Streszczenie treści zawartej na stronie nr. 1
ML-82 III Installation Manual
Gas – DSI / Steam Models / Phase 7
Fire Suppression System
WARNING: For your safety the information AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
in this manual must be followed to
notice pour réduire au minimum le risque
minimize the risk of fire or explosion and
d’incendie ou d’explosion ou pour éviter
to prevent property damage, personal
tout dommage matériel, toute blessure ou
injury or death.
la mort.
— Do not store or use gasol
Streszczenie treści zawartej na stronie nr. 2
Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer. The following “FOR YOUR SAFETY” caution must be po
Streszczenie treści zawartej na stronie nr. 3
! WARNING Proposition 65 Use of this product could expose you to substances from fuel combustion that contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Adm
Streszczenie treści zawartej na stronie nr. 4
WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer. Dryer must not be installed or stored in an area where it will be exposed to w
Streszczenie treści zawartej na stronie nr. 5
Table of Contents SECTION I SAFETY PRECAUTIONS .............................................................................................................................. 2 SECTION II SPECIFICATIONS/COMPONENT IDENTIFICATION ......................................................................... 4 A. Specifications .......................................................................................................................................... 4 B. Component Identification ..........
Streszczenie treści zawartej na stronie nr. 6
SECTION I SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. 1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 2. Purchaser/user shoul
Streszczenie treści zawartej na stronie nr. 7
7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer. The frequency of inspection and cleaning can best be determined from experience at each location. WARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard. 8. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the National Electrical Code ANSI/NFPA
Streszczenie treści zawartej na stronie nr. 8
SECTION II SPECIFICATIONS/COMPONENT IDENTIFICATION A. SPECIFICATIONS TUMBLER DIAMETER 37” 94 cm TUMBLER DEPTH 36” 91.5 cm TUMBLER VOLUME 22.4 cu ft 634.29 L 0.373 kW TUMBLER/DRIVE MOTOR 1/2 hp 2.2 kW BLOWER/FAN MOTOR 3 hp 79.7 cm DOOR OPENING (DIAMETER) 31-3/8” 63.5 cm DOOR SILL HEIGHT 25” WATER CONNECTION 3/4”-11.5 NH (North America) 3/4” B.S.P.T. (Outside North America) DRYERS PER 20’/40’ CONTAINER 10 / 20 DRYERS PER 48’/53’ TRUCK 24 / 26 VOLTAGE AVAILABLE 208-460V 3ø 3,4w 50/60 Hz
Streszczenie treści zawartej na stronie nr. 9
Specifications NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. 113344-9 www.amdry.com 5
Streszczenie treści zawartej na stronie nr. 10
B. COMPONENT IDENTIFICATION 1. Dryer Front View Illus. No. Description 1 Controls 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Compartment Area (lint screen located behind door) 5 Lint Drawer 6 Data Label and Installation Label 6 American Dryer Corp. 113344-9
Streszczenie treści zawartej na stronie nr. 11
2. Dryer Rear View Illus. No. Description 1 Heating Unit 2 1/8” Compressed Air Supply Inlet (behind electric service relay box for steam units only) 3* Electric Service Relay Box 4 Basket (tumbler) Bearing Mount Assembly 5 Idler Bearing Mount Assembly 6 Blower Motor Assembly 7 Leveling Leg (rear) 8 Basket (tumbler) (drive) Motor Assembly (reversing models only) 9 Dryer Exhaust * Electric service connections for gas models and steam models are made in this box. 113344-9 www.amdry.com 7
Streszczenie treści zawartej na stronie nr. 12
SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Pr
Streszczenie treści zawartej na stronie nr. 13
IMPORTANT: Dryer must be installed in a location/environment, which the ambient temperature remains between 40º F (4.44º C) and 130º F (54.44º C). B. UNPACKING/SETTING UP Remove protective shipping material (i.e., plastic wrap and optional shipping box) from dryer. IMPORTANT: Dryer must be transported and handled in an upright position at ALL times. The dryer can be moved to its final location with or without the skid attached. To unskid the dryer, locate and remove the four (4) bolts securing
Streszczenie treści zawartej na stronie nr. 14
C. DRYER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible material. NOTE: Allowances must be made for opening the control door. A 40-inches (101.6 cm) for optimum opening of load door. B The maximum thickness of the bulkhead is 4-inches (10.16 cm). For electric dryers the maximum thickness of the bulkhead is 1-inch (2.54 cm) within 3-inches (7.62 cm) from the top of the control door. C For gas and electric dryers a minimum overhead clearance of 12-inches (30.48
Streszczenie treści zawartej na stronie nr. 15
D. FRESH AIR SUPPLY REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition problems and sail switch “fluttering” problems may result, as well as premature motor failure from overheating. Air supply (make-up air) mu
Streszczenie treści zawartej na stronie nr. 16
E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shut down of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-heat thermostats. The dryer must be installed with a proper exhaust duct connection to the outside. CAUTION: T
Streszczenie treści zawartej na stronie nr. 17
Outside Ductwork Protection To protect the outside end of the horizontal ductwork from the weather, a 90º elbow bent downward should be installed where the exhaust exits the building. If the ductwork travels vertically up through the roof, it should be protected from the weather by using a 180º turn to point the opening downward. In either case, allow at least twice the diameter of the duct opening and the nearest obstruction. IMPORTANT: DO NOT use screens, louvers, or caps on the outside open
Streszczenie treści zawartej na stronie nr. 18
IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits noted in this manual, a professional heating, ventilating, and air-conditioning (HV AC) firm should be consulted for proper venting information. ALL ductwork should be smooth inside with no projections from sheet metal screws or other obstructions, which will collect lint. When adding ducts, the duct to be added should overlap the duc
Streszczenie treści zawartej na stronie nr. 19
IMPORTANT: No more than four (4) dryers should be connected to one (1) main common duct. The main duct may be any shape so long as the minimum cross-sectional area is provided. The illustration on page 16 shows the minimum cross section area for multiple dryer round or square venting. These figures must be increased 10 square inches (64.52 squares centimeters) when rectangular main ducting is used, and the ratio of duct width to depth should not be greater than 3-1/2 to 1. These figures must
Streszczenie treści zawartej na stronie nr. 20
F. ELECTRICAL INFORMATION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian E