Streszczenie treści zawartej na stronie nr. 1
READ AND SAVE THESE INSTRUCTIONS
™
HIGHGROVE
54” Ceiling Fan Owner's Manual
Model Number
CF990BS00
CF990VNB00
Net Weight: 27.5 Lbs.
Part No. F40BP74640000 Form No. BP7464
Model No.: CF990
Streszczenie treści zawartej na stronie nr. 2
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
Streszczenie treści zawartej na stronie nr. 3
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 One 1/4” blade screwdriver One wire stripper MATERIALS ! WARNING Wiring outlet box and box connectors must be of Before assembly your ceiling fan, refer to section type required by the local code. The minimum wire on proper method of wir
Streszczenie treści zawartej na stronie nr. 4
Electrical Requirements Your new ceiling fan will require a grounded electrical ! WARNING supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and Turning off wall switch is not sufficient. To avoid capable of withstanding a load of at least 50 pounds. possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and ! Local codes and the ceiling fan must be properly WARNING
Streszczenie treści zawartej na stronie nr. 5
How to Put Your Ceiling Fan Together (continued) 3. While pulling up on the downrod, securely tighten the two setscrews in the motor coupling (Figure 2). DOWNROD COUPLING COVER NOTE: The setscrews must be properly installed MOTOR as described above, or fan wobble could result. GROMMET HOUSING ! WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fa
Streszczenie treści zawartej na stronie nr. 6
How to Put Your Ceiling Fan Together (continued) 8. Remove and discard the four rubber shipping retainers securing the motor hub in the motor housing assembly (Figure 6). 9. Position one blade medallion onto the blade. RUBBER Place the blade flange to the other side of the SHIPPING blade to secure the medallion and blade to the RETAINERS flange. Mount the medallion, fan blade, and blade MOTOR flange using the three #10-32 x 12.3mm washer HOUSING head blade screws (Figure 7). ASSEMBLY 10. Sli
Streszczenie treści zawartej na stronie nr. 7
How to Put Your Ceiling Fan Together (continued) 11. Remove one #8-32 x 10mm serrated head screw #8-32 x 10mm from the fan motor housing (reserve for later SERRATED HEAD SCREWS (3) use). Loosen the other two screws to assemble LOWER HOUSING the lower housing to the fan motor housing (Figure 9). 12. Position the lower housing onto the fan motor assembly, aligning each of the the three holes. Attach the lower housing to the fan motor assembly using the three #8-32 x 10mm serrated head screws. Rota
Streszczenie treści zawartej na stronie nr. 8
How to Hang Your Ceiling Fan ! WARNING CEILING Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. AT LEAST 7' CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or re
Streszczenie treści zawartej na stronie nr. 9
N I C AC IN L A How to Wire Your Ceiling Fan If you feel that you do not have enough electrical SUPPLY WHITE WIRE wiring knowledge or experience, have your fan (NEUTRAL) RECEIVER WHITE WIRE installed by a licensed electrician. RECEIVER BLACK WIRE SUPPLY BLACK ! RECEIVER WARNING WIRE (HOT) BLACK WIRE GROUND WIRE Turning off wall switch is not sufficient. To avoid RECEIVER possible electrical shock, be sure electricity is BLUE WIRE GREEN GROUND turned off at the main fuse box before wiri
Streszczenie treści zawartej na stronie nr. 10
How to Wire Your Ceiling Fan (continued) 4. Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket. Position the antenna wire on top of the receiver. 5. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket. CEILING COVER 6. Lift the ceiling cover up to the threaded studs and THREADED STUDS (2) turn until studs protrude through the holes in the ceiling cover (Figure 17). LOCKWASHERS (2) 7. Secure the ceiling c
Streszczenie treści zawartej na stronie nr. 11
Remote Control Procedures General Your Emerson Ceiling Fan/Light Remote Control REMOTE CONTROL LEVERS consists of hand-held transmitter and a receiver which ON is mounted under the fan ceiling cover. The remote 1 234 5 I control is designed to separately control your ceiling fan speed and light intensity. There are four push TWO AAA . .. ... .... BATTERIES buttons ( , , , ) to set the fan speed and turn the fan off. The light ( ) push button turns the light on and off and controls the li
Streszczenie treści zawartej na stronie nr. 12
Using Your Fan IMPORTANT Fan installation must be completed, including the TO INSTALL installation of the fan blades, before testing of the COVER BRACKET TO WALL: SLIDE THE COVER remote control. WALL UP TO EXPOSE THE BRACKET SCREW HOLES FOR Your remote control has full control of your fan and INSTALLATION SCREW HOLES (2) light (Figure 21). 1.To set the desired fan speed, press one of the four POWER INDICATOR . .. ... .... LIGHT buttons ( , , , ) to operate your fan from low to FAN BUTTON
Streszczenie treści zawartej na stronie nr. 13
Trouble Shooting WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. ! TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, 2. Check line wire connections to fan and switch or loose switch wire connections in the wire connections in the switch housing. switch housing. ! WARNING: Make sure mai
Streszczenie treści zawartej na stronie nr. 14
Repair Parts 2 1 7 4 3 12 13 8 23 9 14 6 24 15 5 10 20 11 16 21 22 17 18 19 14 Model No.: CF990
Streszczenie treści zawartej na stronie nr. 15
Repair Parts Listing Key Model Numbers No. Description CF990BS00 CF990VNB00 * Hanger Ball Assembly, 761655-17 761655-89 Consisting of: 1 Hanger Bracket —— 2 Hanger Ball —— 3 Downrod (4.5”) —— * Parts Bag Containing: 764286 764286-1 4 Wire Connector (3) —— 5 Pin, Clevis (1) —— 6 Clip, Hairpin (1) —— 7 Threaded Stud, #8-32 x 1-1/4” (2) —— 8 Lockwasher, External Tooth #8 (2) —— 9 Knurled Knob, #8-32 (2) —— 10 Screw, Washer Head, #10-32 x 12.3mm (16) —— 11 Screw, Round Head Lock Tie Flange, 1/4” x 1
Streszczenie treści zawartej na stronie nr. 16
Emerson Air Comfort Ceiling Fan Limited Warranty What The Limited Warranty Covers: This limited warranty is offered by Air Comfort Products division of Emerson Electric Co. ("Emerson" "we" or "us") located at the address stated below to the original retail purchaser ("you" or "your") of an Emerson Air Comfort Ceiling Fan product ("Emerson Ceiling Fan") and covers the motor and the other components and accessories of the Emerson Ceiling Fan against all defects in workmanship and materials. What T