Streszczenie treści zawartej na stronie nr. 1
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Sonnet
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your
Streszczenie treści zawartej na stronie nr. 2
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, if the pilot or pilot and in accordance with their instructions. Carefully read all burners have gone out on their own, open the the instructions in this manual first. Consult the building glass door and wait 5 minutes to air out before authority having jurisdiction to determine the need for a
Streszczenie treści zawartej na stronie nr. 3
Table of Contents Safety Precautions...........................................................................................................2 Table of Contents.............................................................................................................3 Codes And Approvals.......................................................................................................4 Specifications.........................................................................................
Streszczenie treści zawartej na stronie nr. 4
Codes And Approvals DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level. BV: This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L vent. May also be vented through a conventional chimney using a chimn
Streszczenie treści zawartej na stronie nr. 5
Specifications RATING LABEL LOCATION: The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the fireplace. DIMENSIONS: 3 17 / 4 " (451mm) 7 8 / 8 " (225mm) 1 2 / 4 " (57mm) 15 13 / 16 " (355mm) Sonnet T op without a T rim Installed 15 3 10 / 16 " 13 / 16 " (278mm) (336mm) 1 24 / 16 " (612mm) Sonnet T op with 5 12 / 16 " Colonial T rim Installed (312mm) 1 8 / 2 " (216mm) 13 1 13 / 16 " 31 / 4 " (350mm) (794mm) 3 1 1 3 23 / 16 " 1 1 /
Streszczenie treści zawartej na stronie nr. 6
Specifications 7 31 / 8 ” (809mm) to 403⁄4” (1035mm) 311⁄4” (794mm) 13 21 / 16 ” (555mm) 5 to 26 / 16 ” (669mm) 13 20 / 16 ” (528mm) 7 22 / 16 ” (569mm) 23” (583mm) Figure 2: Sonnet Adjustable Surround, Classic, and Base Shelf with Riser. Table 1: Sonnet Options Dimensions. Colonial - 3 Sided Colonial - 4 Sided Classic - 3 Sided Classic - 4 Sided 13 9 13 9 Height 20 /16” (528mm) 24 /16” (624mm) 20 /16” (528mm) 24 /16” (624mm) Width 311⁄4” (794mm) 311⁄4” (794mm) 311⁄4” (794mm) 311⁄4” (794mm) Adju
Streszczenie treści zawartej na stronie nr. 7
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. LIGHTING AND TURNING OFF INSTRUCTIONS: Hot while operating. Do not touch, severe burns may result. Keep children, clothing, CAUTION: furniture, gasoline or other flammable vapors away . CAUTION: Do not operate this fireplace with the glass remov
Streszczenie treści zawartej na stronie nr. 8
Operating Instructions The Sonnet is designed to gradually lower or raise the flame as is needed in application. It normally does not just turn on and off. This is very dependant on the size of the room the unit is located in. During the first several operational cycles the electronics go through a learning process that establishes how the system will react to the environment it is in. It does so by determining the amount of time it takes for the temperature to rise 1°. It does this several
Streszczenie treści zawartej na stronie nr. 9
Operating Instructions TIMER MODE – (appliance must be in standby mode; pilot ignited): The Timer mode is normally programmed to have two (2) Periods: P1 and P2. Between these two (2) periods, a lower operating temperature (or pilot only) can be set. Note: that between those periods, if the thermostat is set to a certain minimum temp (example 58°F (14.5°C)), then the unit will modulate to maintain that temp. For to operate as a thermostat, TEMP must be set at 4
Streszczenie treści zawartej na stronie nr. 10
Operating Instructions NOTE: The remote handset control instructions are on inside of remote’s battery cover plate (see Figure 7). remote instructions on battery cover Figure 7. Remote Control Instruction. CONTROL PANEL: Press the larger flame to increase flame height. Press the smaller flame to decrease flame height. For fine adjustment tap the appropriate flame icon, refer to Figure 4. Can also be use to turn unit on or off. BLOWER SPEED: The blower will come on only when the fireplace is up
Streszczenie treści zawartej na stronie nr. 11
Maintenance And Service Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance, may result in property damage or personal injury. At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or
Streszczenie treści zawartej na stronie nr. 12
Maintenance And Service GLASS DOOR REMOVAL: Remove the glass door by placing the hooked end of the door release tool in the hole on the door latch mechanism (see Figure 10) and pulling the latch out then up over the lip on the door. When the two (2) latches have been released, tilt the door forward and then lift up to unhook the bottom door tabs (see Figure 11). Figure 10: Door Release. Warning: Do not touch or attempt to remove the glass if the fireplace is not completely cold. Never o
Streszczenie treści zawartej na stronie nr. 13
Maintenance And Service CHANGING REMOTE HANDSET CODE & RESETTING RECEIVER: A code is preset for the remote handset and receiver, but can be changed if required. If one or more Sonnets are to be installed, confirm that the remote control signal codes are different for each unit.To change the code, complete the following: 1. Change DIP switch position (shown at the top of Figure 13). 2. Press and hold the receiver’s reset button (see Figure 14) until you hear two (2) acoustic signals. After the
Streszczenie treści zawartej na stronie nr. 14
Maintenance And Service REMOVING VALVE COVER: The valve cover can be removed to access the gas valve, the fan, wiring harness, or other components. 1. Remove the glass door as shown in the MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL. 2. Carefully remove the log set, ember material, and brick panels, refer to SECONDARY INSTALLATION - BRICK PANEL INSTALLATION and SECONDARY INSTALLATION - LOG SET AND EMBER INSTALLATION. Figure 17: Screws Holding Burner Tray in Place. 3. Using a T-20 screwdr
Streszczenie treści zawartej na stronie nr. 15
Maintenance And Service Kit Parts List: 1 - Orifice (Natural Gas #42 DMS or Propane #54 DMS) 1 - Conversion label 1 - Installation instruction sheet Carefully inspect the orifice supplied with this conversion kit. If it has been damaged or is missing, contact your dealer, distributor or courier company to have them replaced before starting this installation. Conversion Kit Installation: 1. Shut the gas supply off at the shut-off valve upstream of the unit. CAUTION: The gas supply mus
Streszczenie treści zawartej na stronie nr. 16
Maintenance And Service d) Turn the pilot head a 1⁄4 turn clockwise; back to its original position. e) Close the front of the pilot shield. 7. Convert the gas regulator: a) If unit is installed, pull the Sonnet out from the fireplace. LPG NG Ensure you do not damage any of the venting or the unit itself. 7 b) Using a /8” wrench, remove the brass nut at the back left of the unit (shown in Figure 27). A small black spring depressor is clipped into the back of the brass nut. Figure 26: Set
Streszczenie treści zawartej na stronie nr. 17
Initial Installation WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. CLEARANCES TO COMBUSTIBLES: Maintain sufficient clearances for operation, service and maintenance. • A clearance of 71⁄2” (191 mm) minimum is required from the side of the unit to the sidewalls. • A clearance of 41⁄2” (114 mm) minimum is required from the side of the unit to a 6” (152 mm) deep post/colum
Streszczenie treści zawartej na stronie nr. 18
Initial Installation QUALIFIED INSTALLERS ONLY B-VENT MODEL: WARNING: This appliance has been designed to operate by drawing combustion air and dilution air from the room. It is also designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying these openings in any way can create hazardous situations, either through poor venting or by overheating. It is important that this unit has sufficient air circulation for proper venting and combustion. Provis
Streszczenie treści zawartej na stronie nr. 19
Initial Installation QUALIFIED INSTALLERS ONLY • Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes or dirt being blown into the room and may cause a fire leading to death or serious injury. • If one or more Sonnets are to be installed, confirm that the remote control signal codes are different for each unit, refer to MAINTENANCE AND SERVICE - CHANGING REMOTE HANDSET CODE. 1. Remove the unit from the box and remove all packaging material fr
Streszczenie treści zawartej na stronie nr. 20
Initial Installation QUALIFIED INSTALLERS ONLY Figure 33: Spill Switch Wires Fed Figure 32: Install of Intake Air Plug. Through Back Panel. 2. Install spill switch assembly. a) Use a flat head screwdriver or 1⁄4” socket to remove the nine (9) screws holding the back cover on (see Figure 46). b) Cut the tie strap from around the wires for the spill switch. c) Feed the connector end of both wires through the hole in the bottom left corner of the back panel (see Figure 33). d) Using ne