Streszczenie treści zawartej na stronie nr. 1
KOBE Brand Range Hood
Model No.: CH0130SQB (30'')
CH0136SQB (36'')
CH0142SQB (42'')
CH0148SQB (48'')
CH-101 SERIES – 18'' HEIGHT
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
- READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS.........................ERROR! BOOKMARK NOT DEFINED. COMPONENTS OF PACKAGE ................................................................................................. 3 INSTALLATION ......................................................................................................................... 4 UNDER THE CABINET INSTALLATION ...............................................................
Streszczenie treści zawartej na stronie nr. 4
IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) D
Streszczenie treści zawartej na stronie nr. 5
What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. • NEVER PICK UP A BURNING PAN – You May Get Burned. • DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result. • Use an extinguisher ONLY if: a) Yo
Streszczenie treści zawartej na stronie nr. 6
COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) RANGE HOOD BOX KOBE Range Hood – 1 Warranty Registration Card –1 Instructions Manual – 1 Baffle Filter - 2 (30”, 36”, 42”) - 3 (48”) Stainless Steel Spacer - 0 (30”) - 1 (36”) - 2 (42”, 48”) 3/16" X 3/8" (8 pc) Oil Tunnel – 1 Ducting Transition – 1 DUCT COVER KIT (Sold Separately) Screw Package
Streszczenie treści zawartej na stronie nr. 7
INSTALLATION PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to Table 1. (All calculation in inches.) - FOR UNDER THE CABINET - TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom (Recommended 27” to 30”) [(A – B) – (D + E)] D = Height of Hood E = Height of the Cabinet - FOR STAND ALONE (
Streszczenie treści zawartej na stronie nr. 8
SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. Installation Table of Contents UNDER THE CABINET INSTALLATION................................................................................6 Preparation Before Installation...................................................................
Streszczenie treści zawartej na stronie nr. 9
UNDER THE CABINET INSTALLATION Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long runs Figure 1 as possible. This may reduce the performance of the hood. • Tempo
Streszczenie treści zawartej na stronie nr. 10
Ductwork Installation 7. Use 8” aluminum or steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to seal and secure joints as shown in Figure 5. Wiring to Power Supply S AF E T Y W AR N I N G TO PREVENT THE RISK OF ELECTRICAL SHOCK OR Figure 5 INJURY, ALL RANGE HOODS SHOULD BE PROPERLY GROUNDED AND INSTALLED BY A TRAINED PROFESSIONAL WHO IS KNOWLEDGEABLE ABOUT AP
Streszczenie treści zawartej na stronie nr. 11
15. Install heating lamps (not provided), 120 Volts 175 Watts max. each. 16. Turn power ON in control panel. Check all lights and fan operation. 17. Make sure to leave this manual for the homeowner Figure 8 8
Streszczenie treści zawartej na stronie nr. 12
STAND ALONE INSTALLATION ***Follow these installations only if installing with an optional duct cover: Preparation Before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. • Decide the location of the venting pipe from the hood to the outside. Refer to Figure 9. • A straight, short vent run will allow the hood to perform more efficiently. • Try to avoid as many transitions, elbows, and long
Streszczenie treści zawartej na stronie nr. 13
2. Align hood-mounting bracket to the two screws WALL on the wall and hook hood into place. Tighten screws to secure hood to the wall. 3. For safety purpose, extra knockout holes on the back of the hood are provided for a more secure installation. Knock out as many holes as needed and secure with screws (not provided) from the inside of hood. CAUTION: MAKE SURE HOOD IS SECURE BEFORE RELEASING. Figure 13 Wiring to Power Supply SA
Streszczenie treści zawartej na stronie nr. 14
Duct Cover Installation 5. Use 8” aluminum or steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to seal and secure joints as shown in Figure 15. Slide the duct cover onto the hood. 6. Use 3/16” x 3/8” screws (provided) to attach duct cover to hood. Figure 15 Final Assembly CAUTION: Install heating lamps last. 7. Drop Oil Tunnel into suppo
Streszczenie treści zawartej na stronie nr. 15
OPERATING INSTRUCTIONS This KOBE hood is equipped with touch-sensor screen and features 3 minute delay shutoff, powerful centrifugal squirrel cage with baffle filters, bright 12-volt 20-watt halogen lights and heating lamp capability (heating lamps not included). The touch-sensor screen has Heat Lamp Control, Light Control, Speed Control (QuietMode™, Low, Medium and High), and Power Control. Refer to Figure 18. Heat Lamp Light Control Speed Control Power Control
Streszczenie treści zawartej na stronie nr. 16
Turn Off After 3 Minute Delay Gently touch the symbol under the Power Control sign once, the symbol flashes and after 3 minutes, the hood will turn off leaving only the sign lit. Speed Control: • There are four speeds: QuietMode™, Low, Medium, and High. To activate the speed, touch the control under the speed sign. For example, if turning on hood at low speed, gently touch the symbol under the sign. If you want to switch from low to high speed, touch the symbol under the sign and
Streszczenie treści zawartej na stronie nr. 17
MAINTENANCE SAFETY WARNING NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For optimal operation, clean range hood and all baffle/spacer/filter/oil tunnel/oil container regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve the appearance of the hood. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2. If hood looks splotchy (stainless steel hoo
Streszczenie treści zawartej na stronie nr. 18
To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL. 1. Make sure all controls are off, and range hood is unplugged. 2. Place a flat-head screwdriver between light cover and housing to remove cover . 3. Gently pull defective bulb straight out and discard. Light bulbs should be
Streszczenie treści zawartej na stronie nr. 19
SPECIFICATIONS MODEL / SIZE CH0130SQB / 30” CH0136SQB / 36” CH0142SQB / 42” CH0148SQB / 48” DESIGN 18-Gauge Seamless Commercial Stainless Steel CONSUMPTION / AMPERE 702W / 5.85A – 30”, 36” 722W / 6.02A – 42”, 48” VOLTAGE 120V 60Hz NUMBER OF MOTORS 1 FAN TYPE: CENTRIFUGAL Squirrel Cage EXHAUST Top Transition Rectangular to 8” Round x 1 CONTROLS Touch Sensor Screen HALOGEN LIGHTS 30” / 36” - 12V20W x 2 42” / 48” - 12V20W x 3 HEATING LAMPS 120V 175W Max. x 2 (Light Bulbs Not
Streszczenie treści zawartej na stronie nr. 20
8" (203) 2 - 1/8" (54) 1 - 7/8" (48) 1/ " (12 2 ) 1 - 1/4" (32) 6 - 1/2" (166) 4 - 1/2" (114) 1" (25) 12" (305) 24" (610) MEASUREMENTS & DIAGRAMS *** Inch measurements converted from millimeter. Inch measurements are estimated. - FOR UNDER THE CABINET - MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB 17 6 - 1/2" (165) 1 - 1/4"(32) 1 " ) 1 - /4 (32 12" (306) 1 - 1/4" (32) 3 " 36 4 " / 48" 0 / " / 2 18" (457) 3 - 1/8" (79.5)