Streszczenie treści zawartej na stronie nr. 1
INSTALLATION AND OPERATION MANUAL
Direct-Vent
Gas Stove
Retain These Instructions For Future Reference
P/N 775,227M Rev. A, 05/2007
A French manual is available upon request. Order P/N 775,227CF.
Ce manuel d’installation est disponible en francais, simplement
en faire la demande. Numéro de la pièce 775,227CF.
In the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or gas fitter
• See Table of Contents for location of additional Commonwealth of
Report
Streszczenie treści zawartej na stronie nr. 2
Table of Contents Cautions & s afety ..........................................................................................3 o rifiCe s ize / a titudel a djustment .........................................................................4 Codes & a alspprov ....................................................................................... 4-5 Cthommonweal o f m assaChusetts r equirements ......................................................5 p re -i tionallanst .......................
Streszczenie treści zawartej na stronie nr. 3
Cautions & s afety FOR YOUR SAFETY do not install or operate your Vin- Your Lennox™ gas stove must be equipped for the tage™ gas stove without first reading & understanding proper fuel type & altitude at which it will be operated. this manual. Any installation or operation of the appli- Any operation outside the parameters outlined in this ance deviating from that which is stated in this manual manual may result in a hazardous condition & will void WILL void the warranty & may be haz
Streszczenie treści zawartej na stronie nr. 4
t he v ageint ™ s tove Orifice Size/Altitude Adjustment For altitudes above 2,000 feet (In Canada 4,500 FT/1370 • Must conform with all local, state, and national installa- M),the orifice should be de-rated by 4% for every 1,000 feet tion codes. In the absence of local codes, the installation to maintain the proper ratio of gas to air. Improper orifice must conform with National Fuel Gas Code ANSI Z223.1 sizing may result in damage
Streszczenie treści zawartej na stronie nr. 5
Inspection Commonwealth Of Massachusetts Requirements The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed Note: The following requirements reference various Massachusetts inaccordance with theprovisions of 248CMR 5.08(2)(a)1 through 4. and national codes not contained in this document. For
Streszczenie treści zawartej na stronie nr. 6
Millivolt Valve Pre-Installation This stove is operated with a millivolt valve and therefore burnseven during a power outage. f turesea Installation Options Fuel Residential This stove comes from the factory equipped to burn natural Ventedvertical and horizontal gas at a specified elevation. The stove can be converted to Manufactured(mobile) home burn LP gas (liquid propane) by changing the cassette (valve Naturalgas (NG) or p
Streszczenie treści zawartej na stronie nr. 7
d imensions p aringrep y our v ageint ™ s tove f or i tionallanst The gas line screws into the gas valve at the back of the Read all instructions before beginning your installation. If stove5” in from the rightside of thestove and 4-3/16” up instructions have not been read carefully, your installation fromthe base of the unit. could void your warranty and may create a serious fire, health, or other safety hazard. t op v iew The Lennox
Streszczenie treści zawartej na stronie nr. 8
Combustible Wall ClearanCes to Combustibles a lCove dimensions Minimum clearances to combustible materials shown here The minimum width between alcove side walls is 30-1/2” are in inches (millim e t e r s ) . S e e p a g e 7 f o r p i p e c le a r a n c e s . (775mm). The glass door lifts up to access the firebox on the stove. Therefore, if the
Streszczenie treści zawartej na stronie nr. 9
Installation b affle & l og s et i tionallanst Baffle The cast iron baffle is wrapped in foam and shipped between the outside of the firebox and the outer shell of the stove. Remove the foam and install the baffle in the rectangular hole in the top of the firebox. The baffle rests unsecured in thehole. Figure 10 Log Set & Embers Caution: If the logs are not properly installed, your stove will not function properly. Parts list: rear log, left fron
Streszczenie treści zawartej na stronie nr. 10
s ide -i tnser i tionallanst Follow these steps to install the side stone or cast iron inserts in the Vintage™gas stove: UpperCast Piece Retainer 1. Remove the cast iron top and setit aside. 2. Remove the cast iron upper piece A - see Figure 14. Complete this step by unscrewing the (2) 5/32 hex-head Heatshield Stoneor Cast Insert screws labeled B in Figure 17. Lift out the upper cast pieceA withthe retaining bracketD attached. C
Streszczenie treści zawartej na stronie nr. 11
Minimum Components for Horizontal Installation: v ent i tionallanst Horizontal Termination Kit which includes: v enting : • 16-5/8”x 6” BlackPipe The Vintage™ gas stove has been tested and listed as • 1 Riser VentT erminal a direct vent heater system by OMNI-Test Laboratories, • 1 WallPenetration Heat Shield(W all Thimble) (2 pcs) Beaverton, Oregon and is recommended for use with • 1 Decorative Wall Trim (black) Security™ Secure Vent pipe*. • 1T ubeMill-Pac Imp
Streszczenie treści zawartej na stronie nr. 12
v ent p tsar l ist h alorizont v ent i tionallanst Direct vent pipe Security™ Secure Vent™ * may be used Venting terminals may not be recessed into a wall or with the Vintage™ gas stove. Please see the lists below siding. to verify the components available from each direct vent pipe manufacturer. Snorkel terminations are available for 1. Set the unit in the desired location. Check whether or applications which may require vertical rise on the
Streszczenie treści zawartej na stronie nr. 13
s norkel t tionsermina For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall snorkel terminations are available. When using a snorkel, the stove can be vented Framed Hole: directly out the back. There is a vent starter collar fastened 9-1/4”x 10-1/4” to the stove (to vent straight out the back), remove the four High screws securing the collar, rotate the collar 180 degrees and refasten
Streszczenie treści zawartej na stronie nr. 14
f lue r estriCtors This stove uses balanced flue technology to ensure proper combustion. As such, flue restrictors may need to be in- stalled depending on the vent configuration of your stove. The drawings on page 15 show all the allowable pipe con- FlueOpening in the figurations for the Vintage™ gas stove. To properly install topof the firebox the flue restrictor, first find your pipe configuration in the drawings on page 15 an
Streszczenie treści zawartej na stronie nr. 15
h alorizont t tionsermina To install the stove with pipe directly out the back, a snorkel The shaded areas in the diagram below show all allow- is not required for the Vintage™ gas stove. A snorkel is re- able combinations of vent configurations with horizontal quired for the Vintage. See page 13 for snorkel installation terminations. Horizontal sections of pipe require 1/4” of instructions. rise for every 12” of run. A second 90
Streszczenie treści zawartej na stronie nr. 16
V e xterior h alorizont v ent t tionermina ClearanCe r equirements * See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal G Termination 18” V Ventilated Soffit A Inside Corner = 9" in U.S. A = 1" in C anada DETAIL D H ft. B B D E X C A A V Fixed Operable V L V Closed Window ft. Window V F C J B V M C B B C V I A X = Air Supply Inlet V = Vent Terminal = Area where Terminal is NOT permitted Minimum Clearances Canadian Installation * U
Streszczenie treści zawartej na stronie nr. 17
If the pressure is not sufficient, make sure the gas supply line Gas Line Installation is large enough, The supply regulator is properly adjusted, and the total gas load for the residence does not exceed the This stove must be connected to the gas line in accordance amount supplied. with local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada, the current CAN/CSA B149.1 installa- The appliance and its individual shut off valve must
Streszczenie treści zawartej na stronie nr. 18
C. Use only your hand to push in or turn the gas control Operating Instructions knob. Never use any tool. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service p re -l ighting CheCklist technician. Force or attempted repair may result in a fire Be sure to check these items before the initial lighting of or explosion. thestove: D. DO NOT use this appliance if any part has been under water. c T
Streszczenie treści zawartej na stronie nr. 19
ON LO TO TURN OFF GAS TO APPLIANCE Flame Color & Behavior 1. Turn off the "ON/OFF" rocker switch and/or thermostat (if Your Vintage™ gas stove is designed for maximum heating installed)to its lowest setting. efficiency. Therefore, upon lighting of the main burner the 2. Turn off electric power to the appliance if service is to flames will be semi-transparent or “bluish.” After 10-20 be performed. minutes of operation the logs will heat
Streszczenie treści zawartej na stronie nr. 20
a ir s hutter a djustment q uiet o tionpera The air shutter control lever is located on the bottom of the As the Vintage™ gas stove is burning, a number of normal stove directly to the left of the gas valve. The lever is linked operational sounds may be heard. The flow of gas through to the primary air shutter on the main burner. The air shutter the gas valve and orifice may make a rushing or whistling regulates the amount o