Streszczenie treści zawartej na stronie nr. 1
www.GEAppliances.com
Safety Information . . . . . . . . 2, 3
Owner’s Manual and
Installation Instructions
Operating/Care and
Cleaning Instructions
JN327–Recirculation only
Charcoal Filter . . . . . . . . . . . . . . .5
JV338*–Vent options only
Grease Filter . . . . . . . . . . . . . . . .4
JV347*–Vent & Recirculation
Hood Light . . . . . . . . . . . . . . . . .5
options
Hood Surfaces . . . . . . . . . . . . . . .5
Controls . . . . . . . . . . . . . . . . . . . .4 JV367*–Vent & Recirculation
opt
Streszczenie treści zawartej na stronie nr. 2
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY PRECAUTIONS WARNING – TO REDUCE THE RISK OF FIRE, WARNING – TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE A RANGE TOP GREASE FIRE: THE FOLLOWING: A. Never leave surface units unattended at high A. Use this unit only in the manner intended settings. Boilovers cause smoking and greasy by the manufacturer. If you have questions, spillovers that may ignite. Heat oils slowly on low contact the manufacturer.
Streszczenie treści zawartej na stronie nr. 3
Safety Instructions Operating Instructions Installation Instructions Consumer Support INSTRUCTIONS DE SÉCURITÉ IMPORTANTES. LISEZ TOUTES LES INSTRUCTIONS AVANT D’UTILISER. PRÉCAUTIONS EN MATIÈRE DE SÉCURITÉ AVERTISSEMENT – POUR RÉDUIRE LE AVERTISSEMENT – RÉDUISEZ LE RISQUE D’INCENDIE, DE SECOUSSE ÉLECTRIQUE OU DE RISQUE D’UN FEU DE GRAISSE SUR LA SURFACE DE BLESSURE CORPORELLE, OBSERVEZ LES PRÉCAUTIONS CUISSON DU FOUR : SUIVANTES : A. Ne laissez jamais sans surveillance les unités de A. N’utilis
Streszczenie treści zawartej na stronie nr. 4
Using the hood controls. Throughout this manual, features and appearance may vary from your model. Switch Pad Controls (on some models) Control Knobs (on some models) ON HI OFF OFF OFF ON LO HI OFF LO MED NITE FAN Control LIGHT Control Turn to HI, MED or LO as needed. Press the pad at the top to turn the light ON. Continuous use of the fan system while cooking FAN Control helps keep the kitchen comfortable and less humid. It also reduces cooking odors and soiling Press the pad at the top to tur
Streszczenie treści zawartej na stronie nr. 5
Safety Instructions Operating Instructions Installation Instructions Consumer Support Charcoal Filter–Recirculating Installations Only The charcoal filter cannot be To remove: cleaned. It must be replaced. Order Pull down on the center of the filter no. WB02X10700. Replacement front edge of the filter. The filter filters can be ordered from your GE will then slip out of the retaining supplier. tabs on the back. To replace: Replaceable charcoal filter If the hood is not vented to Slip the back e
Streszczenie treści zawartej na stronie nr. 6
Installation Range Hood Instructions Questions? Visit our Website at: www.geappliances.com or Call GE Answer Center at 800.626.2000 DUCTWORK REQUIREMENTS BEFORE YOU BEGIN NOTE: Read the ductwork sections only if you do not Read these instructions completely and carefully. have existing ductwork. If you have existing ductwork, skip to the “Damage” section and proceed. • IMPORTANT – Save these instructions for local inspector’s use. The venting system must exhaust to the outside. • IMPORTANT – Obs
Streszczenie treści zawartej na stronie nr. 7
Installation Instructions Follow the guidelines for proper duct sizing in the ducting charts. DUCTING CHART: Flow vs. equivalent feet of duct length 300 JV347 250 JV338 200 150 100 50 0 0 20406080100 Equivalent Feet of Duct Length 1 MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of a 3 ⁄4″ x 10″ rectangular, 6″ or 7″ diameter round duct should not exceed 65 equivalent feet. 7 CFM
Streszczenie treści zawartej na stronie nr. 8
Installation Instructions WORKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH DUCT EQUIVALENT NUMBER DUCT EQUIVALENT NUMBER PIECES LENGTH x USED = TOTAL PIECES LENGTH x USED = TOTAL 1 3 ⁄4″ x 10″ 1 Ft. x ( ) = Ft. 6″ Round 34 Ft. x ( ) = Ft. Rect., wall cap (6 ft. w/o straight with damper) x ( ) = Ft. damper 7″ Round, 1 Ft. x ( ) = Ft. straight 6″ Round 30 Ft. x ( ) = Ft. roof cap 6″ Round, 1 Ft. x ( ) = Ft. straight 6″ Round 5.5 Ft. x ( ) = Ft. to 1
Streszczenie treści zawartej na stronie nr. 9
Installation Instructions DAMAGE – SHIPMENT/INSTALLATION TOOLS YOU WILL NEED • If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement. • If the unit is damaged by the customer, repair or Flat blade and Phillips Pencil replacement is the responsibility of the customer. screwdrivers Duct tape • If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and inst
Streszczenie treści zawartej na stronie nr. 10
Installation Instructions 1 CHOOSE VENT OPTION Determine the vent option that your installation will IMPORTANT: If the hood is to be installed in a require and that is available for your model from the recirculating, non-vented ductless manner, do not below choices. knock out any vent openings in the hood. Only an electrical access hole will be knocked out of the hood. Outside top exhaust Outside rear exhaust A C 1 1 (Vertical duct–3 ⁄4″ x 10″ Rectangular) (Horizontal duct–3 ⁄4″ x 10″ Rectangul
Streszczenie treści zawartej na stronie nr. 11
Installation Instructions 5 2 REMOVE EXHAUST ADAPTOR REMOVE WIRING COVER 1 If exhausting/venting using the 3 ⁄4″ x 10″ rectangular Remove the wiring cover from inside the hood. duct—optional for JV338, JV347 and JV367 models Set the cover and its mounting screw aside. only: Remove the exhaust adaptor from the inside of the Wiring hood. Set it aside along with its mounting screws. cover 1 3 ⁄4″ x 10″ rectangular exhaust adaptor and screws 3 REMOVE FILTER Remove the shipping tape holding the me
Streszczenie treści zawartej na stronie nr. 12
Installation Instructions 1 8 7 FOR 3 ⁄4″ X 10″ RECTANGULAR REMOVE DUCT KNOCKOUT If recirculating, non-vented ductless (JN327 and RN328, DUCTED DISCHARGE and optional for JV347 and JV367 models only), skip to INSTALLATIONS ONLY: Step 10 D and proceed. Attach exhaust adaptor/damper over the appropriate Using a flat blade screwdriver, remove the appropriate knockout opening (for vertical or horizontal, duct knockout from the top or back of the hood. depending on installation) with two exhaust ada
Streszczenie treści zawartej na stronie nr. 13
Installation Instructions 10 MARK HOLES C. Outside rear exhaust 1 Select the vent option that your installation will (Horizontal duct–3 ⁄4″ x 10″ Rectangular) require and proceed to that section: • Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, A.Outside top exhaust electrical wiring and keyhole screw slots. 1 (Vertical duct–3 ⁄4″ x 10″ Rectangular) • Use the diagram or the hood as a template and Wood shims (recessed-bottom cabinets only) mark th
Streszczenie treści zawartej na stronie nr. 14
Installation Instructions 14 SCREW IN PARTWAY 11 FOR RECESSED-BOTTOM Drive a mounting screw (from the hardware packet) CABINETS ONLY partway into each center of the narrow neck of the keyhole slots marked on the cabinet bottom. 15 OPTIONAL POWER CORD KIT JXHC1 An optional Power Cord Connection Kit, model Wood shims JXHC1, is available at extra cost from your GE supplier for installation using a standard 3-prong, • If the cabinets have front, side or back trim, make grounded wall outlet. Follow
Streszczenie treści zawartej na stronie nr. 15
Installation Instructions 19 INSTALL LIGHT BULB 17 SECURE HOOD NOTE: A light bulb is not shipped with the hood. Slide the hood back against the wall. Tighten Obtain one locally. Purchase and install an ordinary the mounting screws. Be sure the screw heads screw-base light bulb, not more than 60 watts. are in the narrow neck of the keyhole slot. Mounting screw (4) Keyhole (4) NOTE: DO NOT PUSH ON FAN BLADE. Pushing 20 FOLLOW ELECTRICAL CODE on the blade may cause it to interfere with other Compl
Streszczenie treści zawartej na stronie nr. 16
Installation Instructions 21 CONNECT WIRING 23 REPLACE FILTER Connect house black to hood black wire, house Make sure fan blade turns freely and replace the white to hood white wire and house ground under filter. NOTE: On model JV347, install the metal green ground screw. Securely tighten the strain grease filter if ducted or the charcoal filter if relief clamp onto the house wiring. recirculated. Green ground screw Metal grease filter or charcoal filter WARNING: IMPROPER CONNECTION OF ALUMINUM
Streszczenie treści zawartej na stronie nr. 17
Safety Instructions Operating Instructions Installation Instructions Consumer Support Notes. 17
Streszczenie treści zawartej na stronie nr. 18
Notes. 18 Consumer Support Installation Instructions Operating Instructions Safety Instructions
Streszczenie treści zawartej na stronie nr. 19
Safety Instructions Operating Instructions Installation Instructions Consumer Support GE Range Hood Warranty. All warranty service provided by our Factory Service Centers, or Staple your receipt here. ® an authorized Customer Care technician. To schedule service, Proof of the original purchase on-line, 24 hours a day, visit us at www.GEAppliances.com, or date is needed to obtain service call 800.GE.CARES (800.432.2737). under the warranty. For The Period Of: GE Will Replace: One Year Any part
Streszczenie treści zawartej na stronie nr. 20
Consumer Support. GE Appliances Website www.GEAppliances.com Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, ™ order parts, catalogs, or even schedule service on-line. You can also “Ask Our Team of Experts ” your questions, and so much more... Schedule Service www.GEAppliances.com Expert GE repair service is only one step away from your d