Streszczenie treści zawartej na stronie nr. 1
OWNER’S MANUAL
EASTWOOD 1900 WOOD STOVE
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED WOOD
STOVE
Verified and tested following
ULC S627 and UL 1482 Standards
by:
Manufactured by : STOVE BUILDER INTERNATIONAL INC.
250, de Copenhague, Saint-Augustin-de-Desmaures (Québec) G3A 2H3
Tel : (418 ) 878-3040
Fax : (418 ) 878-3001
www.drolet.ca
READ AND KEEP THIS MANUAL FOR REFERENCE
45284
Streszczenie treści zawartej na stronie nr. 2
INTRODUCTION Stove Builder International, one of the most important wood stove and fireplace manufacturers in North America, congratulates you on your purchase and wishes to help you get maximum satisfaction from your wood stove. In the pages that follow, we will give you advice on wood heating and controlled combustion as well as technical specifications regarding installation, operation and maintenance of the model you have chosen. The instructions pertaining to the installation of
Streszczenie treści zawartej na stronie nr. 3
TABLE OF CONTENTS 1.1 GENERAL INSTALLATION ................................................................................. 4 1.2 POSITIONING THE STOVE ................................................................................. 5 1.3 CLEARANCES ..................................................................................................... 5 1.3.1 Reduced clearances using shielding .......................................................... 7 1.4 FLOOR PROTECTOR ...............
Streszczenie treści zawartej na stronie nr. 4
4.5 CHIMNEY (FLUE) CLEANING ........................................................................... 40 4.6 BAFFLE INSTALLATION FOR ESCAPE 1800 MODEL ................................... 40 4.5 SECONDARY AIR TUBE REPLACEMENT ....................................................... 42 SECTION 5.0 SPECIFICATIONS ................................................................................ 43 DROLET LIMITED LIFETIME WARRANTY ............................ Erreur ! Signet non défini. 3
Streszczenie treści zawartej na stronie nr. 5
SECTION 1.0 - INSTALLATION When installed and operated as described in these instructions, the Eastwood 1900 EPA wood stove is suitable for use as a freestanding wood stove in residential installations. The Eastwood 1900 EPA wood stove is not intended for installation in a bedroom or a mobile home. In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local code
Streszczenie treści zawartej na stronie nr. 6
1.2 POSITIONING THE STOVE It is very important to position the wood stove in an area that will favour the most efficient heat distribution throughout the house. The stove should therefore be installed in the room where the most time is spent, and in the most spacious room possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a wood stove. A wood stove also functions by convection, that is through the displacement of hot air accelerated upward
Streszczenie treści zawartej na stronie nr. 7
Figure 1.3 Clearances to combustible materials 6
Streszczenie treści zawartej na stronie nr. 8
1.3.1 Reduced clearances You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. These heat radiation shields must be installed permanently, and can include sheet metal, a rigid non-combustible sheet or a masonry wall. Clearances of not less than 1" (25 mm) and not more than 3" (76 mm) between the bottom of the shield and the floor and not less than 3" (76 mm) between the top of the shield and the ceiling must be respected
Streszczenie treści zawartej na stronie nr. 9
Graphic 1 A- Clearance to combustible material with no protection. B- 500 mm (20 po.) minimum; C- 25 mm (1 po.) minimum; D- Between 25 mm (1 po.) and 75 mm (3 po.) ; E- 75 mm (3 po.) minimum; F- 450 mm (18 po.) minimum. 1- Wall shielding ; 2- Non-combustible spacers ; 3- Ceiling shielding ; 4- Combustible wall ; 5- Ceiling; 6- Heater (side view) ; 7- Heater (top view). 8
Streszczenie treści zawartej na stronie nr. 10
Graphic 2 A- 25 mm (1 po.) minimum; 1- Combustible wall ; 2- Non-combustible spacer; 3- 0.61 mm (0.024") sheet metal. Graphic 3 A- 25 mm (1 po.) minimum; 1- Combustible wall; 2- Non-combustible spacer; 3- Fire-proof support; 4- Ceramic tile or equivalent non-combustible material. _____________________________________________________________________________ Graphic 4 A- 25 mm (1 po.) minimum; 1- Combustible wall; 2- Non-combustible spacer; 3- 0.61 mm (0.024
Streszczenie treści zawartej na stronie nr. 11
Graphic 5 A- 25 mm (1 po.) minimum; 1- Combustible wall; 2- Non-combustible spacer; 3- Brick. Graphic 6 A- 25 mm (1 po.) minimum; 1- Combustible wall; 2- Non-combustible spacer; 3- 0.61 mm (0.024") sheet metal; 4- Brick 10
Streszczenie treści zawartej na stronie nr. 12
1.4 FLOOR PROTECTOR If the stove is to be installed on top of a combustible floor, it must be guarded by a non-combustible material extending at least 18” (300mm) from the front and 8” (200mm) from the sides and the back of the firebox., as shown in Figure 1.4 below. Please note that a floor protection is required with the pedestal models for spark and ash shielding, but not for limiting floor temperatures from the radiant heat of the stove. The stove was designed and safety tested so
Streszczenie treści zawartej na stronie nr. 13
TIPS ON WOOD HEATING Wood is a renewable energy. It is also a very clean heat source when used with appliances that are certified by the U.S. Environmental Protection Agency (EPA), a standard accepted in Canada as well. EPA-certified wood stoves are different than conventional wood stoves. Burning with an EPA-certified wood stove may therefore require that you modify some of your heating habits. To get the most satisfaction out of your new wood-heating system, please make sure you go t
Streszczenie treści zawartej na stronie nr. 14
SECTION 2.0 CHIMNEY (FLUE SYSTEM) 2.1 DEFINITIONS For clarity, the following definitions should be used with respect to these instructions: • A chimney system consists of a connector off the top of the stove, and a chimney, which attaches to the connector and terminates outside the house. • A chimney can be a masonry chimney (of masonry construction with an inside liner), or a factory built chimney. • A factory built chimney can be a double walled chimney (two concentric pipes with
Streszczenie treści zawartej na stronie nr. 15
If you are using a masonry chimney, it is important that it be built in compliance with the specifications of the Building Code. It must be lined with fire clay bricks, or clay tiles, sealed together with fire cement, or have a listed solid fuel burning stainless steel liner. Round chimneys are the most efficient. The interior diameter of the chimney should be identical to the stove's smoke exhaust. A chimney which is too small may cause draft problems, since it may not have the requ
Streszczenie treści zawartej na stronie nr. 16
FIGURE 2.2 Minimum Height of the Chimney 2.2.1 Step by step installation of your factory-built chimney The way to install your chimney may vary from one chimney manufacturer to another. The instructions contained in this manual are based on the recommendations of chimney manufacturers whose products are sold at many North American retailers of wood stoves and related heating accessories. Wall support system If your chimney must rise along an outside wall, you need to connect i
Streszczenie treści zawartej na stronie nr. 17
Typical installation through the wall FIGURE 2.2.1 (A) Typical installation through the wall 16
Streszczenie treści zawartej na stronie nr. 18
1- Start by positioning your stove where you would like it to go, taking into account the minimum clearances to combustible material. You will then be able to determine where the chimney will pass through the wall. You will probably have to adjust the stove position slightly to ensure that your chimney will run between the studs. You can use a stud finder to locate the studs. Use a spoke saw or jig saw to cut a hole, remembering that you need to maintain a clearance of 2 inches betwe
Streszczenie treści zawartej na stronie nr. 19
4- Then, from outside the building, slide a short chimney length (attached to the tee) through the wall thimble. The chimney must extend at least 3 inches into the living space where it attaches to the stove pipe. 5- You can now install the wall support. Simply slide the wall support up to the tee, ensuring that the adapter on the support engages with the female coupler on the bottom of the tee. When the wall support is level and properly positioned, you can use lag bolts to secu
Streszczenie treści zawartej na stronie nr. 20
7- Authorities require that the chimney extend not less than 3 feet above the highest point where it passes through the roof of a building and not less than 2 feet above any portion of the building within 10 feet. If the chimney extends more than 5 feet above the roof deck, roof guys with telescoping legs and draw bands are required. 8- Finally, twist on your rain cap and you can head back inside. 9- You are now ready to connect your chimney to your stove. Simp