Streszczenie treści zawartej na stronie nr. 1
OPERATION AND PARTS MANUAL
Submersible Pumps
Model S-500 Series
Revision #0 (10/01/04)
THIS MANUAL MUST ACCOMPANY
THE EQUIPMENT AT ALL TIMES.
Streszczenie treści zawartej na stronie nr. 2
HERE'S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING MULTIQUIP CORPORATE OFFICE 18910 Wilmington Ave. 800-421-1244 Carson, CA 90746 FAX: 310-537-3927 Email: mq@multiquip.com Internet: www.multiquip.com PARTS DEPARTMENT 800-427-1244 FAX: 800-672-7877 310-537-3700 FAX: 310-637-3284 MAYCO PARTS 800-306-2926 FAX: 800-672-7877 310-537-3700 FAX: 310-637-3284 SERVICE DEPARTMENT 800-421-1244 FAX: 310-537-4259 310-537-3700 TECHNICAL ASSISTANCE 800-478-1244 FAX: 310-631-5032
Streszczenie treści zawartej na stronie nr. 3
S-500 SERIES SUB. PUMP — TABLE OF CONTENTS Multiquip S-500 Series Submersible Pump Submersible Pumps Component Drawings Here's How To Get Help ............................................ 2 S-500P, S-500UL, S-500CE Pump Assembly ... 26-29 Table Of Contents ..................................................... 3 S-500P, S-500UL Electric Motor Assembly ....... 30-31 Parts Ordering Procedures ....................................... 4 S-500CE Electric Motor Assembly .................... 32-33 Safety
Streszczenie treści zawartej na stronie nr. 4
S-500 SERIES SUB. PUMP — PARTS ORDERING PROCEDURES When ordering parts, please supply the following information: ❒❒❒❒❒ Dealer account number ❒❒❒ Dealer name and address ❒❒ ❒❒❒ Shipping address (if different than billing address) ❒❒ ❒❒❒❒❒ Return fax number ❒❒❒❒❒ Applicable model number ❒❒❒❒❒ Quantity, part number and description of each part ❒❒❒❒❒ Specify preferred method of shipment: FedEx or UPS Ground Note: Unless otherwise indicated by customer, all FedEx or UPS Second Day or Third Day or
Streszczenie treści zawartej na stronie nr. 5
S-500 SERIES SUB. PUMP — SAFETY MESSAGE ALERT SYMBOLS FOR YOUR SAFETY AND THE SAFETY OF OTHERS! HAZARD SYMBOLS Safety precautions should be followed at all times when Rotating Parts operating this equipment. Failure to read and understand the Safety Messages and Operating Instructions could result in injury to yourself and others. NEVER operate equipment with covers, This Owner's Manual has been or guards removed. Keep fingers, hands, developed to provide complete hair and clothing away from
Streszczenie treści zawartej na stronie nr. 6
S-500 SERIES SUB. PUMP — RULES FOR SAFE OPERATION ALWAYS make sure submersible pump is grounded. CAUTION NEVER use gas piping as an electrical ground. Failure to follow instructions in this manual may lead to serious DO NOT place hands or fingers inside pump when pump is injury or even death! This equipment is to be operated by running. trained and qualified personnel only! This equipment is for ALWAYS make certain that the voltage supplied to the pump industrial use only. is correct. A
Streszczenie treści zawartej na stronie nr. 7
S-500 SERIES SUB. PUMP — RULES FOR SAFE OPERATION ALWAYS make sure that electrical circuits are properly . Emergencies grounded per the National Electrical Code (NEC) and ALWAYS know the location of the nearest fire extinguisher. local codes before operating pump. Severe injury or death by electrocution can result from operating an ungrounded pump. NEVER use this pump to remove water from a swimming pool when people are in the water. ALWAYS be sure the operator is familiar with proper
Streszczenie treści zawartej na stronie nr. 8
S-500 SERIES SUB. PUMP — DIMENSIONS Figure 1. S-500P, S-500UL Dimensions PAGE 8 — S-500 SERIES SUBMERSIBLE PUMPS — OPERATION & PARTS MANUAL — REV. #0 (10/01/04)
Streszczenie treści zawartej na stronie nr. 9
S-500 SERIES SUB. PUMP — SPECIFICATIONS TABLE 1. SPECIFICATIONS MP odel SL -500 S-500U Centrifugal Centrifugal Type Submersible Pump Submersible Pump Ir mpeller Rr ubbe Rubbe S) uction & Discharge Size2) .00 in. (51 mm 1.50 in. (38 mm 61 gallons/minute 63 gallons/minute Maximum Pumping Capacity (230 liters/minute) (238 liters/minute) MA ax. Solids Diameter NA / N/ M) ax Head 3) 4 ft. (10.4 meters 36 ft (11.0 meters P) ower 0) .5 HP (0.37kw 0.5 HP (0.37kw VV oltage Phase 1V Ø 115 1Ø 115 S4 tartin
Streszczenie treści zawartej na stronie nr. 10
S-500 SERIES SUB. PUMP — GENERAL INFORMATION If the pump was used to pump water containing mud, silt, use Introduction clean water to flush out the pump after each use. The Multiquip Model S-500 series submersible pumps are designed to pump water and is used for the draining (de- DO NOT allow the pump to run dry, as this will damage the watering) of swimming pools, well casings construction sites, pump. During maintenance, dry running is permissible but only cofferdams, manholes, transformer vau
Streszczenie treści zawartej na stronie nr. 11
S-500 SERIES SUB. PUMP — COMPONENTS Figure 2. Submersible Pump Components Figure 2 shows the location of the basic components, for the 6. Carrying Handle – Always carry the submersible pump S-500 series submersible pumps. Listed below is a brief by its handle. NEVER! carry the pump by its power cord. explanation of each component. Carrying or lifting the pump by the power cord, will cause undue stress on the cord, and ultimately the cord will 1. Strainer Base – This strainer base is made of s
Streszczenie treści zawartej na stronie nr. 12
S-500 SERIES SUB. PUMP — FLOAT SWITCHES Design Features Float Switch Theory Constructed of rigid, durable ABS polymer ultrasonically welded. Mercury monitoring is a mercury-switch actuated, liquid level The all-steel mercury switch is held by positioning pins. Interior control that has proven to be more economical and longer lasting is filled with cell foam. than other types of liquid-level control systems, easily replacing and improving upon diaphragm switches, air bubble systems Suitable for
Streszczenie treści zawartej na stronie nr. 13
S-500 SERIES SUB. PUMP — FLOAT SWITCH (PIGGY-BACK) Float Switch Single or dual control float switches can be used for the unattended operation of the submersible pump. When using the piggy- back power configuration (plug), the S-500 series pumps DO NOT require the use of a control box. In this configuration (piggy-back), the SW-1 (single float switch) or SW-2 (dual float switch) are required. Figure 6 is an example of a single float switch application. Mounting The Float Switch Figure 6 shows
Streszczenie treści zawartej na stronie nr. 14
S-500 SERIES SUB. PUMP — FLOAT SWITCH (CONTROL BOX) Control Box (CB3) For special remote pumping applications of the submersible pump, a control box (Model CB3) may be required. This water resistant control box provides watertight housing and glands to prevent water from leaking into the box, and a float switch interface. When using the CB3 control box, only the SW-1WOP float switch (2) can be used (no plug, bare wires). Shown below (Figure 7) is a wiring layout of the CB3 control box. See pa
Streszczenie treści zawartej na stronie nr. 15
S-500 SERIES SUB. PUMP — OPERATION Hose Connections 1. Connect a 2-inch hose to the discharge port on the pump as shown in Figure 8. Make sure that the hose is attached correctly to the discharge port. Pump Power Connections (Piggy-Back Cord Only) 1. Make sure the circuit breaker supplying power to the pump is in the OFF position. 2. Connect the float switch or switches to the AC power receptacle as shown in Figure 6. Attaching Lifting Rope 1. Attach a suitable lifting cable (rope) to the carr
Streszczenie treści zawartej na stronie nr. 16
S-500 SERIES SUB. PUMP— CONTROL BOX INSTALLATION Power Cord Requirements DANGER When routing the 115 VAC, 60 Hz., single phase power via a power cord to the control box, ALWAYS use the correct wire size. The S-500 series submersible Please reference Table 4 below (Cord Length/Wire Size) to pumps are also designed to work determine the correct wire size. Incorrect wire size can adversely with a control box (Model CB3). This affect the performance of the pump. control box contains the necessar
Streszczenie treści zawartej na stronie nr. 17
S-500 SERIES SUB. PUMP— CONTROL BOX INSTALLATION 2. Remove the pump AC input connector housing from the Connecting AC Power to the Control Box control box, then route the power cord through the cable 1. The AC power cord (input) should have three wires. Each gland on the control box. wire is color coded. The colors are WHITE, BLACK and 3. Connect the pump power cord to the contactor as shown in GREEN. Figure 7 and Table 7. 2. Remove the AC input connector housing from the control box, then rou
Streszczenie treści zawartej na stronie nr. 18
S-500 SERIES SUB. PUMP — CLEAN-UP Pump Shut-Down/Clean-up 1. Remove the power from the pump by turning off the circuit breaker or switch that provides power to the pump. Remem- ber to make sure that hands are dry (not wet), and feet are not standing in water when removing disconnecting power from the pump. 2. Using the lifting rope, lift the pump up from its current position. Remove the discharge hose from the discharge port on the pump. 3. Remove all power cables and float switches from the con
Streszczenie treści zawartej na stronie nr. 19
S-500 SERIES SUB. PUMP — MAINTENANCE LUBRICATION 2. While checking the hydraulic oil level, also check the condition of the hydraulic oil in the seal cavity . Block the To check the oil level of the mechanical seal perform the opening with a finger and roll pump to one side to drain following: oil into a small transparent container. If oil is cloudy or has DISASSEMBLY water in it, drain oil from pump cavity and replace hydrau- lic oil. Check the seal for wear damage. Refer to Figure 11 for loca
Streszczenie treści zawartej na stronie nr. 20
S-500 SERIES SUB. PUMP — TROUBLESHOOTING Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 8 (Pump Troubleshooting) as a basic guideline for troubleshooting the pump. If the problem cannot be remedied, contact Multiquip's service department. TABLE 8. PUMP TROUBLESHOOTING SYMPTOM POSSIBLE PROBLEM SOLUTION Check that proper voltage (115 VAC, 60 Hz, single-phase ) is being supplied to the pump. Also check that the