Streszczenie treści zawartej na stronie nr. 1
Heated Air Curtains
INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL
MODELS: E3606-1125HFD, E3609-1125HFD, E3612-1125HFD
E3806-1125HFD, E3809-1125HFD, E3812-1125HFD
E4206-1125HFD, E4209-1125HFD, E4212-1125HFD
E4806-1125HFD, E4809-1125HFD, E4812-1125HFD
E6006-2125HFD, E6009-2125HFD, E6012-2125HFD
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE
PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH INSTRUCTION
Streszczenie treści zawartej na stronie nr. 2
Unpacking 5. Carefully disconnect motor electric cord and heater 1. With packaged unit on the floor, carton arrows should plug assembly and remove two wing nuts on blower point upward. base. (See Figure 4.) 2. Carefully remove staples from top of carton and fold STYROFOAM back sides. SUPPORT 3. Carefully remove cabinet from carton by lifting out BLOCK unit using finger holes in styrofoam side inset and place on work surface. CAUTION: Do not attempt to lift this air curtain by its louver or dam
Streszczenie treści zawartej na stronie nr. 3
Installation 1. Using template provided, determine mounting 4. Run proper size copper power supply conductors from location. the field power supply disconnects, (supplied by others) with insulation rated minimum 75˚C (167.0˚F). 2.Drill holes and attach mounting hardware (not One set of conductors from 240VAC, 50/60Hz supply included). source shall be routed through the 3/4 inch conduit IMPORTANT: THE HARDWARE AND THE knockout, using a suitable knockout connected to the SUPPORTING STRUCTURE MUST
Streszczenie treści zawartej na stronie nr. 4
Operation 1.After power has been connected to unit, fans will startNOTE: Air direction settings shown in Figures 6 & 7. in either preset (high/low) speed selection. NOTE: Cold air will try to escape near floor level. 2.Air velocity is controlled by selection of high or lowWarm air will try to penetrate curtain near top of speed indicator. This feature allows the setting of air doorway. Air flow can be controlled by direction of velocity to individual desired performance and energy nozzle louvers
Streszczenie treści zawartej na stronie nr. 5
Troubleshooting Chart SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Fan inoperative 1. Blown fuse or open circuit breaker. 1. Replace fuse or reset circuit breaker. 2. Electricity turned off. 2. Contact local power company. 3. Loose cord connection. 3. Re-check all connections. 4. Defective capacitor or motor. 4. Replace. Excessive noise 1. Wheel rubbing on housing. 1. Center wheel. 2. Motor base or blower not securely 2. Tighten mounting bolts. anchored. 3. Replace motor. 3. Defective motor beari
Streszczenie treści zawartej na stronie nr. 6
1. Replacement Parts For Air Curtain Cabinets 3 6 5 4 2 14 Replacement Parts 12 For Motor Blower Assemblies (7) 11 16 13 15 8 10 9 9 2 6 3 8 4 5 Replacement Parts 7 For Heater Units 1C 1D 1A 1B Figure 8 - Replacement Parts. 6
Streszczenie treści zawartej na stronie nr. 7
Replacement Parts List For Air Curtain Cabinets Key Part Numbers for Cabinets (length) No. Description 36" 38" 42" 48" 60" 1 Cabinet box assembly ACCA36A ACCA38A ACCA42A ACCA48A ACCA60A 2 Cabinet Intake Grille API3685 API3885 API4285 API4885 API6085 3 Cabinet Intake grill knurled nut AP0002 AP0002 AP0002 AP0002 AP0002 4 Cabinet louver kit ACL36 ACL38 ACL42 ACL48 ACL60 5 Electric box ACEB ACEB ACEB ACEB ACEB 6 Electric box cover ACFPSPC ACFPSPC ACFPSPC ACFPSPC ACFPSPC Replacement Parts For 120 Vo
Streszczenie treści zawartej na stronie nr. 8
LIMITED WARRANTY All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for eighteen months from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied
Streszczenie treści zawartej na stronie nr. 9
Heated Air Curtains INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL MODELS: E3606-1325HFD, E3609-1325HFD E3806-1325HFD, E3809-1325HFD E4206-1325HFD, E4209-1325HFD E4806-1325HFD, E4809-1325HFD E6006-2325HFD, E6009-2325HFD READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTION
Streszczenie treści zawartej na stronie nr. 10
Unpacking 5. Carefully disconnect motor electric cord and heater 1. With packaged unit on the floor, carton arrows should plug assembly and remove two wing nuts on blower point upward. base. (See Figure 4.) 2. Carefully remove staples from top of carton and fold STYROFOAM back sides. SUPPORT 3. Carefully remove cabinet from carton by lifting out BLOCK unit using finger holes in styrofoam side inset and place on work surface. CAUTION: Do not attempt to lift this air curtain by its louver or dam
Streszczenie treści zawartej na stronie nr. 11
Installation 1. Using template provided, determine mounting loca- 3. Run proper size copper power supply conductors from tion. the field power supply disconnects, (supplied by 2. Drill holes and attach mounting hardware (not includ- others) with insulation rated minimum 75°C (167.0°F). ed). One set of conductors from 208VAC, 50/60Hz supply source shall be routed through the 3/4 inch conduit IMPORTANT: THE HARDWARE AND THE SUPPORT- knockout, using a suitable knockout connected to the ING STRUCTUR
Streszczenie treści zawartej na stronie nr. 12
Operation 1. After power has been connected to unit, fans will start NOTE: Air direction settings shown in Figures 6 & 7. in either preset (high/low) speed selection. NOTE: Cold air will try to escape near floor level. 2. Air velocity is controlled by selection of high or low Warm air will try to penetrate curtain near top of speed indicator. This feature allows the setting of air doorway. Air flow can be controlled by direction of velocity to individual desired performance and energy nozzle lou
Streszczenie treści zawartej na stronie nr. 13
Troubleshooting Chart SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Fan inoperative 1. Blown fuse or open circuit breaker. 1. Replace fuse or reset circuit breaker. 2. Electricity turned off. 2. Contact local power company. 3. Loose cord connection. 3. Re-check all connections. 4. Defective capacitor or motor. 4. Replace. Excessive noise 1. Wheel rubbing on housing. 1. Center wheel. 2. Motor base or blower not securely 2. Tighten mounting bolts. anchored. 3. Replace motor. 3. Defective motor beari
Streszczenie treści zawartej na stronie nr. 14
1. Replacement Parts For Air Curtain Cabinets 3 6 5 4 2 14 Replacement Parts 12 For Motor Blower Assemblies (7) 11 16 13 15 8 10 9 9 2 6 3 8 4 5 Replacement Parts 7 For Heater Units 1C 1D 1A 1B Figure 8 - Replacement Parts. 6
Streszczenie treści zawartej na stronie nr. 15
Replacement Parts List For Air Curtain Cabinets Key Part Numbers for Cabinets (length) No. Description 36" 38" 42" 48" 60" 1 Cabinet box assembly ACCA36A ACCA38A ACCA42A ACCA48A ACCA60A 2 Cabinet Intake Grille API3685 API3885 API4285 API4885 API6085 3 Cabinet Intake grill knurled nut AP0002 AP0002 AP0002 AP0002 AP0002 4 Cabinet louver kit ACL36 ACL38 ACL42 ACL48 ACL60 5 Electric box ACEB ACEB ACEB ACEB ACEB 6 Electric box cover ACFPSPC ACFPSPC ACFPSPC ACFPSPC ACFPSPC Replacement Parts For 120 Vo
Streszczenie treści zawartej na stronie nr. 16
LIMITED WARRANTY All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for eighteen months from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied
Streszczenie treści zawartej na stronie nr. 17
Heated Air Curtains INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL MODELS: E3606-1425HFD, E3609-1425HFD E3806-1425HFD, E3809-1425HFD E4206-1425HFD, E4209-1425HFD E4806-1425HFD, E4809-1425HFD E6006-2425HFD, E6009-2425HFD READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTION
Streszczenie treści zawartej na stronie nr. 18
Unpacking 5. Carefully disconnect motor electric cord and heater 1. With packaged unit on the floor, carton arrows should plug assembly and remove two wing nuts on blower point upward. base. (See Figure 4.) 2. Carefully remove staples from top of carton and fold STYROFOAM back sides. SUPPORT 3. Carefully remove cabinet from carton by lifting out BLOCK unit using finger holes in styrofoam side inset and place on work surface. CAUTION: Do not attempt to lift this air curtain by its louver or dam
Streszczenie treści zawartej na stronie nr. 19
Installation 1. Using template provided, determine mounting loca- 3. Run proper size copper power supply conductors from tion. the field power supply disconnects, (supplied by 2. Drill holes and attach mounting hardware (not includ- others) with insulation rated minimum 75°C (167.0°F). ed). One set of conductors from 240VAC, 50/60Hz supply source shall be routed through the 3/4 inch conduit IMPORTANT: THE HARDWARE AND THE SUPPORT- knockout, using a suitable knockout connected to the ING STRUCTUR
Streszczenie treści zawartej na stronie nr. 20
Operation 1. After power has been connected to unit, fans will start NOTE: Air direction settings shown in Figures 6 & 7. in either preset (high/low) speed selection. NOTE: Cold air will try to escape near floor level. 2. Air velocity is controlled by selection of high or low Warm air will try to penetrate curtain near top of speed indicator. This feature allows the setting of air doorway. Air flow can be controlled by direction of velocity to individual desired performance and energy nozzle lou