Installation & Operating Manual
The Harman Clarity 929 DV
Direct Vent Gas Stove
A RMA
H N
“Ce manuel est disponible en Français sur demande” R5
SAFETY NOTICE
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES
IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOL
Streszczenie treści zawartej na stronie nr. 2
CONTENTS INTRODUCTION ..........................................3 INSTALLATION ............................................4 Clearances...........................................4 Venting .................................................5 Requirements for Terminating the Venting .............................................................6 Assembly .............................................7 Connecting to a Gas Supply...............9 Connecting the Cordset.................. 10 Connecting the
Streszczenie treści zawartej na stronie nr. 3
INTRODUCTION When operating your Harman Clarity Gas Heater, re- The Harman Clarity Direct Vent 929DV Gas Heater is a spect basic safety standards. Read these instructions care- listed gas-fired direct vent room heater tested by Inchcape fully before you attempt to operate the heater. Failure to Testing/Warnock Hersey to ANSI standard Z21.88-2002, do so may result in damage to property or personal injury CSA 2.33-M02, and CAN/CGA-2.17-M91. and may void the product warranty. The installation of th
Streszczenie treści zawartej na stronie nr. 4
4" (100 mm) INSTALLATION IMPORTANT NOTICE Due to high temperatures, the Clarity Direct Vent Gas Heater should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the haz- ards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable materials should not be placed on or near the Clarity Dir
Streszczenie treści zawartej na stronie nr. 5
VENTING WARNING: The flow of ventilation air must not be Use Only Approved Venting obstructed. The Clarity Direct Vent Gas Heater has been tested Horizontal and Vertical Venting Requirements and is listed for installation with Simpson Duravent GS vent- ing components. The Simpson Duravent GS warranty will The maximum horizontal run allowed for the Clarity Di- be voided, and serious fire, health, or other safety hazards rect Vent is 10 feet. The maximum vertical rise and maxi- may result from any
Streszczenie treści zawartej na stronie nr. 6
VENTING 1 Requirements for Terminating the Venting As specified in CAN 1 B1-149 Installation Codes (currend edition). Note: local codes or regulations may require dif- WARNING: Venting terminals must not be recessed ferent clearances. into a wall or siding. 2 A vent shall not terminate directly above a side-walk or In addition, the following must be observed: paved driveway which is located between two single fam- A. The clearance above grade, or a veranda, porch, deck 1 ily dwellings and ser
Streszczenie treści zawartej na stronie nr. 7
ASSEMBLY Remove and Unwrap the Log Set The Clarity is shipped from the factory with the log set packed inside the firebox. To prepare the stove for installa- As shown in the photo in the right column, the log set tion, the log set must be unpacked, the appropriate burner consists of a back log (1), a center log that has a pilot-view- system module for either natural gas or propane installed, ing port in the left end (2), two ember strips (3), and a branch and the logs installed. that rests on to
Streszczenie treści zawartej na stronie nr. 8
ASSEMBLY Install the Branch With the module installed and secured, reach through the side access ports and plug in the electrical connections. Orient the branch with the forked end toward the left (Two AMP Mate-N-Lok connectors). rear of the stove and slip it over the two locator pins, one on top of the back log and the other on the top of the center log. Secure the Glass Front NOTE: The glass front is heavy. Lift it carefully to pre- vent damage. Center the glass on the opening and suspend it i
Streszczenie treści zawartej na stronie nr. 9
CONNECTING THE HEATER TO A GAS SUPPLY Burn Only the Fuel for which the Heater is Equipped Natural Gas: Maximum inlet pressure 7.0" w.c. (1.74 kPa) The Clarity Direct Vent will burn either natural gas or Minimum inlet pressure 5.0" w.c. (1.25 kPa) propane, but requires a dedicated burner system module for Gas manifold pressure 3.5" w.c. (0.87 kPa) either fuel. The label on the burner system module indicates the fuel for which it is equipped. A second label, located LPG Gas: near the rating plate,
Streszczenie treści zawartej na stronie nr. 10
CONNECTING THE HEATER TO CORDSET Connecting the Cordset Connecting the Optional Thermostat The Clarity Direct Vent Gas Heater must be installed in If the optional accordance with local codes or, in the absence of local codes, thermostat is used, it with the most recent edition of the National Electrical Code must be plugged into ANSI/NFPA 70, or the current Canadian Electrical Code the terminal strip lo- C22.1. cated in the left rear corner of the heater. Terminal WARNING: This heater is equippe
Streszczenie treści zawartej na stronie nr. 11
AIR SHUTTER ADJUSTMENT AIR SHUTTER ADJUSTMENT The final step of the installation is to check the flame pat- Monitoring the Gas Flame tern, which should resemble the pattern illustrated in the Periodically, the flames of the Clarity Direct Vent Gas right column: The flames should be relatively well-defined Heater should be checked while it is operation. The flames and stable. They should be bright yellow with a blue base should be relatively well-defined and stable. They should be where attached
Streszczenie treści zawartej na stronie nr. 12
OPERATION HOW TO LIGHT THE FIRE 15. Set the High-Low Regulator to desired setting: turn 1. STOP! Read the safety information on the left side of fully counterclockwise for High and fully clockwise for Low. the panel on page 13. NOTE: An odor resulting from the initial heating of new 2. If using the optional thermostat, set thermostat to the materials in your heater is not unusual during the first fire, lowest setting. and in most cases will disappear after an hour or two. 3. Turn off electri
Streszczenie treści zawartej na stronie nr. 13
SAFETY/LIGHTING LABEL 13 Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.
Streszczenie treści zawartej na stronie nr. 14
MAINTENANCE A qualified service person recommended by your Har- Cleaning the Log Set and Firebox man dealer should conduct an annual inspection and main- During the annual inspection and maintenance appoint- tenance of your Clarity, its venting, and the installation to ment, the service person should clean dust, lint, and any light keep it running safely and efficiently. The following proce- accumulation from the logs and the firebox area. An extra- dures should be performed only by a qualified
Streszczenie treści zawartej na stronie nr. 15
WIRING DIAGRAM Clarity Direct Vent Wiring Diagram The Clarity Direct Vent gas heater, when installed, must be electrically grounded in accordance with current local codes or, in the absence of local codes, with the current edition of National Electrical Code, ANSI/NFPA 70 in the United States or the current Canadian Electrical Code CSA 22.1 in Canada. 15 Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.
Streszczenie treści zawartej na stronie nr. 16
PARTS LIST The following replacement parts for your Harman Clarity Direct Vent are available from your Harman dealer. ID# Part No. Part 1. 1-89-08250 3-40-08715 DVG weldment 39. Pilot, LP 2. 3-44-08294 Starting Collar Gasket 40. 3-40-08906 Thermocouple 3. 3-40-3849239 Starting Collar 41. 3-40-08220 Piezo ignitor o 4. 3-40-08286 1/2” gas inlet flex 42. 3-31-08282 90 brass elbow 5. 3-40-08235 Rear log 43. 3-31-08283 1/4” tp 3/8” male compression fitting 6. 3-40-08236 Front log 44. 3-31-08234 3/8
Streszczenie treści zawartej na stronie nr. 17
PARTS Clarity Parts 3 61 62 55 17 54a 21 57 16 54b 18 17 16 66 58a 59a 56 16 27 17 59b 58b 65 1 60 64 63 24 52/53 67 17 Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.
Streszczenie treści zawartej na stronie nr. 18
CLARITY BURNER MODULE : EXPLODED VIEW 38 49 40 37 14 13 12 52 33 32 41 31 51 50 43 44 42 48 18 Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.
Streszczenie treści zawartej na stronie nr. 19
SPECIFICATIONS Clarity Direct Vent 929DV Gas Heater Tested to ANSI Z21.88-2002, CSA 2.33-M02, and CAN/CGA 2.17-M91. NATURAL GAS PROPANE Input Rating (Btu/hr) (0-4500 ft) (0-1375 m) 40,000 40,000 Min. Input Rating (Btu/hr) (0-4500 ft) (0-1375 m) 27,000 28,000 Injectors (DMS) (front/middle/rear) (0-4500 ft) (0-1375 m) 45/56/39 56/71/53 Manifold Pressure (in w.c./kPa) 3.5/0.87 10.0/2.49 Minimum Manifold Pressure (in w.c./kPa) 1.7/0.42 5.9/1.47 Minimum Inlet Pressure (in w.c./kPa) 5.0/1.25 11.
Streszczenie treści zawartej na stronie nr. 20
APPENDIX A Converting the Clarity Direct Vent 4. Unplug the Electrical Connectors from One Gas to Another in the Field Reach through the side access port and unplug the NOTE: THE CONVERSION SHALL BE CAR- two multi-pin connectors and the white lead from the fan. RIED OUT IN ACCORDANCE WITH THE RE- 5. Remove from the theaded studs the two wing nuts QUIREMENTS OF THE PROVINCIAL OR LOCAL that secure the module from underneath, one on each AUTHORITIES HAVING JURISDICTION AND IN side. ACCORDANCE WITH