Streszczenie treści zawartej na stronie nr. 1
UNVENTED (VENT-FREE)
PROPANE/LP GAS FIREPLACE
This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
OWNER’S OPERATION AND INSTALLATION MANUAL
CGF265PVA
AND
CGF280PT
Shown with optional
cabinet mantel and
®
hearth base.
WARNING: Improper installation,
WARNING: If the information in this manual is not
adjustment, alteration, service,
followed ex
Streszczenie treści zawartej na stronie nr. 2
SECTION PAGE CONTENTS Safety Information ................................................................................... 2 Product Identification .............................................................................. 4 Local Codes ............................................................................................. 5 Unpacking................................................................................................ 5 Product Features ....................................
Streszczenie treści zawartej na stronie nr. 3
WARNINGS Continued WARNING ICON G 001 SAFETY WARNING: Any change to this fireplace or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This INFORMATION appliance is not convertible for use with other gases. Continued 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical
Streszczenie treści zawartej na stronie nr. 4
PRODUCT Front Log (#1) Rear Log (#2) IDENTIFICATION Front Burner Rear Burner Left Front Branch (#4) Gas Regulator Base Right Front Branch (#5) Figure 1 - Log Base Assembly Top Louvered Top Outer Hood Casing Firebox Support Rear Access Door Screen Side Assembly Access Door Bottom Louver Assembly Figure 2 - Fireplace 4 102665
Streszczenie treści zawartej na stronie nr. 5
Install and use fireplace with care. Follow all local codes. In the absence of local LOCAL CODES codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 1. Place the carton containing the fireplace unit on its back. Hold fireplace and UNPACKING pull the carton and pallet away. Remove tr
Streszczenie treści zawartej na stronie nr. 6
AIR FOR WARNING WARNING ICON G 001 COMBUSTION This heater shall not be installed in a confined space unless provi- sions are provided for adequate combustion and ventilation air. AND Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. VENTILATION Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and cau
Streszczenie treści zawartej na stronie nr. 7
DETERMINING AIR FLOW FOR FIREPLACE LOCATION AIR FOR Determining if You Have a Confined or Unconfined Space COMBUSTION Use this work sheet to determine if you have a confined or unconfined space. AND Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. VENTILATION 1. Determine the volume of the space (length x width x height). Continued Length x Width x Height = ___________________ cu. ft. (volume
Streszczenie treści zawartej na stronie nr. 8
AIR FOR WARNING WARNING ICON G 001 COMBUSTION If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- AND tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3. VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provid
Streszczenie treści zawartej na stronie nr. 9
INSTALLING NOTICE A qualified service person must install fireplace. Follow all local codes. WARNING WARNING ICON G 001 Never install the fireplace • in a bedroom or bathroom • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas CAUTION WARNING ICON G 001 This fireplace creates warm air currents. These currents move heat to wall surfa
Streszczenie treści zawartej na stronie nr. 10
ASSEMBLING AND ATTACHING BRASS TRIM INSTALLING Note: The instructions below show assembling and attaching brass trim to fireplace. Continued Do not yet install brass trim if performing a built-in installation (See Built-In Fireplace Installation, page 13). 1. Remove packaging from three pieces of brass trim. 2. Locate four brass screws, two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 5. 4. Slide one end of adjusti
Streszczenie treści zawartej na stronie nr. 11
INSTALLATION CLEARANCES INSTALLING Continued WARNING WARNING ICON G 001 Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall. Carefully follow the instructions below. This will ensure safe installation. Minimum Wall and Ceiling Clearances (see Figure 7) A. Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches for a cabinet mantel or 12 inches for a corner installation. B. Clearances f
Streszczenie treści zawartej na stronie nr. 12
2. Break off nailing flanges (see Figure 8) with hammer or pliers. INSTALLING 3. Place mantel and base in desired location. Place heater in front opening of mantel. Make sure all pieces fit properly. Remove mantel. Continued 4. Mark floor and base or wall for gas line entrance. Make sure there is enough clearance between heater and mantel for gas line. IMPORTANT: Make sure there are no electrical lines where gas piping will go through floor or wall. Nailing Flanges Figure 8 - Location of Nailing
Streszczenie treści zawartej na stronie nr. 13
8. Connect fireplace to gas supply (see page 17). INSTALLING 9. Check all gas connections for leaks. See Checking Gas Connections, page 18. Continued 10. After heater is secured, replace mantel on hearth base (see Figure 11). Make sure mantel is flush against wall. Install brass trim (see page 11). Cabinet Mantel Figure 11 - Installing Cabinet Mantel BUILT-IN FIREPLACE INSTALLATION Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the fr
Streszczenie treści zawartej na stronie nr. 14
If installing in a corner, use dimensions shown in Figure 13 for the rough opening. INSTALLING The height is 33" which is the same as the wall opening, on page 13. Continued 39 3/8" 27 7/8" 35 1/2" 55 5/8" Figure 13 - Rough Opening for Installing in Corner 2. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See In
Streszczenie treści zawartej na stronie nr. 15
Mantel Clearances for Built-In Installation INSTALLING If placing mantel above built-in fireplace, you must meet minimum clearance Continued between mantel shelf and top of fireplace opening. Mantel Shelf 10" Underside of 8" Mantel Shelf 6" 1 2 /2" All minimum distances are in inches 1 1 20" 24 /2" 27 /2" 30" Top of Fireplace Opening Distances to Underside of Mantel Figure 15 - Minimum Mantel Clearances for Built-In Installation If your installation does not meet the above minimum clearanc
Streszczenie treści zawartej na stronie nr. 16
The installer must supply an external regulator. The external regulator will reduce INSTALLING incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage Continued could occur. Install external regulator with the vent pointing down as shown in Figure 16. Pointing the vent down protects it from freezing rain or sleet. Propane/LP Supply Tank External Regulator Vent Pointing Down Figure 16 -
Streszczenie treści zawartej na stronie nr. 17
INSTALLING A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap* Continued Approved Flexible Gas Line From External Regulator (11" W.C. to 14" W.C. 3" Minimum Pressure) Sediment Trap Tee Joint Pipe Nipple Cap Figure 17 - Gas Connection * Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 38. CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • 5/16" hex socket wrench or nut-driver • Phillips screwdriver • sealant (resist
Streszczenie treści zawartej na stronie nr. 18
4. Route flexible gas line from manual shutoff valve into fireplace through side or rear INSTALLING access panel. Route flexible gas supply line through fireplace access door. Continued NOTICE Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility from the fire- place. The flexible gas supply line connection to the manual shutoff valve should be accessible. 5. Apply pipe joint sealant lightly to male threads of gas connector attached
Streszczenie treści zawartej na stronie nr. 19
Streszczenie treści zawartej na stronie nr. 20
INSTALLING LOGS INSTALLING Continued WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Slide front log (#1) into place behind front burner