Streszczenie treści zawartej na stronie nr. 1
OPERATING INSTRUCTIONS
DOUBLE CASSETTE DECK D-480
COUNTER
RESET A/B MODE
BC
HIGH NORM M RELAY P
TAPE SIZE MEMORY NR B/C/OFF
CD SYN MPX MIN SEC
REC REC
RELAY PLAY REVERSE
L
dB R -00 -20 -10 -6 -3 0 +3 +6
EJECT DUBBING / CD SYN REC EJECT
AUTO REVERSE AUTO REVERSE
NORMAL HIGH
HX-PRO
AMS AMS
PLAY/AUTO TAPE SELECTORBA RECORD & PLAY/AUTO TAPE SELECTOR
POWER PHONES REC LEVEL REC BALANCE
ON/OFF
0 10 LR
D-480
Double Cassette Deck
Streszczenie treści zawartej na stronie nr. 2
ENGLISH Unpacking and installation Congratulations on your purchase! Your new high fidelity Integrated Cassette Deck is designed to deliver maximum enjoyment and years of trouble free service. Please take a few moments to read this manual thoroughly. It will explain the features and operation of your Unit and help a trouble free installation. Please unpack your Cassette Deck carefully. We recommend that you save the carton and packing material. They will be helpful if you ever need to move you
Streszczenie treści zawartej na stronie nr. 3
Read this Before Operating Your Unit FOR THE U.S.A. AND CANADA ........................ 120 V FOR AUSTRALIA AND EUROPE ... 220 V/230 V/240 V FOR YOUR SAFETY FOR YOUR SAFETY Units shipped to the U.S.A. and Canada are designed for Units shipped to Australia are designed for operation on operation on 120 V AC only. 240 V AC only. To ensure safe operation the three-pin plug supplied Safety precaution for a polarized AC plug. must be inserted only into a standard three-pin power However, some product
Streszczenie treści zawartej na stronie nr. 4
ENGLISH AUDIO/VIDEO RECEIVER R-325 Rear Panel Connections Do not plug the AC input cord into the AC outlet when making connections. Be sure to connect the white plugs to the L(Left) and the red plugs to the R(Right) jacks when making connections. 4 AC INPUT ~120V / 60Hz MODEL NO. D-480 DOUBLE CASSETTE DECK AC OUTLET LINE DIGI LINK L 5 R REC PLAY UNSWITCHED IN OUT ~120V/60Hz 1A MAX 100W 3 2 DIGI LINK 1 MASTER VOLUME 50 INPUT SELECTOR 45 55 40 60 35 65 STANDBY BAND 30 70 ST TUNED AUTO V
Streszczenie treści zawartej na stronie nr. 5
Front Panel Controls Front Panel Controls 23 24 25 24 23 DOUBLE CASSETTE DECK D-480 COUNTER RESET A/B MODE BC HIGH NORM M RELAY P TAPE SIZE MEMORY NR B/C/OFF CD SYN MPX MIN SEC REC REC RELAY PLAY REVERSE L dB - -20 -10 -6 -3 0 +3 +6 R DUBBING / CD SYN REC EJECT EJECT AUTO REVERSE AUTO REVERSE NORMAL HIGH HX-PRO AMS AMS PLAY/AUTO TAPE SELECTOR RECORD & PLAY/AUTO TAPE SELECTOR BA POWER PHONES REC LEVEL REC BALANCE ON/OFF 0 10 LR 1 2 12 13 23 14 15 9 8 11 17 20 21 18 22 19 10 16 DOUB
Streszczenie treści zawartej na stronie nr. 6
ENGLISH POWER SWITCH Press this switch to turn the power on and press again to turn the power off. For system operation, plug the AC input cord into the switched AC outlet on amplifier or receiver, keep the POWER switch ON and control power ON/OFF with the main POWER switch on the amplifier or receiver. HEADPHONE JACK Stereo headphones with a standard 1/4 inch plug can be plugged into this jack for private listening. REWIND and FAST FORWARD BUTTONS( and ) Press the button to rewind or a
Streszczenie treści zawartej na stronie nr. 7
MEMORY BUTTON Press this button to memorize the specific point on the tape. NR B/C/OFF BUTTON Press this button to select the Dolby B type or C type NR system when playing back or recording. COUNTER RESET BUTTON Press this button to reset the counter to “0000” or “00 min. 00 sec.”. DECK A/B COUNTER SELECTOR BUTTON Press this button to select which deck to be counted. The tape detection indicator blinks 4 times. COUNTER MODE BUTTON Press this button to select the tape or time counter mode.
Streszczenie treści zawartej na stronie nr. 8
ENGLISH Operations PLAYING BACK TAPES POWER ON/OFF Press the POWER switch to turn the power on. 1 Insert the cassette with exposed tape side facing down. To close the cassette door, push the door until it locks shut. 2 EJECT According to the type of the tape loaded, you will see the following display(Auto Tape Selector). BC HIGH NORM Normal tape : NOR is displayed. M RELAY P CD SYN MPX MIN SEC Chrome tape : “CR” is displayed. REC REC Metal tape : “ME” is displayed. L dB -00 -20 -10 -6 -3 0
Streszczenie treści zawartej na stronie nr. 9
Select your desired reverse mode. 4 REVERSE Each time REVERSE MODE button is pressed, mode changes as follows; : One side play or recording. (Side A STOP, Side B STOP) : Side A Side B STOP Side B Side A STOP : Continuous Auto Reverse Mode (Side A Side B Side A ...) To use relay play, load the cassette tapes into DECK A and B and press the RELAY PLAY button. RELAY PLAY The relay patterns are different according to the reverse mode. Refer to the followings. Example : When starting the f
Streszczenie treści zawartej na stronie nr. 10
ENGLISH MUSIC SEARCH PROGRAMMING The automatic music search function automatically skips other programs, finds and starts playback from the desired program. Up to 20th program before or after the present program can be searched quickly. During playback, press the button the desired number of times. Example : When listening to the second program before or after the present program. BC HIGH NORM M RELAY P AMS CD SYN MPX MIN SEC REC REC L dB -00 -20 -10 -6 -3 0 +3 +6 R The second program can be s
Streszczenie treści zawartej na stronie nr. 11
When recording with DOLBY NR system, Select the program source to be recorded. select the desired DOLBY NR system. 3 4 NR B/C/OFF Press the RECORD/RECORD MUTING Adjust the recording level with the REC button to enter the recording pause mode. LEVEL control. (see page 10) 5 6 / REC LEVEL 0 10 : Recordable on both sides : Recordable on front side : Recordable on back side Adjust the balance of the right and left Press the PLAY button to start recording. recording level with the REC BALANCE 7 8
Streszczenie treści zawartej na stronie nr. 12
ENGLISH RECORDING LEVEL ADJUSTMENT The most important factor for good recording result is the recording level adjustment. If the recording level is set at maximum, the signal-to-noise ratio (S/N) and the dynamic range (range of sound volume) will improve, but if it is set too high, the sound quality will deteriorate. On the contrary when the recording level is set too low in order to avoid distortion, tape hiss noise becomes too evident. Even among tapes of the same type, the tape characteristi
Streszczenie treści zawartej na stronie nr. 13
RECORDING A CD AUTOMATICALLY When this unit is connected to a Sherwood DIGI LINK CD player controlled remotely by the DIGI LINK system, the CD Synchro record function can be operated. Before starting CD synchro recording, adjust the recording level and the balance. Repeat steps 1,2,3 and 4 of “RECORDING” According to the tape length, edit the Procedure. tracks to be recorded on the CD player 1 2 referring to the operating instructions of that. Start CD syncro recording. 3 CD SYN REC BC HIGH N
Streszczenie treści zawartej na stronie nr. 14
ENGLISH Press the DUBBING MODE button to To stop dubbing. select the normal or high speed(1.5 times 3 4 normal speed) dubbing. High quality sound will be obtained in the nomal speed dubbing mode. DUBBING NORMAL HIGH Then dubbing will start. NOTE During dubbing, the Dolby NR is automatically set to OFF and the recorded tape can be dubbed as it is. During dubbing, do not change the speed. If so, tape click noise may be recorded. During dubbing, the settings of the REC LEVEL and the REC BALANC
Streszczenie treści zawartej na stronie nr. 15
SELECTING A TAPE LENGTH Select the corresponding tape length according to the loaded tape. TAPE SIZE BC Example : In case of 60 minute tape. HIGH NORM M RELAY P CD SYN MPX MIN SEC REC REC L dB -00 -20 -10 -6 -3 0 +3 +6 R BC HIGH NORM M RELAY P CD SYN MPX MIN SEC REC REC Each time this button is pressed, the tape length changes as follows; L dB -00 -20 -10 -6 -3 0 +3 +6 R C-60 C-90 During playback or recording, the elapsed recording or playback time are displayed. The time counter is not
Streszczenie treści zawartej na stronie nr. 16
ENGLISH DOLBY HX PROFESSIONAL HEAD ROOM EXTENSION(DOLBY HX PRO) 1. Dolby HX PRO is a professional recording bias system which are now available in some home cassette recorders that improving dynamic range and signal clarity for life-like sound quality. When recording audio signals which contain high-frequency components, these components influence the bias and decrease the high recording frequencies. (If the amount of the bias is high, high frequencies are decreased,while the amount of the bias
Streszczenie treści zawartej na stronie nr. 17
Dolby noise reduction and HX Pro headroom extension manufactured under license from Dolby Laboratories Licensing Corporation. HX Pro originated by Bang and Olufsen. ”Dolby”, the double-D symbol, and “HX Pro” are trademarks of Dolby Laboratories Licensing Corporation. NOTES ON CASSETTE TAPE Before loading a cassette tape, take up the slack in the tape to prevent it from becoming entangled around the capstan. After the recording has been finished, remove the tab to prevent the recorded content
Streszczenie treści zawartej na stronie nr. 18
Troubleshooting Guide If your unit does not perform as expected, consult the table below to see if the problem can be corrected before seeking help from your dealer or our service organization. PROBLEM POSSIBLE CAUSE REMEDY No power • The AC input cord is disconnected. • Connect the cord securely. • The POWER switch is not pressed • Press the POWER switch to ON. completely. No sound • Unrecorded tape is loaded. • Load the recorded tape. • Incorrect connections. • Make connections correctly. • In
Streszczenie treści zawartej na stronie nr. 19
Specifications GENERAL Power Requirement.................................................................................................................................................. 120 V, 60 Hz Power Consumption............................................................................................................................................................... 16 W Dimensions(W H D)..................................................................................................
Streszczenie treści zawartej na stronie nr. 20
5707-04683-004-0 (9007018996)