Streszczenie treści zawartej na stronie nr. 1
Installation & Operating Manual
The Harman Built Serenity III
HB 38 DV
“Ce manuel est disponible en Français sur demande”
R8
SAFETY NOTICE
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES
IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW
INSTALLATION DI
Streszczenie treści zawartej na stronie nr. 2
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. B. FOR YOUR SAFETY: WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Open windows. • Extinguish any open flame. • Do not touch any electrical switch; do not use any phone in
Streszczenie treści zawartej na stronie nr. 3
Table of Contents Introduction 4 Safety Precautions 4 Operation 6 Specifications 8 Installation 12 Arch Face 15 Victorian Face 16 Venting 20 Damper Settings 24 Changing to LP 25 Log Placement 27 Option Installation Thermostat 28 Remote Control 28 Remote Register Kit 29 Maintainence 35 Wiring Diagram 37 Trouble Shooting 41 Warranty 46 Manufactured by The Harman Stove Company 352 Mountain House Rd. Halifax PA 17032 M:PM65-FILES\MANUALS\HBF\hb38dvR6.p65
Streszczenie treści zawartej na stronie nr. 4
Introduction sageways of the Serenity III be kept clean. The Harman Serenity III Direct Vent Gas Fire- place is a listed gas-fired direct vent room fireplace tested When operating your Harman Serenity III Gas Fire- place, respect basic safety standards. Read these in- by Intertek Testing Services/Warnock Hersey to ANSI Z21.88-2002/ CSA2.33-M02. CAN-CGA-2.17- structions carefully before you attempt to operate the fireplace. Failure to do so may result in damage to prop- M91. The installation of
Streszczenie treści zawartej na stronie nr. 5
IMPORTANT FEATURE Air Gate Blower System Typically in gas fireplaces the blower (which is usually an option) is placed to blow air up the back of the firebox without any method to keep the 200% To 300% air pressure from being lost. This method allows air to flow freely around the blower when the blower is More Air off but gives up a large percentage of the blowers efficiency when it is on. The Air Gate Blower System gives you the best of both worlds. Blower Off When the blower is off the air gat
Streszczenie treści zawartej na stronie nr. 6
OPERATION Operation HOW TO LIGHT THE FIRE High-Low 1. STOP! Read the safety information on the Gas Control front cover. 2. If using the optional thermostat, set thermostat to the lowest setting. 3. Turn off electric power to the appliance. 4. Turn the ON-OFF/THERMOSTAT switch to the OFF position. 5. Push in the gas control knob slightly and turn it clockwise to "OFF." NOTE: THE KNOB CANNOT BE TURNED FROM "PILOT" TO "OFF" UNLESS IT IS PUSHED IN SLIGHTLY. DO NOT FORCE IT. 6. Wait five (5)
Streszczenie treści zawartej na stronie nr. 7
OPERATION room temperature. Bottom rear view of burner module. 15. Set the High-Low Regulator to desired setting: Turn fully counterclockwise for High and fully clockwise for Low. 16. Press the rear burner switch to the “ON” or “OFF” position as desired. This switch will return to the center position after it is pressed. This is normal as well as a faint click when pressed. The main burner must be lit before the rear burner will light. The rear burner may be turned “ON” or “OFF” at any time. Rea
Streszczenie treści zawartej na stronie nr. 8
SPECIFICATIONS Top Standoffs Vent Collar Accordion Heat Exchanger Glass Door Brick Burner Module Electrical Box On-Off- Thermostat Switch Blower Speed Switch Ignitor Battery On-Off-Pilot Knob Pack Blower Rear Burner Hi-Low Knob Switch Top Vent Rear Vent RATINGS NATURAL PROPANE NATURAL PROPANE Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m) 43500 43500 41500 41400 Min. Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m) 23300 23800 22800 23400 Orifices (DMS)(front/rear)(0-4500 ft.)(0-1375 m) 31/51 52/59 32/5
Streszczenie treści zawartej na stronie nr. 9
SPECIFICATIONS MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION Unit to floor 0 in. Face to side wall 7 in. Unit to top stand-offs 0 in. Unit to side stand-offs 0 in. Unit to rear stand-offs 0 in. Top of Glass to 7” Mantel 26in. Electrical Rating: 120 Volts, 60 Hs, >2.75 AMP This fireplace may be placed on a wood floor. Must be Noncombustible 1 2 Optional Arch Hood Hearth is not required in front of the fireplace 1. Clearance from top of glass to 7” mantel. 26 inches 2. Clearance from top of ac
Streszczenie treści zawartej na stronie nr. 10
SPECIFICATIONS Rear Vent Corner 1 1” 70” Elictrical Hook-up Gas In 10
Streszczenie treści zawartej na stronie nr. 11
SPECIFICATIONS Top Vent Corner 64” Elictrical Hook-up Gas In 11
Streszczenie treści zawartej na stronie nr. 12
Only For Qualified Installers INSTALLATION Installation Options This section deals with basic installation of and Arch face and a Victorian face. It does not describe every possible way to install this fireplace. This is why it is important to have a qualified installer do the installation. The Serenity III can be laid in stone, brick, or other masonry products. For this purpose a special template face ( part # 1-00-4238231 ) is available. We also offer a line of Harman Built mantels, mantel cab
Streszczenie treści zawartej na stronie nr. 13
Only For Qualified Installers INSTALLATION This appliance must be electrically connected and Placement grounded in accordance with local codes or , in the Here are some of the things that will effect the absense of local codes, with the current edition of exact placement of the fireplace. NFPA 70-National Electric Code or CSA C22.1- 1. Top or rear flue Canadian Electrical Code. 2. Arch face or mantle face. Arch face - Must decide on mantel and front This unit shall not be installed on carpet, vi
Streszczenie treści zawartej na stronie nr. 14
Only For Qualified Installers INSTALLATION Installing fireplace in a wall with an arch face, ceramic tile facing, and a face mantel. Noncombustible 1 inch thick Noncombustible material such as Dura-rock must be used A one inch space under the front edge of the fireplace as facing on the front of the fireplace cabinet. allows room for hearth material. Hearth material that is thicker must be compensated for by raising the fireplace the proper amount. Ceramic tile, marble or other decorative nonco
Streszczenie treści zawartej na stronie nr. 15
Only For Qualified Installers INSTALLATION Installing The Arch Face To install the arch face, place the hooks on the bottom rear of the face into the hook slots on the Latch Handles fireplace. Next with the top latches handles in the horizontal position push the face against the fire- place and swing the latches straight down causing them to enter the top face slots. Removing The Arch Face To remove the face, unlatch the top latches, tilt the top of the face away from the fireplace and lift the
Streszczenie treści zawartej na stronie nr. 16
Only For Qualified Installers INSTALLATION Assembling the Victorian Face 1. Position the mantel face down on the floor. 2. Place the left piller over the two studs on the left side of the mantel. Install two washers and nuts and tighten. 3. Place the left side of the breast plate into the slots on the left pillar. 4. Place the Left hinge pin of the top grill door into the round hole in the pillar. 5. Place the left hinge pin of the bottom grill door into the round hole in the bottom of the pilla
Streszczenie treści zawartej na stronie nr. 17
Only For Qualified Installers INSTALLATION Installing Fireplace To use Drywall Bracket Victorian Face Nails When installing the fireplace to use the Victo- rian Face the unit must be positioned back 1/2 inch farther than with an arch face. A special drywall Nails bracket must be used to allow the drywall to extend down far enough so the face will cover the drywall. 1. Install drywall bracket on top of the stand-offs with two screws. 2. Place the fireplace into the framed opening so the two ends
Streszczenie treści zawartej na stronie nr. 18
Only For Qualified Installers INSTALLATION Mounting The Victorian Face 1. Place fiberglass rope in sealing angle with angle mounting bolts loose. 2. Place the face on the fireplace starting at the bottom. 3. Slide the face into place and install the four bolts as shown at left. 4. Slide the sealing angle against the fireplace and tighten the mounting bolts. Mounting Holes Note: The face will have a one inch space under it for hearth material. This must be considered when planning the installatio
Streszczenie treści zawartej na stronie nr. 19
Only For Qualified Installers INSTALLATION Burn Only the Fuel for which the Heater is Natural Gas: Equipped Maximum inlet pressure 7.0" w.c. (1.74 kPa) The Serenity III Direct Vent will burn either Minimum inlet pressure 5.0" w.c. (1.25 kPa) natural gas or propane, but requires a change over Gas manifold pressure 3.5" w.c. (0.87 kPa) kit for propane. The label on the burner system mod- LPG Gas: ule indicates the fuel for which it is equipped. A sec- Maximum inlet pressure 13" w.c. (3.24 kPa) ond
Streszczenie treści zawartej na stronie nr. 20
Only For Qualified Installers VENTING Use Only Approved Venting This appliance has been tested and is listed for installation with Simpson Duravent GS venting com- ponents. The Simpson Duravent GS warranty will be voided, and serious fire, health, or other safety hazards may result from any of the following actions: • Installation of any damaged Duravent GS component. • Unauthorized modification of the Duravent GS System. • Installation of any component part not manufactured or approved by Simps