Streszczenie treści zawartej na stronie nr. 1
CARE AND OPERATION INSTRUCTIONS
Direct-Vent Gas
Fireplace Heater Inserts
P/N 775,157M Rev. J, 12/2007
Installer: Leave This Manual With The Appliance.
Consumer: Retain This Manual For Future Reference.
A French manual is available upon request. Order P/N 775,157CF.
US
Models: EDVI25, EDVI30 & EDVI35
Ce manuel d’installation est disponible en francais, simplement
en faire la demande. Numéro de la pièce 775,157CF. Report No. 116-F-14-5
WARNINGS
• Hot! Do not touch! The glass and surfaces
Streszczenie treści zawartej na stronie nr. 2
IMPORTANT SAFETY AND WARNING WARNING WARNING INFORMATION Carbon Monoxide Poisoning: Do not use these appliances if Early signs of carbon monoxide any part has been under water. READ THIS MANUAL IN ITS poisoning are similar to the flu Immediately call a qualified, ENTIRETY AND UNDER-STAND with headaches, dizziness and/or professional service technician THESE RULES TO FOLLOW FOR nausea. If you have these signs, to inspect the appliances and to SAFETY. obtain fresh air i
Streszczenie treści zawartej na stronie nr. 3
Input of millivolt models is variable. These rates CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU- areshown in the following table: FACTURED BY LENNOX HEARTH PRODUCTS. When you purchased your new gas-fired heater, you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for Millivolt Models with efficiency and our environment. We extend our continued support to help you achieve MAnnually-Modulated Gas Val
Streszczenie treści zawartej na stronie nr. 4
T O O W O L I P O N O L T H N GAS CONTROLS CONTROL COMPARTMENT ACCESS Test gauge connections are provided on the front of the millivolt gas control valve (identi- Pull down hinged door to access control fied IN for the inlet and OUT for the manifold See Figure 3, showing how to access the compartment (see Figure 3). control compartment. side).See Figures 1 & 2. These millivolt appliances are fitted with a burner Control Compartment Access This
Streszczenie treści zawartej na stronie nr. 5
OPERATION AND CARE OF YOUR APPLIANCE WARNING IMPORTANT Turn off gas and electrical power Do not use abrasive cleaners Appliance operation may be controlled through a remotely located optional wall thermostat or before servicing the appliance. on glass. Never clean the glass remote control. when it is hot. In lieu of remote control or remote wall thermo- CAUTION stat operation, the appliance must be operated WARNING directly through the on/off
Streszczenie treści zawartej na stronie nr. 6
TH TH TP TP 8. (EDVI30 only) Remove the two screws 14.(EDVI35 only) Remove the blower per Small Area Paint Touch-up shown in Figure 7, then lift out air hood. instruction in Figures 12 through 14. The finish of the insert body and surround (optional) is a high-quality powdercoat. Only use factory supplied powdercoat paint for Air Hood touch-ups, cat.no. 90L74. Do not attempt to repaint the insert until the finish is completely cured
Streszczenie treści zawartej na stronie nr. 7
MAINTENANCE SCHEDULE Annually (Beforethe onset of the Burning Season) Maintenance Task Accomplishing Person Procedure Inspecting/Cleaning Burner,Logs Qualified ServiceT echnician Inspect valve and ensure it is properly operating. Check piping and Controls for leaks. Vacuum the control compartment, fireplace logs and burner area. Check Flame Patterns and Flame Qualified Service Technician Refer to Figure 19 on Page 8 and verify the flame pattern He
Streszczenie treści zawartej na stronie nr. 8
TopLouver Top Surround PROCEDURE FOR REMOVING THE STANDARD GLASS DOOR ASSEMBLY WARNING Handle glass door with extreme care! The glass Figure 18 Lift top of door off this flange door assembly is susceptible to damage. Do not scratch while handling or while reinstalling. To reinstall glass door assembly panel, reverse instructions 1 - 3 on thispage. WARNING BURNER ADJUSTMENT Never operate unit without the front glass door Flame Appearance and Sooting panel i
Streszczenie treści zawartej na stronie nr. 9
Burner Adjustment Procedure CAUTION WARNING Carbon will be produced if the air shutter is closed too much. Any damage due to carboning resulting from improperly setting the air Air shutter adjustment should shutter is not covered under the warranty. only be performed by a qualified professional service technician. The following chart (Table 5) is provided to aid you in achieving the correct air shutter adjustment for your installation. CAUTION Air Shutter Adj
Streszczenie treści zawartej na stronie nr. 10
1. Place the rear log onto the two corresponding locating pins at the back of the fireboxas shown in Figure 22. Figure 25 Front Left Log 5. Install the Top Left Log onto the corresponding locating pin and Rear Log Figure 22 indentation on Center Log as shown in Figure 26. . Place the Front Right Log onto the two corresponding locating pins as shownin Figure 23. Figure 26 TopLeft Log 6. Install the Front Center Log over the Front
Streszczenie treści zawartej na stronie nr. 11
Embers Figure 29 Figure 28 TopRight Log 8. Placethe glowing embers on the burner as shown in Figure 29. One package of ember material has been included with this log set You willnot need to usethe entire bag. IMPORTANT: The quantity and placement of the ember material can affect insert performance therefore it is very important that it be placed as shown in Figure 29. a. Unpackage and divide the fine ember material (mineral wool) into dime-sizedfl
Streszczenie treści zawartej na stronie nr. 12
Carefully install the seven-piece log set into the firebox as shown in 5. Place the Front Center Log in place as shown in Figure 35. The these instructions. All logs should fit onto corresponding pins and/or backof the log fits into thecorresponding indent on Rear Log. log stoppers. Thiswill ensure aproper flame andsafe combustion. 1. Place some vermiculite around the burner as shown in Figure 32 (the entire bag of vermiculite will N
Streszczenie treści zawartej na stronie nr. 13
MILLIVOLT APPLIANCE CHECKOUT FIREPLACE REQUIREMENTS Room Air Circulation Blower IMPORTANT: When installing these appliances Light the pilot by following the instructions IMPORTANT: Blower ground wire with into a factory built fireplaces or heatforms, the Pages 16 or 17 ofthis manual. power cord green wire should be attached air flow within and around the fireplace shall not to the ground screw. Failure to do so will be altered by the installation of th
Streszczenie treści zawartej na stronie nr. 14
TH TH TP TP P A Deluxe Remote Control System Screen Door Kits SIT & Honeywell Millivolt Wiring Diagram The Model RCL-T (Deluxe) Remote Control These decorative screen door panels fit over System has all of the features of the standard the standard glass door panels. If any of the original wire as supplied must be system along with an added easy to read LCD replaced, it must be replaced with Type AWM screen which presents access to many enhance- 105° C - 18
Streszczenie treści zawartej na stronie nr. 15
Width ACCESSORY COMPONENTS Surround Kits Hearth Riser Kits These surround panels install around the insert Wall Thermostat The hearth riser trim kits are designed to be bodyproviding an attractive finished look. used with the optional surround kits (sold The wall thermostat kit provides temperature separately). It provides a finished look below controlfor optimum comfort. the insert face when installed into fireplaces with a elevated firebox. S
Streszczenie treści zawartej na stronie nr. 16
T O O W O L I P O N O L T H N LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with a piezo • Donot use any phone in your building. igniter.When lightingthe pilot, follow these instructions • Immediately call your gas supplier
Streszczenie treści zawartej na stronie nr. 17
T O O W O L I P O N O L T H N INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. • Appelez immédiatement votre compagnie de gaz en utilisant le télé- A. Cet appareilest muni d’une veilleuse qui doit être allumée av
Streszczenie treści zawartej na stronie nr. 18
REPLACEMENT PARTS LIST Gas Controls Item # Part/Cat. No. Description Where Used 1 67L70 Pilot Assembly, NG/LP All 67L68 Pilot Tube All 3 67L67 Thermocouple All 4 60J79 Thermopile (pilot generator) All 10a 10K86 Piezo Igniter (wire not included) EDVI5 10b 4M89 Piezo Igniter (wire included) EDVI30 & EDVI35 7 67L87 Electrode Cable (piezo igniter wire w/ electrode) All 5a H1657 Gas Valve, NG – SIT EDVI5 5b H6196 Gas Valve, NG – Honeywell EDVI30 & EDVI35 Misc. Gas Components 6 H117 Burner Asse
Streszczenie treści zawartej na stronie nr. 19
T O O L I P O N O L REPLACEMENT PARTS DIAGRAMS 7 15 5a 5b 10b 8 11 19 9 3 3 4 1a 1 16 17 6 1b 0 18 1 16 3 10a 13 4 14 19 NOTE: DIAGRAMS &ILLUSTRA TIONSARE NOT TO SCALE I F H F
Streszczenie treści zawartej na stronie nr. 20
TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1) Spark igniter will not light A. Electrode wire (at Piezo Igniter) not pushed completely • Check connection pilot after repeated triggerin