM-N9171LC YM-P9171FL / YM-P9171LC PAGE APPLIANCE COMMISSIONING CHECkLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 9 Technical Specification 9 Site Requirements 10 Installation 11 Commissioning 14 SERVICING INSTRUCTIONS 15 Servicing Requirements 15 Fault Finding 15 How to replace parts 17 Basic spare parts list 21 2
Streszczenie treści zawartej na stronie nr. 3
APPLIANCE COMMISSIONING CHECkLIST IMPORTANT NOTICE Explain the operation of the appliance to the end user and hand the completed instructions to them for safe keeping as the information will be required when making any guaranteed claims. FLUE CHECk PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECk 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operatin
Streszczenie treści zawartej na stronie nr. 4
USER INSTRUCTIONS 1.7 The manufacturer considers the full outer casing of this 1. GENERAL stove to be a working surface which becomes hot when the stove is lit. A suitable guard is recommended to protect young children, the aged and the infirm. In the event of a gas escape, or if you can smell gas, please take the following steps: 1.8 This stove must only be operated with the door secured firmly in position. If any cracks appear in the glass the —Immediately turn off the gas supply at th
Streszczenie treści zawartej na stronie nr. 5
USER INSTRUCTIONS YELLOW FLAMES APPEAR WHEN THE STOVE HAS 2. LIGHTING THE STOVE REACHED SUFFICIENT HEAT (10 TO 20 MINUTES). IF THE STOVE IS EXTINGUISHED OR GOES OUT DURING USE WAIT 3 MINUTES BEFORE ATTEMPTING 2.1 The control valve is on the right-hand side at the foot of the TO RELIGHT. stove. It has two controls: —The right-hand knob controls the pilot ignition 3. TURNING THE STOVE OFF —The left-hand knob controls the main burner 2.2 Refer to separate instructions if your stove is u
Streszczenie treści zawartej na stronie nr. 6
USER INSTRUCTIONS 4 5. CLEANING THE STOVE Advice on Handling and Disposal of Fire Ceramics 5.1 The fuel effect logs and embers in this stove are made from Refractory Ceramic Fibre (RCF). Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking. Excessive exposure to these materials may cause temporary irritation to eyes, skin an
Streszczenie treści zawartej na stronie nr. 7
USER INSTRUCTIONS HEADING 8 6. FUEL BED ARRANGEMENT 6.1 Place the flame baffle onto the burner and push against the rear tray lip (see Diagram 5). 5 Spacer brackets Heat shield AR0361 6.5 Place five of the loose round coals on the front coal so they lean against the flame baffle, in between the fingers. Place the two rectangular coals against the reflector panels, one either side, behind the front row of loose coals (see Diagram 9). AR0359 9 6.2 Locate the rear panel against the spacer bra
Streszczenie treści zawartej na stronie nr. 8
USER INSTRUCTIONS 11 12. INSTALLATION DETAILS Make sure your installer completes the Appliance Commissioning Checklist on page 3. This records essential details of this stove. In all correspondence, always quote the Model and Serial Number. 13. HOT SURFACES This stove becomes hot during normal use. You must use a AR0364 suitable fire guard to protect children, the elderly and the infirm. 6.8 Replace the glass frame using the 6 x frame fixing screws (see Diagram 4) and close door. 7. GA
Streszczenie treści zawartej na stronie nr. 9
INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Covering the following models: Yeoman Exe Midi YM-N9171FL / YM-N9171LC YM-P9171FL / YM-P9171LC Input kW Model Gas Gas Working NOX Gas Rate (Gross) Aeration Injector Country CAT. Type Pressure Class m³/h High Low Yeoman Exe Midi Natural Gas 4.6 2.5 I 20 mbar 5 1 x 7.5mm 260 0.435 GB, IE 2H YM-N9171FL/LC G20 Gross Gross Yeoman Exe Midi LPG Propane 4.4 2.3 I 37 mbar 5 1 x 13.5mm 110 0.170 GB, IE 3P YM-P9171FL/LC G31 Gross Gross Efficiency Class II
Streszczenie treści zawartej na stronie nr. 10
INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1 1. FLUE AND CHIMNEY REQUIREMENTS B 1.1 The chimney or flue system must comply with the rules in force, and must be a minimum of 127mm (5") in diameter. 1.2 The minimum effective height of the flue or chimney must be 3 metres (10ft). Any horizontal flue run from the rear outlet should not exceed 100mm from the back of the A = 643mm appliance. B = 43mm 1.3 The chimney or flue must be free from any obstruction. Any C C = 12mm damper plates should b
Streszczenie treści zawartej na stronie nr. 11
INSTALLATION INSTRUCTIONS INSTALLATION 2.7 The stove is fitted with the Gazco Flue Sure System, which IMPORTANT: ENSURE THAT THE APPLIANCE IS will act to cut off the gas supply to the appliance in the CORRECTLY ADJUSTED FOR THE GAS TYPE AND event of incorrect operation of the flue. If the system acts CATEGORY APPLICABLE IN THE COUNTRY OF USE. to shut off the gas supply, this indicates that there is REFER TO DATA BADGE AND TECHNICAL insufficient flue pull. If this occurs, a minimum of 10
Streszczenie treści zawartej na stronie nr. 12
INSTALLATION INSTRUCTIONS INSTALLATION 3.5 Check the pull of the flue system by applying a lighted 5 smoke pellet to the flue system opening. If there is a definite flow into the chimney, proceed with the installation, if not warm the chimney for a few minutes. Turn rose to open door IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY REQUIRE ATTENTION - SEEk EXPERT ADVICE. 3.6 The flue system may now be connected to the stove, ensure that all joints are sealed with a suitable fire resistant
Streszczenie treści zawartej na stronie nr. 13
INSTALLATION INSTRUCTIONS INSTALLATION 11 8 AR0362 AR0360 4.11 Place four of the loose round coals behind the first row so that they sit on the fingers, the two outer coals should touch 4.8 Place the log retainer in the two guides as shown in the rectangular coals (see Diagram 12). Diagram 9. 12 9 AR0363 AR2076 4.12 Place the remaining three coals behind the centre row so FOR CLARITY, THE FOLLOWING LOG ARRANGEMENT that they touch the back panel (see Diagram 13). DIAGRAMS DO NOT INCLUDE ILL
Streszczenie treści zawartej na stronie nr. 14
INSTALLATION INSTRUCTIONS COMMISSIONING 1. COMMISSIONING After connecting the gas pipe to the stove: 1.1 PURGE THE SUPPLY PIPE to dispel any debris that might block the controls. 1.2 Connect the gas supply to the 8mm compression elbow at the right-hand rear corner of the stove (see Diagram 1). 1 AR0934 1.3 Connect a suitable pressure gauge to the test point on the inlet fitting. 1.4 Turn on the gas supply. 1.5 Light the stove and check all gas joints for leaks. 1.6 Turn the stove to max
Streszczenie treści zawartej na stronie nr. 15
3.5mm SERVICING INSTRUCTIONS SERVICING REQUIREMENTS/ FAULT FINDING CHARTS 1.3 Special checks: 1. SERVICING REQUIREMENTS —Clean any lint or fluff from the pilot - pay particular attention to the aeration hole in the side of the pilot. —Clean away any fluff or lint from under the burner. IMPORTANT – The glass panel on this appliance should —Check that the spark gap on the pilot is correct. be checked for any signs of damage on the front face of the glass panel (scratches, scores, cr
Streszczenie treści zawartej na stronie nr. 16
SERVICING INSTRUCTIONS FAULT FINDING CHARTS 16 IGNITION FUNCTIONAL CHECk 2 FLAME FAILURE FUNCTIONAL CHECk NO SPARK PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clean the area. Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Consult User Instructions, Section 2, retry. Light the pilot and keep the control knob pushe
Streszczenie treści zawartej na stronie nr. 17
SERVICING INSTRUCTIONS REPLACING PARTS 2.4 Remove the two screws at the back of the firebox and lift 1. GENERAL the burner unit clean (see Diagram 3). 1.1 All main components can be replaced with the stove in 3 place but it is essential to turn off the gas supply at the isolation device before proceeding. For information on the handling and disposal of fire ceramics please refer to User Instructions, Section 5, Cleaning the Fire. ENSURE THE APPLIANCE IS COLD BEFORE STARTING WORk ON IT.
Streszczenie treści zawartej na stronie nr. 18
SERVICING INSTRUCTIONS REPLACING PARTS 3.3 The pilot unit can now be removed by undoing the two 8 screws (see Diagram 6). 6 AR0916 4.3 Replace with a new ignition lead following the same route AR1445 as the old one. Replace the valve cover and the pilot assembly. 3.4 Reassemble in reverse order, do not overtighten. 4.4 Check operation of the new ignition lead. NOTE: SPECIAL CARE SHOULD BE TAkEN WHEN REPLACING THE THERMOCOUPLE TO THE BACk OF THE GAS VALVE TO ENSURE THAT THE SENSOR WIRES
Streszczenie treści zawartej na stronie nr. 19
SERVICING INSTRUCTIONS REPLACING PARTS 6.3 Undo the single screw that secures the left hand side of the 7.2 Undo the magnetic valve-retaining nut from the back of the control cover (see Diagram 10). control valve, gently tap out the magnetic valve and replace with a new unit. Replace the retaining nut and tighten (see Diagram 12). 10 12 AR0915 A AR0915 6.4 To release the right hand side of the control cover insert the narrow blade screwdriver into the slot shown in Diagram 11. Lever it gent
Streszczenie treści zawartej na stronie nr. 20
SERVICING INSTRUCTIONS REPLACING PARTS 9.4 Feed the cable back through the hole as you replace the 9. GAzCO FLUE SURE SYSTEM bracket. When the bracket is located correctly it will sit flush with the back panel without force being required. If not positioned correctly the bracket will sit at an angle (see 9.1 Open the door and remove the ceramics, placing them Diagram 17). carefully to one side. Undo the two screws in the back of the firebox and carefully withdraw the bracket (see Diagram