Streszczenie treści zawartej na stronie nr. 1
OWNERS MANUAL FOR
PERMANENTLY LUBRICATED AIR COMPRESSOR
Accuset
MODEL NO.
PC2053-1
*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as
the branch circuit the air compressor is operated on.
D23708 Rev. 0 3/20/01
Streszczenie treści zawartej na stronie nr. 2
TABLE OF CONTENTS Page Page SAFETY GUIDELINES ...........................2 Voltage and Circuit Protection .........8 Extension Cords ...............................8 WARNING CHART ............................ 3-5 Grounding Instructions ..................... 8 Additional Regulators and GLOSSARY ............................................ 6 Controls ............................................ 8 Break-In Procedures ......................... 9 SPECIFICATION CHART ......................6 OPERATING
Streszczenie treści zawartej na stronie nr. 3
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROP- ERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT. SAVE THESE INSTRUCTIONS. OWNER’S MANUAL SHOULD REMAIN WITH UNIT AT ALL TIMES. HAZARD RISK OF EXPLOSION OR FIRE WHAT CAN HAPPEN HOW TO PREVENT IT IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTI- MOTOR AND
Streszczenie treści zawartej na stronie nr. 4
HAZARD RISK FROM FLYING OBJECTS WHAT CAN HAPPEN HOW TO PREVENT IT THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE ALWAYS WEAR ANSI Z87.1 APPROVED SAFETY GLASSES DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT, CHIPS, WITH SIDE SHIELDS WHEN USING THE COMPRESSOR. LOOSE PARTICLES AND SMALL OBJECTS AT HIGH SPEED, NEVER POINT ANY NOZZLE OR SPRAYER TOWARD ANY RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY. PART OF THE BODY OR AT OTHER PEOPLE OR ANIMALS. ALWAYS TURN THE COMPRESSOR OFF AND BLEED PRES- SURE
Streszczenie treści zawartej na stronie nr. 5
HAZARD RISK FROM MOVING PARTS WHAT CAN HAPPEN HOW TO PREVENT IT MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELT NEVER OPERATE THE COMPRESSOR WITH GUARDS OR CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT COVERS WHICH ARE DAMAGED OR REMOVED. WITH YOU OR YOUR CLOTHING. ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED ANY REPAIRS REQUIRED ON THIS PRODUCT SHOULD BE OR MISSING PARTS OR ATTEMPTING TO REPAIR COM- PERFORMED BY AUTHORIZED SERVICE CENTER PERSON- NEL.
Streszczenie treści zawartej na stronie nr. 6
SPECIFICATIONS PC2053-1 Model No. 2 Horsepower 3.6 SCFM @ 40 psig 2.5 SCFM @ 90 psig 100 PSI Cut-In 125 PSI Cut-Out 120/60/1 Voltage-Single Phase 15 AMPS Minimum Branch Circuit Requirement Time Delay *Fuse Type 10 AMPS Amperage at Max. Pressure GLOSSARY SCFM or CFM: Standard Cubic Feet per Minute; a unit which the motor automatically re-starts is called "cut-in of measurement of air delivery. pressure." PSIG or PSI: Pounds per square inch gauge. CUT-OUT PRESSURE: When you turn on your air co
Streszczenie treści zawartej na stronie nr. 7
DESCRIPTION OF OPERATION Air Compressor Pump (Included in compressor as- the air tank pressure reaches the factory set “cut-out” sembly): To compress air, the piston moves up and down pressure. in the cylinder. On the downstroke, air is drawn in through Regulator: The air pressure coming from the air tank is the air intake valves. The exhaust valves remain closed. controlled by the regulator. Turn the regulator knob On the upstroke of the piston, air is compressed. The clockwise to increase
Streszczenie treści zawartej na stronie nr. 8
INSTALLATION AND BREAK-IN PROCEDURES Do not modify the plug that has been provided. If it does Location of the Air Compressor not fit the available outlet, the correct outlet should be Your compressor comes to you completely assembled installed by a qualified electrician. and ready for use. Operate the air compressor in a dry, clean, cool and well ventilated area. The air compressor If repairing or replacing cord or plug, the grounding wire pump and case are designed to allow for proper coolin
Streszczenie treści zawartej na stronie nr. 9
INSTALLATION AND BREAK-IN PROCEDURES b. Plug the power cord into the correct branch Break-in Procedures circuit receptacle. c. Turn the drain valve clockwise, opening it fully, to prevent air pressure build-up in the tank. d. Move the pressure switch lever to "ON/AUTO". Serious damage may result if the fol- The compressor will start. lowing break-in instructions are not e. Run the compressor for 15 minutes. Make sure closely followed. the drain valve is open and there is little tank pressure bui
Streszczenie treści zawartej na stronie nr. 10
TROUBLESHOOTING GUIDE PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES. PERSONAL INJURY MAY OCCUR. PRIOR TO ATTEMPTING ANY REPAIRS, UNPLUG THE COMPRESSOR AND BLEED OFF TANK AIR PRESSURE. PROBLEM CAUSE CORRECTION Excessive tank pressure - safety Pressure switch does not shut off motor Move the pressure switch lever to the “OFF” position. valve pops off. when compressor reaches “cut-out” If the unit doesn’t shut off, and the electrical contacts pressure. are
Streszczenie treści zawartej na stronie nr. 11
TROUBLESHOOTING GUIDE CORRECTION PROBLEM CAUSE Air leak from safety valve. Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Knocking Noise Defective check valve. Remove and clean, or replace. Prolonged excessive use of air. Compressor is not supplying Decrease amount of air usage. enough air to operate accesso- Compressor is not large enough for air Check the accessory air requirement. If it is higher than ries. req
Streszczenie treści zawartej na stronie nr. 12
PARTS DIAGRAM SSF-621 SSP-473 GA-352 CAC-1275 CAC-1254 AC81-B SSP-6021 DAC-4105-2 CAC-4296-1 SS-1286 TIA-4150 SSW-7367 SST-5314-1 SSW-7480 SUDL-9-1 SSF-607 SSP-480 SUDL-403-1 AC-0430 12-ENG D23708
Streszczenie treści zawartej na stronie nr. 13
PARTS AVAILABLE FOR THIS UNIT Part Number Description * SSF-607 Screw (4 used) * SST-5314-1 Bumper, Rubber (4 used) * SSF-621 Screw, ¼-14 x .625 DAC-4105-2 Pressure Switch * CAC-1254 Isolator Pump (4 used) SSW-7480 Bushing Strain Relief CAC-1275 Check Valve SSP-473 Nut Sleeve Only Availiable with Pressure Switch DAC-4105-2 SUDL-9-1 Screw, 8-32 x .375/.344 (2 used) SSP-480 Nipple SSW-7367 Bushing, Strain Relief SUDL-403-1 Cord Assembly AC-0430 Drain Valve TIA-4150 Safety Valve SS-1286 Nipple, ¼
Streszczenie treści zawartej na stronie nr. 14
AIR COMPRESSOR DIAGRAM D21919 AC-0815 AC-0470 CAC-1213 SUDL-9-1 D23584 AC-0471 CAC-1213 CAC-1199 + SSF-3147 AC-0206 + CAC-4323 SSF-3156 SSG-8169 SSF-995 CAC-1206-1 CAC-1196 CAC-1212 DAC-269 14-ENG D23708
Streszczenie treści zawartej na stronie nr. 15
PARTS LIST Part Number Description x SSF-995 Screw #10-24 x 7/8 LG. Hex head thd forming (4 used) CAC-1196 Cylinder Head * CAC-1212 Tube Seal * CAC-1199 Gasket Head CAC-4323 Valve Plate Assembly * SSG-8169 O-ring + ————— Rod Assembly x SSF-3147 Screw, 3/8-16 socket head + ————— Cylinder Sleeve D23584 Endbell Assembly AC-0815 Timing Belt * CAC-1213 Pump Isolator (5 used) x SUDL-9-1 Screw, 8-32x .375/.344 AC-0471 Shroud, Left AC-0470 Shroud, Right D21919 Motor Cord DAC-269 Outlet Tube CAC-1206-1 C
Streszczenie treści zawartej na stronie nr. 16
ACCUSET COMPRESSOR AND PARTS WARRANTY This compressor has been designed and constructed using the highest standards of material and workmanship. COMPRESSOR WARRANTY: The length of this guarantee is one year from date of purchase by the original retail purchaser. During this period, Senco Products, Inc., will repair or replace at Senco’s option, any original part or parts for the original retail purchaser. This will be done free of charge, provided the parts are determined defective in material
Streszczenie treści zawartej na stronie nr. 17
MANUAL DEL OPERADOR PARA COMPRESOR DE AIRE PERMANTEMENTE LUBRICADO Accuset MODELO NO. PC2053-1
D23708 Rev. 0 3/20/01
Streszczenie treści zawartej na stronie nr. 18
TABLA DE CONTENIDOS
"#! $!
%
&
'#!
Streszczenie treści zawartej na stronie nr. 19
INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES LA OPERACIÓN O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRÍAN OCASIONAR SERIAS LESIONES Y DAÑOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS LAS ADVERTENCIAS E INSTRUCCIONES DE FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. EL MANUAL DEL PROPIETARIO DEBERÍA PERMANECER TODO EL TIEMPO JUNTO A LA UNIDAD. PELIGRO RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? PARA LOS CONTACTOS ELÉCTRICOS ES NORMAL LA EXISTENCI
Streszczenie treści zawartej na stronie nr. 20
PELIGRO RIESGO DE OBJETOS ARROJADOS POR EL AIRE. ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? EL CHORRO DE AIRE COMPRIMIDO PUEDE CAUSAR DAÑOS SOBRE LOS AL UTILIZAR EL COMPRESOR, USE SIEMPRE ANTEOJOS DE SEGURIDAD TEJIDOS BLANDOS DE LA PIEL EXPUESTA, Y PUEDE PROPULSAR SUCIEDAD, Z87.1 APROBADOS, CON PROTECCIÓN LATERAL. ASTILLAS, PARTÍCULAS SUELTAS Y PEQUEÑOS OBJETOS A ALTA VELOCIDAD, OCASIONANDO DAÑOS A LA PROPIEDAD O LESIONES PERSONALES. JAMÁS APUNTE NINGUNA BOQUILLA O PULVERIZADOR HACIA PARTES DEL CUERP