Streszczenie treści zawartej na stronie nr. 1
MODEL 34
MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO
CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND.
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
− Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
TABLE OF CONTENTS MODEL 34 SECTION I: Safety Information........................................................................................ 3 SECTION II: Fireplace Preparation/Solid Fuel Burning Fireplace (FP)........................... 6 Fireplace Clearances(FP) .................................................................................................... 7 Gas Connection............................................................................................................
Streszczenie treści zawartej na stronie nr. 4
Streszczenie treści zawartej na stronie nr. 5
SECTION I SAFETY INFORMATION WARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THE APPLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get f
Streszczenie treści zawartej na stronie nr. 6
5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shut off gas supply. - Do not try to light any appliance. - Do not touch any electrical switch; do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire department. 7
Streszczenie treści zawartej na stronie nr. 7
21. All heater screens must be kept closed when operating the gas logs. 22. ”WARNING: Failure to keep the primary air opening (s) of the burner (s) clean may result in sooting and property damage.” 23. Do not use this heater for burning trash or cooking. Never place matches, paper, garbage, or any other material on top of logs or into the flames. 24. Do not install or operate this heater in areas where impurities in the air exist (such as tobacco smoke
Streszczenie treści zawartej na stronie nr. 8
SECTION II FIREPLACE PREPARATION The fireplace needs to be prepared before installing the heater. A. Turn off the gas supply to the fireplace. WARNING: BEFORE INSTALLING IN A SOLID-FUEL BURNING FIREPLACE, THE CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, ASHES, AND LOOSE PAINT BY A QUALIFIED CHIMNEY CLEANER. “WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE. AVOID DRAFTS THAT ALTER BURNER FLAME PATTERNS.” “WARNING: DO NOT USE A BLOWER
Streszczenie treści zawartej na stronie nr. 9
INSTALLATION AND CLEARANCES To ensure a safe installation into a masonry or factory built fireplace, the following instructions must be carefully followed: (1) Sidewall Clearances: Clearance from the side of the fireplace opening to any adjacent combustible wall should not be less than: right side 7", left side 7". (2) Ceiling Clearances: The ceiling height should not be less than 24" from the top of the fireplace opening. (3) Mantel Clearances: Clearances from top of heat
Streszczenie treści zawartej na stronie nr. 10
CR3329 CERAMIC LOG SET PLACEMENT, FOR MODEL 34 (3) (4) (2) (1-R) (1-L) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. WA
Streszczenie treści zawartej na stronie nr. 11
EMBER STOVE LOG SET PLACEMENT FOR MODEL 34 4 3 1 2 6 5 7 “MILLIVOLT ONLY” WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. WARNING: POSITIONING OF LOGS IS VERY
Streszczenie treści zawartej na stronie nr. 12
GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is as shown in the table below. NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT GAS PRESSURE CHECK Millivolt, and the left side for SIT Modulating. The appliance and its appliance main gas valve must be disconnected from the gas supply Check the inlet pressure to the burner to ensure that it is as shown in the table below. piping system during any pressure tes
Streszczenie treści zawartej na stronie nr. 13
LIGHTING INSTRUCTIONS MILLIVOLT VALVE (ITT) FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell around the appliance for gas. Be sure to smell next to the floor because gas is heavier than air and
Streszczenie treści zawartej na stronie nr. 14
50 60 70 80 90 ON OFF ON PRESS LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on previous page. 2. Make sure the manual shutoff valve is fully closed.If equipped with thermostat set to the lowest setting. 3. Turn off all electrical power to the appliance. 4. Open access panel door located at bottom front of the appliance. 5. Turn control knob clockwise to the full “OFF” position. ROCKER SWITCH ITT VALVE IGNITOR ELECTRODE PILOT BURNER PIEZO THERMOGENERA
Streszczenie treści zawartej na stronie nr. 15
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. IGNITOR ELECTRODE PILOT BURNER THERMO-COUPLE THERMO-PILE 12. Turn control knob counterclockwise to the “ON” position. Push the “ON/OFF” toggle switch to the “ON” position. The main burner should light. 13. Close access panel door. 14. Turn on all electrical power to the appliance. NOTE: This unit may be used with an
Streszczenie treści zawartej na stronie nr. 16
THERMOSTAT CONTROL OPERATION • This valve operates off of millivolts produced by the generator. You may choose to use an optional Wall Thermostat or Remote control. If so, see page 22 for wiring diagram. MANUAL LIGHTING PROCEDURE 1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod. 2. Open access panel door located at bottom front of the appliance. 3. Place the match in the holder and light. With the le
Streszczenie treści zawartej na stronie nr. 17
LIGHTING INSTRUCTION MODULATING VALVE (SIT) MANUAL VALVE (SIT) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.” A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the fl
Streszczenie treści zawartej na stronie nr. 18
LIGHTING INSTRUCTION 1. STOP! Read the safety information on preceding page 15. 2. Make sure manual shutoff valve is fully closed. 3. Turn off all electrical power to the appliance. 4. Open access panel door located at bottom front of the appliance. 5. Turn control knob clockwise to the full “OFF” position. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follo
Streszczenie treści zawartej na stronie nr. 19
11. Turn gas control knob counterclockwise to “ON” position. Continue to turn the gas control knob counterclockwise to your desired setting. 12. Close access panel door. 13. Turn on all electrical power to the appliance. CAUTION DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF VALVE. TO TURN OFF GAS TO APPLIANCE SHUTTING OFF UNIT 1. Open access cover door. 2. Turn gas control knob clockwise
Streszczenie treści zawartej na stronie nr. 20
THERMOSTAT CONTROL OPERATION 1. The thermostat control on this heater differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature and adjusts the amount of gas flow to the burner. This will increase or decrease the flame height. At times, the room may exceed the set temperature, which will cause the burner to shut off. When room temperature drops below the thermostat setting, the burner wil