Streszczenie treści zawartej na stronie nr. 1
READ AND SAVE THESE INSTRUCTIONS
™
AVANT ECO
Ceiling Fan Owner's Manual
Model Numbers
CF921BS00
CF921CK00
CF921GES00
CF921ORB00
54”, 60” or 72” Fan Blades
Net Weight: 18.7 Lbs.
Not Included
Part No. F40BP74330000 Form No. BP7433
ETL Model No.: CF921
Streszczenie treści zawartej na stronie nr. 2
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
Streszczenie treści zawartej na stronie nr. 3
EMERSON QUICK START GUIDE The Quick Start Guide covers the installation ! WARNING instructions common for ceiling fan operations. If additional assistance with wiring, alternate hanging To reduce the risk of fire, electric shock, or personal systems, or lighting options, proceed to the complete injury, mount fan to outlet box marked “Acceptable for Fan instructions of this Owner’s Manual. Support of 22.7 kg. (50 lbs.) or less”, and use screws The Quick Start Guide sections include page numbers s
Streszczenie treści zawartej na stronie nr. 4
EMERSON QUICK START GUIDE Wiring Ceiling Fan (page 10) 1. Connect the green grounding lead from the hanger ball and the BLACK green grounding lead from the hanger bracket to the grounding FAN WIRE GROUND conductor of supply (this may be a bare wire or wire with green WIRE colored insulation). Securely connect wires with wire connectors supplied. WHITE SUPPLY LISTED WIRE (NEUTRAL) CONNECTOR (3) NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wi
Streszczenie treści zawartej na stronie nr. 5
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 One 1/4” blade screwdriver One wire stripper MATERIALS ! WARNING Wiring outlet box and box connectors must be of Before assembly your ceiling fan, refer to section type required by the local code. The minimum wire on proper method of wir
Streszczenie treści zawartej na stronie nr. 6
Electrical Requirements Your new ceiling fan will require a grounded electrical ! WARNING supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and Turning off wall switch is not sufficient. To avoid capable of withstanding a load of at least 50 pounds. possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and ! Local codes and the ceiling fan must be properly WARNING
Streszczenie treści zawartej na stronie nr. 7
How to Put Your Ceiling Fan Together (continued) 3. Make sure the grommet is properly installed in the SETSCREW coupling cover, then slide the coupling cover on the DOWNROD PIN downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that HANGER BALL the ceiling cover and the coupling cover are both oriented correctly (Figure 3). 4. Reinstall the hanger ball (Figure 3) on the downrod CEILING as follows. Route the two 80” motor leads through COVER the hanger
Streszczenie treści zawartej na stronie nr. 8
How to Put Your Ceiling Fan Together (continued) 11. Remove the four switch housing mounting SWITCH screws (Figure 7) from the switch housing plate. HOUSING ASSEMBLY Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the four screws (Figure 7). NOTE: Tuck in both the blue and white wires carefully under the switch housing cover ! WARNING MOUNTING SCREWS (
Streszczenie treści zawartej na stronie nr. 9
How to Hang Your Ceiling Fan CEILING ! WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 8). AT LEAST 7' ! WARNING FLOOR The outlet box and joist must be securely mounted and Figure 8 capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”. NOTE: CEILING COVER OUTLET OMITTED FOR CLARITY. ! BOX WARNING To reduce the risk of fire, electrical shock, or personal injury, mount fan to o
Streszczenie treści zawartej na stronie nr. 10
How to Wire Your Ceiling Fan If you feel that you do not have enough electrical BLACK wiring knowledge or experience, have your fan FAN WIRE GROUND installed by a licensed electrician. WIRE LISTED WIRE WHITE SUPPLY ! WARNING (NEUTRAL) CONNECTOR (3) To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, GREEN WIRE as it must be grounded for safe o
Streszczenie treści zawartej na stronie nr. 11
Installation of Remote Control Battery Your Emerson Ceiling Fan/Light SR600 Remote 1. Remove the battery cover by pressing firmly below Control consists of hand-held transmitter and a the arrow and sliding the cover off the control receiver which is mounted under the fan ceiling cover. (Figure 13). The remote control is designed to separately control 2. Install two AAA alkaline batteries and reinstall the your ceiling fan speed, airflow direction and light battery cover. intensity. The remote c
Streszczenie treści zawartej na stronie nr. 12
Operation of Your Remote Control 5. To vary the intensity of the light, hold the DN or UP ! WARNING button down until the desired light intensity is Fan installation must be completed, including reached, then release the button. the installation of the fan blades, before testing 6. The sixth switch marked ON and I is for dimming the remote control. control of lights: Set switch to ON to allow for dimming of the lights. Set switch to I for no Your SR600 Fan/Light remote control (Figure 18) has di
Streszczenie treści zawartej na stronie nr. 13
Optional Accent Kit Installation CAUTION: To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing light kit assembly. COUPLING COVER COUPLING COVER SCREWS (3) 1. Remove the three coupling cover screws and slide (RETAIN FOR LATER INSTALLATION) the coupling cover up the downrod for installation of light kit assembly (Figure 16). Retain the three screws for later installation of coupling cover. UPPER FAN 2. Position the light kit assembly so th
Streszczenie treści zawartej na stronie nr. 14
Maintenance IMPORTANT CARE INSTRUCTIONS ! WARNING for your Ceiling Fan Do not use water when cleaning your ceiling fan. It Periodic cleaning of your new ceiling fan is the only could damage the motor or the blades and create the maintenance that is needed. possibility of an electrical shock. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to finish. Accessories 1. Ceiling Fan
Streszczenie treści zawartej na stronie nr. 15
Trouble Shooting WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. ! TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, 2. Check line wire connections to fan and switch or loose switch wire connections in the wire connections in the switch housing. switch housing. ! WARNING: Make sure mai
Streszczenie treści zawartej na stronie nr. 16
Repair Parts 2 1 3 7 14 15 4 13 8 16 9 5 20 6 19 10 BLADES SOLD SEPARATELY 17 12 18 11 16 ETL Model No.: CF921
Streszczenie treści zawartej na stronie nr. 17
Repair Parts Listing Key Model Numbers No. Description CF921BS00 CF921CK00 CF921GES00 CF921ORB00 * Hanger Ball Assembly, 761655-17 761655-23 761655-35 761655-32 Consisting of: 1 Hanger Bracket — — — — 2 Hanger Ball — — — — 3 Downrod (4.5”) — — — — * Parts Bag Containing: 764124-1 764124-1 764124 764124 4 Wire Connector (3) — — — — 5 Pin, Clevis (1) — — — — 6 Clip, Hairpin (1) — — — — 7 Threaded Stud, #8-32 x 1-1/4” (2) — — — — 8 Lockwasher, External Tooth #8 (2) — — — — 9 Knurled Knob, #8-32 (2)
Streszczenie treści zawartej na stronie nr. 18
Notes 18 ETL Model No.: CF921
Streszczenie treści zawartej na stronie nr. 19
Notes ETL Model No.: CF921 19
Streszczenie treści zawartej na stronie nr. 20
LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your