INSTALLATION
RM2351 RM2554 RM2852
MANUAL
RM2354 RM2652 RM2862
RM2451 RM2662 RM3862
REFRIGERATOR FOR LP-GAS
RM2454 RM2663 NDR1062
& ELECTRIC OPERATION
RM2551
FOR YOUR SAFETY POUR VOTRE SÉCURITÉ
If you smell gas: Si vous sentez une odeur de gaz:
1. Open windows. 1. Ouvrez les fenêtres.
2. Don’t touch electrical switches. 2. Ne touchez à aucun interrupteur.
3. Extinguish any open fl ame. 3. Éteignez toute fl amme nue.
4. Immediately call your gas supplier. 4. Avertissez immédiatement votre
four
Streszczenie treści zawartej na stronie nr. 2
INTRODUCTION This manual describes the installation procedure of the following refrigerator models: RM2351, RM2354, RM2451, RM2454, RM2551, RM2554, RM2652, RM2662, RM2663, RM2852, RM2862, RM3862 and NDR1062. For information about mainte- nance and operating instructions, refer to the USER MANUAL (825 12 57-00). The unit must be installed by qualifi ed personnel only. This manual should be read and understood before installation. Follow the instructions and comply with installation specifi cati
Streszczenie treści zawartej na stronie nr. 3
CERTIFICATION AND CODE REQUIREMENTS This appliance is certifi ed under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation must conform with local codes, or in absence of local codes, the following standards as applicable. In CANADA, the installation must conform with: In the U.S. the installation must conform with: • Natural Gas and Propane Installation Code, CSA B149.1 • National Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest edition). • CSA Z240 RV Series, Re
Streszczenie treści zawartej na stronie nr. 4
VENTILATION REQUIREMENTS VENTILATION HEIGHTS It is essential that all maximum or minimum dimensions are A The upper vent strictly maintained, as the performance of the refrigerator is de- should be centered pendent on adequate fl ow of air over the rear of the refrigerator. over the condenser coil at the back of the refrigerator. Minimum ventilation heights Minimum ventilation Roof vent and Upper and lower A B height lower side vent side vent Condenser Condenser Condenser Condenser Conde
Streszczenie treści zawartej na stronie nr. 5
VENTILATION REQUIREMENTS OVERALL AND RECESS DIMENSIONS Dimensions Dimensions Overall Recess Model Height A Width B Depth C Height H Width W Depth D 30-5/32 21-7/8 22-22/32 29-3/4 20-1/2 21-3/8 inches RM2351 RM2354 766 556 577 756 521 542 mm 37-3/8 24-7/8 24-11/16 39-9/16 23-11/16 24 inches RM2451 RM2454 948 632 627 928 602 610 mm 43-1/2 24-7/8 24-11/16 42-5/8 23-11/16 24 inches RM2551 RM2554 1104 632 627 1083 602 610 mm 54-21/32 24-7/8 26-1/32 53-3/4 23-11/16 24 i
Streszczenie treści zawartej na stronie nr. 6
INSTALLATION INSTRUCTIONS INSTALLING THE REFRIGERATOR SECURING THE REFRIGERATOR When installing the refrigerator, make sure the heat can not be Be careful when installing the refrigerator model trapped in the space between the refrigerator and storage area. NDR1062. It is equipped with the latest vacuum This would make the top of the refrigerator hot and reduces the insulated panel technology. These insulating panels effi ciency of the refrigerator. Any space between the counter, are locat
Streszczenie treści zawartej na stronie nr. 7
INSTALLATION INSTRUCTIONS b) Secure the refrigerator and the lower front strip DRAIN WATER HOSE with two screws: One screw through the hinge A hole must be drilled through fl ooring and the installer needs and on the opposite side and then, one screw to make sure the hose does not kink when run through the fl oor. through the lower front strip. Seal around the hose that goes through the drilled hole. If a longer hose than supplied is required to get the water to drain outside of the vehic
Streszczenie treści zawartej na stronie nr. 8
INSTALLATION INSTRUCTIONS Testing LP gas safety shut off Electrical connection The gas safety shut off must be tested after the refrigerator is 120 V AC connection connected to LP gas supply. The refrigerator is equipped with a grounded three-prong plug RM2354-2454-2554-2662-2663-2862-3862 &NDR1062 for protection against shock hazards. It should be plugged di- rectly into a properly grounded three-prong receptacle. Do not To test the gas safety shut off, follow these steps: cut or remove the
Streszczenie treści zawartej na stronie nr. 9
INSTALLATION INSTRUCTIONS For 3-way models, the voltage drop affects the wattage output 12 V DC connection of the 12V cartridge heater and the refrigerator performance. RM2451-2551-2652-2852: These refrigerator models are not The 12V DC heater is fused with a 30 amp. in-line blade fuse. designed for 12 V DC operation of the cooling system. How- Recommended wire sizes are displayed in the following table: ever, 12 V DC must be supplied to operate the controls. RM2354-2454-2554-2662-2663-286
Streszczenie treści zawartej na stronie nr. 10
MOUNTING INSTRUCTIONS Snap in RM2351-2354 To mount the panel, follow these steps: We recommend to mount the panel on the door before the refrigerator is installed in the enclosure. 1. Open the door 90 degrees. 1 To mount the panel, follow these steps: 2. On new refrigerators, the decoration strip are 1. Slide the panel from the bottom of the door into the taped inside the door; grooves on the vertical edges of the door . if installed on the door, 2 2. Push the panel upwards. remove th
Streszczenie treści zawartej na stronie nr. 11
APPENDIX A - REARVIEW EQUIPMENT RM2351 Heater Flue baffle Drain water hose Power module cover Protection cover Screw for protection cover Burner jet 12 V DC Manual gas shutoff valve Terminal block Inlet fitting Flexible cord RM2354 Heaters Relay Flue baffle Drain water hose Power module cover Protection cover Screw for protection cover Burner jet 12 V DC Manual gas shutoff valve Terminal block Inlet fitting Flexible cord - 11 -
Streszczenie treści zawartej na stronie nr. 12
APPENDIX A - REARVIEW EQUIPMENT RM2451-2454-2551-2554 Heater Relay, 3-way only Flue baffle Power module cover Protection cover 12V DC Screw for protection cover Burner jet 12 volt Terminal block Manual gas shutoff valve Inlet fitting Flexible cord Drain water hose RM2652-2662-2663-2852-2862-3862-NDR1062 Heater(s) Relay, 3-Way only Thermofuse Flue baffle Power module cover Protection cover 12V DC Screw for protection cover 12 volt DC Terminal block Burner jet Drain water hose Manual gas Flexible
Streszczenie treści zawartej na stronie nr. 13
APPENDIX B - WIRING DIAGRAMS RM2351-2451-2551 RM2354-2454-2554 - 13 -
Streszczenie treści zawartej na stronie nr. 14
APPENDIX B - WIRING DIAGRAMS RM2652-2662-2852-2862 RM2663 - 14 -
Streszczenie treści zawartej na stronie nr. 15
APPENDIX B - WIRING DIAGRAMS RM3862 - NDR1062 (BS, SS)* NDR1062 (B)* * BS = Black stainless steel doors SS = Stainless steel doors B = Door insert panels - 15 -
Streszczenie treści zawartej na stronie nr. 16
TO THE INSTALLER PLEASE AFFIX THESE INSTRUCTIONS TO THE REFRIGERATOR — TO THE CONSUMER PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE