Streszczenie treści zawartej na stronie nr. 1
P RO V ENTILATION H OOD L INERS
INSTALLATION INSTRUCTIONS
Streszczenie treści zawartej na stronie nr. 2
CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equip- ment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if pr
Streszczenie treści zawartej na stronie nr. 3
WOLF PRO VENTILATION HOOD LINERS INSTALLATION REQUIREMENTS IMPORTANT NOTE: This installation must be completed by a qualified installer or Wolf WARNING – TO REDUCE THE authorized service center technician. RISK OF FIRE, ELECTRIC SHOCK, Installer: Please read the entire Installation OR INJURY TO PERSONS, Instructions prior to installation. Save these RATING PLATE OBSERVE THE FOLLOWING: instructions for the local inspector’s refer- INFORMATION ence, then leave them with the homeowner. Homeowner: P
Streszczenie treści zawartej na stronie nr. 4
WOLF PRO VENTILATION HOOD LINERS INSTALLATION REQUIREMENTS INSTALLATION CONSIDERATIONS LIST OF MATERIALS IMPORTANT NOTE: Wolf Pro ventilation hood liners are recommended for use with all Wolf The following is a list of materials shipped cooking appliances and are available to accom- with the Wolf Pro ventilation hood liner. modate 36" (914), 42" (1067), 48" (1219), 54" (1372) and 60" (1524) wide hoods. ACCESSORIES Stainless steel hood liner Proper installation is the responsibility of the instal
Streszczenie treści zawartej na stronie nr. 5
INSTALLATION INSTRUCTIONS OVERALL DIMENSIONS PRO HOOD LINERS TOP WIDTH SUBTRACT 6" (152) FROM OVERALL WIDTH 3 3 Overall Widths 34 /8" (873), 40 /8" (1026), 3 1 /8" (35) 3 3" 22 /4" 3" 12" 3 3 46 /8" (1178), 52 /8" (1330) (76) (578) (76) (305) 3 and 58 /8" (1483) 12" (305) Overall Height 12" (305) OVERALL HEIGHT 4" (102) 1 Overall Depth 22 /2" (572) 1 OVERALL WIDTH 22 /2" (572) Shipping Weight (shell only) 44–65 lbs OVERALL DEPTH (20–29 kg) + 1 Pro Hood Liners Dimensions may vary to /8" (3).
Streszczenie treści zawartej na stronie nr. 6
WOLF PRO VENTILATION HOOD LINERS INSTALLATION SPECIFICATIONS DECORATIVE HOODS The illustration and chart below provide A decorative hood can be created out of wood, dimensions critical for proper installation of plaster, tile or metal. The shape of the decora- the Pro hood liner. tive hood is not critical. The only place where the hood liner and outside cover must meet is at the bottom edge of the liner. The decorative B hood and liner must fit at the bottom edge in HEIGHT OF TRANSITION both wi
Streszczenie treści zawartej na stronie nr. 7
INSTALLATION INSTRUCTIONS INSTALL DUCTWORK To reduce the risk of fire, use only metal DUCTWORK INSTALLATION ductwork. THROUGH ROOF ROOF CAP OR REMOTE BLOWER IMPORTANT NOTE: Wolf recommends that the Pro ventilation hood liner be installed 10" ROUND DUCT 30" (762) to 36" (914) above the countertop. TRANSITION 1 IMPORTANT NOTE: Consult a qualified HVAC 22 /4"W x 9"D SOFFIT OR CABINET TO 10" ROUND 10"H Engineer for specific ducting applications. OR DUCT COVER DIMENSIONS INCLUDE FLANGES DECORATIV
Streszczenie treści zawartej na stronie nr. 8
WOLF PRO VENTILATION HOOD LINERS WALL PREPARATION HOOD LINER PREPARATION If you are installing LBLOWER-120INT, refer to the internal blower information on page Framing must be tied together and to 11 and follow installation instructions ceiling joists to provide enough structural provided with the blower. strength to support the weight of the hood liner and internal blower, if applicable. The hood liner assembly is shipped with the transition attached. The transition is shipped upside down in th
Streszczenie treści zawartej na stronie nr. 9
INSTALLATION INSTRUCTIONS HOOD LINER PREPARATION INSTALL THE HOOD LINER If you are installing an in-line or remote IMPORTANT NOTE: If a backsplash is to be 7 blower, drill a /8" (22) hole through the used, it should be installed before the hood wood framing for the conduit. Refer to the liner is mounted. in-line and remote blower information on Position the hood liner in the desired location pages 12–13 and follow installation instruc- on the wall. Install the #10 x 2" (59) screws tions provide
Streszczenie treści zawartej na stronie nr. 10
WOLF PRO VENTILATION HOOD LINERS INSTALL WIRING Run a 120 V AC, 15 amp circuit (minimum) power cable from the service panel to the This ventilation hood liner must be electrical box in the back of the hood liner. properly grounded and should be installed by a qualified electrician in accordance Insert the conduit through the holes in the with all applicable national and local back of the hood liner to the electrical box. IMPORTANT electrical codes. NOTE Remove the electrical box cover from the
Streszczenie treści zawartej na stronie nr. 11
INSTALLATION INSTRUCTIONS INTERNAL BLOWER IMPORTANT NOTE: Refer to the installation IMPORTANT NOTE: Before turning the power instructions provided with the internal on to the ventilation hood liner, make sure the blower for additional mounting and wiring blower is off. instructions. IMPORTANT NOTE: Use wire connectors or wire nuts approved by UL or C/UL. LBLOWER-120INT INSTALLATION Slide the blower mounting tab into the hood liner top plate mounting slot. Make sure the blower tab and mounting sl
Streszczenie treści zawartej na stronie nr. 12
WOLF PRO VENTILATION HOOD LINERS IN-LINE AND REMOTE BLOWERS BLOWER INSTALLATION Refer to the illustrations below and on the following page for overall dimensions of Wolf IMPORTANT NOTE: Refer to the specific in-line and remote blowers. Also refer to the installation instructions provided with each specific installation instructions provided with blower for additional mounting instructions. each remote blower to verify cut-out dimen- ACCESSORIES Locate the blower so that the length of the sions.
Streszczenie treści zawartej na stronie nr. 13
INSTALLATION INSTRUCTIONS IN-LINE AND REMOTE BLOWERS BLOWER WIRING Plug the cord assembly into the receptacle located near the center of the hood shell. IMPORTANT NOTE: Refer to the specific Use the clips on the interior of the hood to installation instructions provided with each keep excess power cord away from moving blower for additional wiring instructions. parts. Follow wiring instructions at the blower as Reinstall the electrical box cover and outlined in the specific installation instruc-
Streszczenie treści zawartej na stronie nr. 14
WOLF PRO VENTILATION HOOD LINERS INSTALL FILTERS BLOWER ASSEMBLIES Remove all packaging material from the Wolf Pro ventilation hood liners are shipped filters. without the blower assembly. Wolf internal, in-line and remote blower assemblies are Install the filters. Orient each filter with available as sales accessories through your lines running vertically. Position the top Wolf dealer. edge of the filter as shown in the illustra- ACCESSORIES tion below. While pressing up against the IMPORTANT N
Streszczenie treści zawartej na stronie nr. 15
INSTALLATION INSTRUCTIONS TROUBLESHOOTING IF YOU NEED SERVICE IMPORTANT NOTE: If the Pro ventilation hood Maintain the quality built into your Pro liner does not operate properly, follow these ventilation hood liner by calling a Wolf troubleshooting steps: authorized service center. Verify that power is being supplied to the For the name and number of the Wolf ventilation hood liner. authorized service center nearest you, CONTACT check the Locator section of our website, Check electrical connec
Streszczenie treści zawartej na stronie nr. 16
WOLF APPLIANCE COMPANY, INC. P. O. BOX 44848 MADISON, WI 53744 800-332-9513 WOLFAPPLIANCE.COM 810481 2/2007