Streszczenie treści zawartej na stronie nr. 1
installation & operating Manual
The harman Clarity 929bv gas Stove
“Ce manuel est disponible en Français sur demande”
R5
SAFETY NOTICE
PlEASE rEAd ThIS ENTIrE mANA u l EFO b rE YOu INSTAll ANd SE u YOur NEw rOOm hEATEr. F AIlurE
TO FOllOw INSTruCTIONS mAY rESul T IN PrOPErTY dAmAE g , bOdIl Y INjur Y, Or EvEN dEATh.
IF ThIS hArmAN STOvE IS NOT PrOPErl Y INSTAllEd, A hOuSE FIrE mAY rESul T. FOr YOur SAFETY, FOl -
lO INST w AllATION dIrECTIONS.
CONTACT lOCAl Ibu ldINg Or FIrE OFFICIAlS AO b T
Streszczenie treści zawartej na stronie nr. 2
Table of ConTenTs INTRODUCTION............................................................3 INSTALLATION..............................................................4 . Clearances..................................................................4 . Venting........................................................................5 . Test.for.Flue.Spillage.................................................5 . Assembly....................................................................6 . Connecting.t
Streszczenie treści zawartej na stronie nr. 3
Introduction. Several.issues.must.be.addressed.when.selecting.a. The.Harman.Clarity.929BV.Vented.Gas.Heater.is.a. suitable.location.for.your.Clarity.Gas.Heater..Observ- listed gas-fired vented room heater tested by Intertek ing.required.clearances.to.combustible.materials,.the. Testing/Warnock. Hersey. to.ANSI. standard. Z21.88- proximity. to. a. safe. chimney. or. venting. system,and. 2002,.CSA.2.33-M02,.and.CAN/CGA-2.17-M91.. the.accessibility.of.the.gas.and.electrical.supply.must. The. insta
Streszczenie treści zawartej na stronie nr. 4
Due to high temperatures, the Clarity Vented Gas Heater should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the haz- ards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the Clarity Vented Gas Heater. Clearance from corner of unit to walls Clothing or other flammable materials should not be placed on or near the
Streszczenie treści zawartej na stronie nr. 5
VenTInG WARNING: Operation of this heater when not con- nected to a properly installed and maintained venting Use Only Approved Venting system or tampering with the vent safey shutoff system The.Clarity.gas.heater.is.tested.and.listed.for.connection. can result in carbon monoxide (Co) poisoning and pos - to.a.4".(100.mm).listed.Class.B.venting.system.. sible death. If.the.unit.is.installed.to.vent.through.an.approved.masonry. The.Clarity.gas.heater.is.equipped.with.its.own.internal. chimney.or
Streszczenie treści zawartej na stronie nr. 6
asseMbl Y The.Clarity.is.shipped.from.the.factory.with.the.log.set. packed inside the firebox. To prepare the stove for installa- 1 tion,.the.log.set.must.be.unpacked,.the.appropriate.burner. system.module.for.either.natural.gas.or.propane.installed,. and.the.logs.installed. 2 Removing the Glass Front NOTE:.The.glass.front.is.heavy..Be.prepared.for.its. weight.when.lifting.it.to.avoid.damage.during.removal. The.wing.doors.on.each.side.are.held.closed.by.magnets.. 4 Push.on.each.door.to.open.it.
Streszczenie treści zawartej na stronie nr. 7
Install the Back Log and Back Brick Panel These. two. components. are. installed. as. a. single. piece.. Rest.the.back.brick.panel.on.the.shelf.located.on.the.back. side.of.the.back.log,.and.center.it..Holding.the.two.pieces. as.a.single.unit,.tilt.the.top.forward.slightly.and.manuever. it.over.the.top.of.the.rear.burner—taking.care.that.the.top. corners.clear.the.front.opening..Place.it.snugly.against.the. back.wall.and.center.it. Install the Side Brick Panels These.slide.into.place.along.each.
Streszczenie treści zawartej na stronie nr. 8
ConneCTInG THe Hea TeR natural Gas: To a Gas sUPPl Y Maximum. inlet. pressure. 7.0". w.c.. (1.74. kPa)... Minimum. inlet. pressure. 5.0". w.c.. (1.25. kPa).. Burn Only the Fuel for which the Heater is Equipped Gas.manifold.pressure.3.5".w.c..(0.87.kPa) The.Clarity.B-Vent.will.burn.either.natural.gas.or.pro- pane,.but.requires.a.dedicated.burner.system.module.for. lPG Gas: either.fuel..The.label.on.the.burner.system.module.indicates. Maximum. inlet. pressure. 13". w.c.. (3.24. kPa)... the.fue
Streszczenie treści zawartej na stronie nr. 9
ConneCTInG THe CoRDseT The.Clarity.B-Vent.Gas.Heater.must.be.installed.in.ac- cordance.with.local.codes.or,.in.the.absence.of.local.codes,. with.the.most.recent.edition.of.the.National.Electrical.Code. ANSI/NFPA.70,.or.the.current.Canadian.Electrical.Code. Terminal.strip.for. C22.1. thermostat.connec- NOTE:.The.convection.fan.requires.a.120.VAC.supply. tion for.operation,.but.the.heater.can.be.operated.without.the.fan. as.in.the.case.of.a.power.outage. Plug. the. 3-prong. grounded. electrical. c
Streszczenie treści zawartej na stronie nr. 10
aIR sHUTTeR aDJUsTMenT MonIT oRInG THe Gas flaMe The final step of the installation is to check the flame Periodically, the flames of the Clarity B-Vent Gas Heater pattern,.which.should.resemble.the.pattern.illustrated.in.the. should be checked while it is operation. The flames should right column: The flames should be relatively well-defined be relatively well-defined and stable. They should be bright and.stable..They.should.be.bright.yellow.with.a.blue.base. yellow.with.a.blue.base.where.at
Streszczenie treści zawartej na stronie nr. 11
Operation HoW T o lIGHT THe fIRe 1...STOP!..Read.the.safety.information.on.the.left.side. ..•If.the.knob.does.not.pop.up.when.released,.stop.and. of.the.panel.below. immediately.call.your.service.technician.or.gas.supplier. 2...If.using.the.optional.thermostat,.set.thermostat.to.the. ..•If.the.pilot.will.not.stay.lit.after.several.tries,.turn.the. lowest.setting. gas.control.knob.to."OFF".and.call.your.service.technician. 3...Turn.off.electric.power.to.the.appliance. or.gas.supplier. 4...Turn.th
Streszczenie treści zawartej na stronie nr. 12
CleanInG THe loG seT anD fIRebox Maintenance During.the.annual.inspection.and.maintenance.appoint- A qualified service person recommended by your ment,.the.service.person.should.clean.dust,.lint,.and.any. Harman.dealer.should.conduct.an.annual.inspection.and. light accumulation from the logs and the firebox area. maintenance.of.your.Clarity,.its.venting,.and.the.installa- An.extra-soft.brush.should.be.used.on.the.logs.as.they. tion to keep it running safely and efficiently. These pro- are extr
Streszczenie treści zawartej na stronie nr. 13
The Clarity B-Vent gas heater, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the current edition of the National Electri- cal Code, ansI/nfP a 70 in the United states or the current Canadian electrical Code Csa 22.1 in Canada. 1
Streszczenie treści zawartej na stronie nr. 14
Parts.List The.following.replacement.parts.for.your.Harman.Clarity.B-Vent.are.available.from.your.Harman.dealer. ID# Part no. Part 39. 3-40-08230. Pilot,.LP 1. 1-89-08270. BVG.weldment 40. 3-40-08228. Thermocouple 2. 1-10-08262-1. Left.wing.door 41. 3-40-08220. Piezo.ignitor 3. 1-10-08262-2. Right.wing.door 42. 3-31-08282. 90°.brass.elbow 4 3-40-08286 1/2" gas inlet flex 43 3-31-08283 1/4" tp 3/8" male compression fitting 5. 3-40-08235. Rear.log 44 3-31-08284 3/8" tp 3/8" male compression fittin
Streszczenie treści zawartej na stronie nr. 15
Clarity.B-Vent.-.Exploded.View 1
Streszczenie treści zawartej na stronie nr. 16
Clarity.Burner.Module.-.Exploded.View 38 49 40 37 14 13 12 52 33 32 41 31 51 50 43 44 42 48 1
Streszczenie treści zawartej na stronie nr. 17
Appendix.A step 3: Using a small flat-blade screwdriver, remove ConVeRTInG THe ClaRITY b-VenT fRoM the.three.screws.that.hold.the.LP.knob.module.in.place.. one Gas To anoTHeR In THe fIelD Remove.the.module.and.replace.it.with.the.Natural.Gas. module.from.the.kit..See.kit.instructions. step 4: Affix the conversion label to the valve so that any no Te : THe Con Ve Rs Ion s Hall be Ca R- future.service.tech.etc....can.plainly.see.that.the.valve.was. RIe D o UT In a CCo RDan Ce WITH THe Re - co
Streszczenie treści zawartej na stronie nr. 18
Appendix.B De-Ra TInG foR HIGH al TITUDe For.U.S..installations,.the.Clarity.B-Vent.is.approved. .For.high.altitude.installations.consult.the.local.gas.dis- for.elevations.up.to.2000.feet.using.the.factory-installed. tributor.or.the.authority.having.jurisdiction.for.proper.rating. burner.injectors..At.elevations.above.2000.feet,.U.S..codes. methods. require.a.decrease.in.the.input.rating.by.changing.the.burner. NOTE:.The. difference. in. altitude. derating. requirements. injectors.to.a.smaller.s
Streszczenie treści zawartej na stronie nr. 19
Clarity.B.Vent.. Gas Heater Specifications Tested.to.ANSI.Z21.88-2002,.CSA.2.33-M02,.CAN/CGA.2.17-M91. . na TURal Gas PRoP ane Input.Rating.(Btu/hr).(0-1375.m). 40,000. 40,000 Min..Input.Rating.(Btu/hr)..(0-1375.m). 27,000. 28,000 Injector.Sizes.(DMS).(front/center/rear..(0-1375.m). 47/56/39. 56/71/53 Manifold.Pressure.(in.w.c./kPa).... 3.5/0.87. 10.0/2.49 Minimum.Manifold.Pressure.(in.w.c./kPa).... 1.7/0.42. 5.9/1.47 Minimum.Inlet.Pressure.(in.w.c./kPa).... 5.0/1.25. 11.0/2.74 Maximum.Output.(B
Streszczenie treści zawartej na stronie nr. 20
HaRMan GolD W aRRanTY 6 YeaR TRansfeRable lIMITeD WaRRanTY (Residential) 1 YeaR lIMITeD W aRRanTY (Commercial) Harman.Stove.Company.warrants.its.products.to.be.free.from.defects.in.material.or.workmanship,.in.normal.use.and.ser- vice,.for.a.period.of.6.years.from.the.date.of.sales.invoice.and.for.mechanical.and.electrical.failures,.in.normal.use.and.service,. for.a.period.of.3.years.from.the.date.of.sales.invoice. If.defective.in.material.or.workmanship,.during.the.warranty.period,.Harman.Stove