Streszczenie treści zawartej na stronie nr. 1
Heat-N-Glo Fireplace
Installers Guide
Models:
U.S. Patents 4,793,322; 4,875,464; 5,000,162 and Patents Pending
8000 DVTFL
Canadian Patent 1,297,746
6000 DVTFL
Underwriters Laboratories Listed
6000 XLT
6000 ARCH
SL-42 DVT
READ THIS MANUAL BEFORE INSTALLING
WARNING
OR OPERATING THIS APPLIANCE. THIS
IF THE INFORMATION IN
INSTALLERS GUIDE MUST BE LEFT WITH
THESE INSTRUCTIONS IS
NOT FOLLOWED EXACTLY, A APPLIANCE FOR FUTURE REFERENCE.
FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY
WARNING: IMPROPER
D
Streszczenie treści zawartej na stronie nr. 2
SAFETY AND WARNING INFORMATION HEAT-N-GLO GAS FIREPLACE PRODUCTS LIMITED 10 YEAR WARRANTY In order to presumptively establish the dates to which your HEAT-N-GLO Limited 10 Year Warranty runs, you Highway 13, Savage, MN 55378, within 60 days of the date of fireplace installation. If you fail to do so, you must mail the completed warranty card to HEAT-N-GLO FIREPLACE PRODUCTS, INC., 6665 West The warranty exclusions and limitations of liability are effective upon installation of the fireplace. m
Streszczenie treści zawartej na stronie nr. 3
Safety and Warning Information ................... i Section 1: Approvals and Codes ................... 1 Approval Listings and Codes ............................ 1 Appliance Certification.................................. 1 Installation Codes .......................................... 1 High Altitude Installations ............................ 1 Table of Section 2: Getting Started ............................. 2 Contents Introducing the Heat-N-Glo Gas Fireplaces ...... 2 Pre-installation Prepara
Streszczenie treści zawartej na stronie nr. 4
Approval Listings Appliance Certification The Heat-N-Glo fireplace models discussed in this and Codes Installers Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICATION MODEL LABORATORY TYPE STANDARD 1 8000DVTFL Underwriters Direct Vent ANSI Z21.50•CGA2.22 Laboratories Decorative Approvals 6000DVTFL Underwriters Direct Vent ANSI Z21.50•CGA2.22 and Codes Laboratories Decorative 6000ARCH Underwriters Direct Vent ANSI Z21.50•CGA2.22 Laboratories De
Streszczenie treści zawartej na stronie nr. 5
Introducing the Heat-N-Glo direct vent gas fireplaces are designed to operate with all combustion air siphoned from outside Heat-N-Glo of the building and all exhaust gases expelled to the Gas Fireplaces outside. The information contained in this Installers Guide, unless noted otherwise, applies to all models and gas control systems. Gas fireplace diagrams, including the dimensions, are shown in this section. 2 Pre-installation This gas fireplace and its components are tested and Getting safe wh
Streszczenie treści zawartej na stronie nr. 6
When planning a fireplace installation, it’s necessary to determine: • Where the unit is to be installed. • The vent system configuration to be used. • Gas supply piping. • Electrical wiring. • Framing and finishing details. • Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired. If the fireplace is to be installed on carpeting or tile, or on any combustible material other than wood flooring, the fireplace should be installed on a metal or wood panel tha
Streszczenie treści zawartej na stronie nr. 7
Figure 2. Diagram of 6000DVTFL, 6000XLT and 6000ARCH 4
Streszczenie treści zawartej na stronie nr. 8
Figure 3. Diagram of SL-42DVT 5
Streszczenie treści zawartej na stronie nr. 9
Step 1 The diagram below shows space and clearance requirements for locating a fireplace within a room. Locating the Fireplace 3 Installing the Fireplace Figure 4. Fireplace Dimensions, Locations, and Space Requirements Clearance Requirements The top, back, and sides of the fireplace are defined by stand-offs. Minimum Clearances from the Fireplace to Combustible Materials Glass Back of Sides of Top of Front Floor Fireplace Fireplace Fireplace Ceiling 36 inches 0 1/2 inch 1/2 inch 3-1/2 inches 31
Streszczenie treści zawartej na stronie nr. 10
Minimum Clearances from the Vent Pipe to Combustible Materials For Vertical For Horizontal Sections Sections At Wall Firestops Top Bottom Sides Top Bottom Sides 3 inches 1 inch 1 inch 1 inch 2-1/2 inches 1/2 inch 1 inch (75 mm) (25 mm) (25 mm) (25 mm) (63.7 mm) (13 mm) (25 mm) For minimum clearances, see the direct vent termination clearance diagrams on pages 25 and 27 in this section. Step 2 Fireplace framing can be built before or after the fireplace is set in place. Framing should be position
Streszczenie treści zawartej na stronie nr. 11
Step 3 A. Vent System Approvals Models 8000DVTFL, 6000DVTFL, 6000XLT, and Installing the 6000ARCH are approved to use D-series direct vent Vent System pipe components and terminations. Model SL- 42DVT is approved to us SL-D-series components and terminations. Approved vent system components are labeled for identification. NO OTHER VENTING SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are included with each vent termination kit and should be used in conjunction with th
Streszczenie treści zawartej na stronie nr. 12
DV-45D DV-90D 67/16 65/32 81/2 8/12 11 5/8 11 1/16 73/8 57/8 61/2 51/16 85/8 85/8 11 15/16 DV-48D DV-36D 47 3/4 35 3/4 6-7/16" 6-5/32" (164 mm) (156 mm) 8-1/2" (216 mm) 8-1/2" 11-5/8" 11-1/16" (216 mm) 7-3/8" 5-7/8" (295 mm) (281 mm) 6-1/2" 5-1/16" (187 mm) (149 mm) (165 mm) (129 mm) 8-5/8" (220 mm) 8-5/8" 11-15/16" (220 mm) (303 mm) 47-3/4" (1.2 m) 35-3/4" (908 mm) DV-12D DV-09D DV-06D 11-3/4" 11 3/4 8-3/4" (298 mm) 8 3/4 5-3/4" 5 3/4 (222 mm) (146 mm) NOTE: PIPES OVERLAP 1 3/8 INCHES (
Streszczenie treści zawartej na stronie nr. 13
Figure 8. SL-D-Series Direct Vent Component Specifications (4-inch inner pipe/6 5/8-inch outer pipe) 10
Streszczenie treści zawartej na stronie nr. 14
VERTICAL VENTING NOTE: MODEL 6000 ARCH V (FT.) A 12-inch length of straight vent pipe MUST be 40' MAX. (12.4 M) the first vent component attached to the unit. CAP Figure 9. Vertical Venting 11 V
Streszczenie treści zawartej na stronie nr. 15
Model 6000XLT & 8000DVTFL VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) (8000 & 6000’s) H (FT.) SL-42DVT 1' MIN. (305 mm) 6' MAX. (1.86 m) 3’ MAX. (914mm) 2' MIN. (610 mm) 12' MAX. (3.66 m) 6’ MAX. (1.83m) 3' MIN. (914 mm) 18' MAX. (5.58 m) 9’ MAX. (2.74m) 4' MIN. (1.22 m) 24' MAX. (8.44 m) 12’ MAX. (3.66m) 20' MAX. (6.2 m) 24' MAX. (8.44 m) 12’ MAX. (3.66m) (21' IN CANADA 6.3 m) FOR SL-42DVT NOTE: IF A 90° ELBOW IS FIRST ATTACHED TO THE UNIT,
Streszczenie treści zawartej na stronie nr. 16
VENTING WITH TWO (2) 90° ELBOWS V (FT.) H + H (FT.) (8000 & 6000’s) H + H (FT.) (SL-42DVT) 1 1 1' MIN. (305 mm) 6' MAX. (1.86 m) 3' MAX. (914 mm) 2' MIN. (610 mm) 12' MAX. (3.72 m) 6' MAX. (1.83 m) 3' MIN. (914 mm) 18' MAX. (5.58 m) 9' MAX. (2.74 m) 4' MIN. (1.22 m) 24' MAX. (8.44 m) 12' MAX. (3.66 m) 20' MAX. (6.2 m) 24' MAX. (8.44 m) 12' MAX. (3.66 m) (21' IN CANADA 6.5 m) NOTE: MODEL 6000 ARCH A 12-inch length of straight
Streszczenie treści zawartej na stronie nr. 17
VENTING WITH TWO (2) 90° ELBOWS V (FT.) H (FT.) (8000 & 6000’s) H (FT.) (SL-42DVT) 1' MIN. (305 mm) 6' MAX. (1.6 m) 3' MAX. (914 mm) 2' MIN. (610 mm) 12' MAX. (3.72 m) 6' MAX. (1.86 m) 3' MIN. (914 mm) 18' MAX. (5.58 m) 9' MAX. (2.74 m) 4' MIN. (1.22 m) 24' MAX. (8.44 m) 12' MAX. (3.66 m) 24' MAX. (8.44 m) 12' MAX. (3.66 m) (21' IN CANADA 6.5 m) NOTE: V + V MAX. 20' (6.2 m) 1 NOTE: MODEL 6000 ARCH A 12-inch length of straight vent pipe MUST be the first vent component
Streszczenie treści zawartej na stronie nr. 18
VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) (8000 & 6000’s) H (FT.) (SL-42DVT) 1' MIN. (305 mm) 6' MAX. (1.86 m) 3' MAX. (914 mm) 2' MIN. (610 mm) 12' MAX. (3.72 m) 6' MAX. (1.86 m) 3' MIN. (914 mm) 18' MAX. (5.58 m) 9' MAX. (2.74 m) 4' MIN. (1.22 m) 24' MAX. (8.44 m) 12' MAX. (3.66 m) 24' MAX. (8.44 m) 12' MAX. (3.66m) NOTE: H + H1 MAX. 24' (8.44 m) (8000 & 6000’s) NOTE: H + H1 MAX. 12' (3.66 m) (SL-42DVT) MAX. 20
Streszczenie treści zawartej na stronie nr. 19
VENTING WITH THREE (3) 90° ELBOWS V (FT.) H + H (FT.) (8000 & 6000’s) H + H (FT.) (SL-42DVT) 1 1 1' MIN. (305 mm) 6' MAX. (1.86 m) 3' MAX. (914 mm) 2' MIN. (610 mm) 12' MAX. (3.72 m) 6' MAX. (1.86 m) 3' MIN. (914 mm) 18' MAX. (5.58 m) 9' MAX. (2.74 m) 4' MIN. (1.22 m) 24' MAX. (8.44 m) 12' MAX. (3.66 m) 24' MAX. (8.44 m) 12' MAX. (3.66 m) NOTE: V + V MAX. 20' (6.2 m) 1 V V 1 1 V H H H 1 1 Figure 14. Venting with three 90° elbows 16
Streszczenie treści zawartej na stronie nr. 20
B. Installing Vent Components 1. Attach the First Vent Component to the Starting Collars To attach the first vent component to the starting collars of the fireplace: • Apply a 3/8 inch (9.5 mm) bead of stove cement around the inner pipe fireplace starting collar. • Make sure that the fireplace rope gasket supplied with the fireplace seals between the first vent component and the outer fireplace wrap. • Lock the vent components into place by sliding the concentric pipe sections with four (4) equ