Streszczenie treści zawartej na stronie nr. 1
READ AND SAVE THESE INSTRUCTIONS
™
ST CROIX
Damp Location
Ceiling Fan
Owner's Manual
Model Numbers
Blades & Downrod Kit Sold Separately
CF3300AP
Two Person Installation Required
Net Weight: 44.8 Lbs. CF3300ORH
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Cover
Streszczenie treści zawartej na stronie nr. 2
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
Streszczenie treści zawartej na stronie nr. 3
THIS FAN IS SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES, COVERED PATIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 One 1/4” blade screwdriver One wire stripper One 5/16” open end wrench or pliers ! WARNING 7/16”, 1/2” & 9/16” wrench or socket wrench One 1/4” drill bit Before you assemble your ceiling fan, refer to MATERIALS section on pr
Streszczenie treści zawartej na stronie nr. 4
F. DECORATIVE STRAP RING A. FAN D. UPPER ASSEMBLY M. SW22 DECORATIVE WALL DOWNROD SLEEVE OFF CONTROL B. FAN MOTOR C. DECORATIVE DOWNROD COVERS (2) SLEEVE ASSEMBLY H. RIGHT HAND M. MOUNTING BLADE FLANGES (4) BRACKET BAG I. LEFT HAND BLADE FLANGES (4) N. HARDWARE BAG G. CEILING CANOPY L. BLADE O. FLANGE MEDALLIONS (8) ASSEMBLY E. DOWNROD BAG EXTENSION K. HANGER BRACKET P. BLADE ASSEMBLY ASSEMBLY BAGS J. HANGER BALL/ DOWNROD Q. DOWNROD EXTENSION ASSEMBLY BAG How to Put Your C
Streszczenie treści zawartej na stronie nr. 5
7. Route the motor lead wires and support wire through the upper decorative downrod sleeve and DOWNROD the decorative strap ring (Figure 4). Careful not to 1/4 x 10mm ROUND scratch the downrod with the sleeve and ring HEAD SCREW (4) during installation. DOWNROD NOTE: Be careful not to scratch the downrod EXTENSION during installation. 8. Position the upper decorative downrod sleeve and the decorative strap ring just above the decorative downrod sleeve assembly during initial installation (Figu
Streszczenie treści zawartej na stronie nr. 6
10. Route the motor lead wires and support wire through the downrod extension and the hanger PIN ball (Figure 6). HANGER BALL 11. Securely attach the downrod to the downrod extension/hanger ball using the four 1/4 x 10mm DOWNROD SETSCREW EXTENSION round head screws (supplied in the downrod assembly bag) (Figure 6). The round head screws 1/4 x 10mm ROUND must be fully tightened into the downrod HEAD SCREW (4) DOWNROD extension. A loose downrod will result with fan assembly noise and vibration. C
Streszczenie treści zawartej na stronie nr. 7
1. Securely attach the ceiling support wire to the ! WARNING ceiling joist or structural member using the 3/8 x 2” hex lag bolt and flat washer. Drill a maximum Hanger bracket must seat firmly against outlet diameter 1/4” pilot hole into the supporting member box. If the outlet box is recessed, remove wall to prevent splitting or cracking. Install a washer board until bracket contacts box. If bracket onto the screw and insert the screw through one of and/or outlet box are not securely attached,
Streszczenie treści zawartej na stronie nr. 8
8. Insert the fan cable through the hole of the large 9. Full tighten the 5/32 phillips head screw on the brass barrel nut (supplied) and push it up the cable brass barrel nut to secure the fan cable in position. to within one inch of the small brass bushing. Pass Cut off and discard the excess fan cable protruding the free end of the cable back through the large from the brass barrel nut (Figure 9B). brass barrel nut in the opposite direction and remove as much slack as possible. LOOP THE CABLE
Streszczenie treści zawartej na stronie nr. 9
NOTE: Carefully remove the masking tape applied #10-32 X 18mm OVAL HEAD to the center hole of ceiling cover, still taking SCREWS (3 per flange) caution to not scratch downrod during MEDALLION installation. 3. Screw the two threaded studs (supplied) into the BLADE (sold separately) tapped holes in the hanger bracket. FLANGE 4. Lift the ceiling canopy up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 11). Figure 12 5. Secure the ceiling canop
Streszczenie treści zawartej na stronie nr. 10
5. Thread the fan motor cover onto the fan motor assembly threaded nipple and rotate cover clockwise to tighten securely. (Figure 14). 6. Repeat fan motor cover instructions for second fan CEILING motor assembly. CANOPY DECORATIVE STRAP RING UPPER DECORATIVE DOWNROD SLEEVE SETSCREW (4) DOWNROD FAN ASSEMBLY STRAP SLOT Figure 15 4. Attach the decorative straps to the upper ring using the flat head screw and nut (provided in the FAN MOTOR ASSEMBLY downrod kit), Figure 16. THREADED NIPPLE FAN
Streszczenie treści zawartej na stronie nr. 11
Control Operation: 120 VAC SUPPLY (User Supplied) BUCKLE BLK HOT BLK DECORATIVE STRAP FAN ASSEMBLY STRAP SLOT Figure 18 Figure 17 4. Position the faceplate (not provided) onto the 10. This completes the installation of your ceiling fan. speed control. Using the two 6-32 screws supplied with the faceplate, screw the faceplate and speed control to the wall outlet box (Figure 19). 5. Press knob onto the shaft and rotate counter- How to Wire Your Ceiling clockwise to the full-OFF position. Fan
Streszczenie treści zawartej na stronie nr. 12
AIR DIRECTION SWITCH Reversing Air Flow Direction: (1 switch located on each fan housing) 7 If airflow is desired in the opposite direction, turn the fans off at wall control and wait for the blades to stop turning. Then slide the reversing switches, located on both housings, to the opposite position (Figure 21) and turn the fan on again. The blades will turn in the opposite direction and reverse the airflow. FAN HOUSING Figure 21 Accessories Maintenance IMPORTANT CARE INSTRUCTIONS 1. Ceiling
Streszczenie treści zawartej na stronie nr. 13
! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch wire switch wire connections in the switch housing. connections in the switch housing. ! WARNING: Make sure main
Streszczenie treści zawartej na stronie nr. 14
Repair Parts 1 2 10 19 3 OFF 18 25 4 28 12 20 30 21 13 5 14 15 16 6 17 DOWNROD KIT - SOLD SEPARATELY 27 BLADES - SOLD BLADES - SOLD SEPARATELY SEPARATELY 7 9 8 11 11 26 26 25 25 3 29 23 22 31 32 U.L. Model No.: CF3300 14
Streszczenie treści zawartej na stronie nr. 15
Repair Parts Listing Key Model Numbers No. Description CF3300AP00 CF3300ORH00 1 Hanger Bracket Assembly, 763548 763548 Consisting of: * Structural Mounting Plate — — * Hanger Bracket — — 2 Hanger Ball Assembly, 763550 763550 Consisting of: * Hanger Ball — — 3 Downrod Extension (1) 763553 763553 4 Ceiling Canopy 763552 763552-1 5 Upper Trim Ring 763554 763554-1 6 Upper Decorative Sleeve 763555 763555-1 7 Decorative Downrod Sleeve Assembly 763563 763563-1 8 Blade Flange Set Clockwise (4) 763577 76
Streszczenie treści zawartej na stronie nr. 16
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73850000 Printed in China 02/09 Form No. BP7385 U.L. Model No.: CF3300