Streszczenie treści zawartej na stronie nr. 1
415571-UTG-C-0309
DESCRIPTION
TECHNICAL The 13 SEER Series condensing unit is the outdoor part of a
TECHNICAL
versatile system of air conditioning. It is designed to be custom-
matched with one of UPG’s complete line of evaporator sec-
tions, with each serving a specific function. Matching Air Han-
GUIDE
GUIDE
dlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters are
available, if required. Add-on coils are available for use with
up
Streszczenie treści zawartej na stronie nr. 2
415571-UTG-C-0309 Physical and Electrical Data TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 MODEL S43S1 S43S1 S43S1 S43S1 S43S1 S44S1 S44S1 S44S1 S44S1 S44S1 Unit Supply Voltage 208-230V, 3 60Hz 460V, 3 60Hz 1 Normal Voltage Range 187 to 252 432 to 532 Minimum Circuit Ampacity 11.4 12.3 16.3 15.5 23.9 9.4 7.1 8.0 7.9 13.5 2 15 20 25 25 40 15 15 15 15 20 Max. Overcurrent Device Amps 3 15 15 20 20 25 15 15 15 15 15 Min. Overcurrent Device Amps Compressor Type R
Streszczenie treści zawartej na stronie nr. 3
415571-UTG-C-0309 System Charge for Various Matched Systems Outdoor Unit TCGD30S4(3,4)S1 TCGD36S4(3,4)S1 TCGD42S4(3,4)S1 TCGD48S4(3,4)S1 TCGD60S4(3,4)S1 1,2 0.061/4F1 0.065/4G1 0.075/4G1 0.073/4H1 0.087/4J1 Required Orifice or TXV Factory Charge, lbs-oz 3 - 14 4 - 9 4 - 5 4 - 9 5 - 6 3,4 Additional Charge, oz Indoor Coil AHP30 0–––– AHP36 20––– AHP42 –00–– AHP/SHP60 –––00 AHX30 0–––– AHX36 20––– AHX42 –82–– AHX48 –––0– AHX60 ––––4 F4FP024 ––––– F4FP036 ––––– F4FP040 0–––– F5FP048 –824– F5FP060
Streszczenie treści zawartej na stronie nr. 4
415571-UTG-C-0309 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL NET MBH RATED 1 MODEL MODEL MODEL W SEER EER CFM TOTAL SENS. 13 SEER AC WITH MA MA12B 17 FC/MC35B 1000 29.0 21.0 13.00 11.00 TCGD30S4(3,4)S1 MA12B 17 FC/MC43B 1000 29.0 21.0 13.00 11.00 MA12B 17 FC/MC43B 1200 35.0 24.8 13.00 11.00 TCGD36S4(3,4)S1 MA14D 24 FC/MC48D 1200 35.0 24.8 13.00 11.00 MA16C 21 FC/MC43C 1400 42.0 29.2 13.00 11.00 TCGD42S4(3,4)S1 MA14D 24 FC/MC48D 1400 42.0 29.2 13.00 11.00 MA16C
Streszczenie treści zawartej na stronie nr. 5
415571-UTG-C-0309 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL NET MBH UNIT MODEL CFM RANGE RATED 1 MODEL W SEER EER (Min.-max.) CFM TOTAL SENS. 800 - 1200 14 FC/MC/PC32 1000 29.0 21.0 13.00 11.00 800 - 1200 17,21 FC/MC/PC35 1000 29.0 21.0 13.00 11.00 800 - 1200 14 FC/MC/PC37 1000 29.0 21.0 13.00 11.00 TCGD30S4(3,4)S1 800 - 1200 17,21 FC/MC/PC43 1000 29.0 21.0 13.00 11.00 800 - 1200 17 HC36 1000 29.0 21.0 13.00 11.00 800 - 1200 21 HC42 1000 29.
Streszczenie treści zawartej na stronie nr. 6
415571-UTG-C-0309 COOLING CAPACITY - With High Efficiency Motor Furnaces COOLING UNIT FURNACE COIL W Net MBH RATED 1 MODEL MODEL MODEL SEER EER CFM TOTAL SENS. 2 13 SEER HP WITH VARIABLE SPEED FURNACES T*(8,L)X*A12 FC/MC/PC32A 14 970 29.2 21.4 13.20 11.00 T*(8,L)X*B12 FC/MC/PC35B 17 1120 30.0 22.8 14.00 11.50 T*(8,L)X*C16 FC/MC/PC35C 21 1105 30.0 22.8 14.00 12.00 T*(8,L)X*C20 FC/MC/PC35C 21 850 28.8 20.6 14.00 12.00 T*9X*B12 FC/MC/PC35B 17 1085 29.8 22.8 14.00 12.00 T*9X*C16 FC/MC/PC35C 21 1075
Streszczenie treści zawartej na stronie nr. 7
415571-UTG-C-0309 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING UNIT FURNACE COIL W Net MBH RATED 1 MODEL MODEL MODEL SEER EER CFM TOTAL SENS. 2 13 SEER HP WITH VARIABLE SPEED FURNACES T*(8,L)X*C16 FC/MC/PC48C 21 1600 48.0 34.4 13.30 11.00 T*(8,L)X*C20 FC/MC/PC48C 21 1660 48.0 34.4 13.20 11.00 T*9X*C16 FC/MC/PC48C 21 1565 48.0 34.8 13.10 11.00 T*9X*C20 FC/MC/PC48C 21 1615 48.0 34.4 13.20 11.00 T*9X*D20 FC/MC/PC48D 24 1635 48.0 34.8 13.20 11.00 T*(8,L)X*C16 FC/PC60C
Streszczenie treści zawartej na stronie nr. 8
415571-UTG-C-0309 ACCESSORIES SOUND POWER RATINGS* Refer to Price Manual for specific model numbers. UNIT (dBA) MODEL 230V 460V OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle to 30 76 76 prevent rapid recycling of the compressor. 36 76 76 ROOM THERMOSTATS - A wide selection of compatible ther- 42 77 76 mosets are available to provide optimum performance and fea- 48 77 77 tures for any installation. 60 78 78 1H/1C, manual changeover electronic non-programmable ther- * Rated in accordance w
Streszczenie treści zawartej na stronie nr. 9
415571-UTG-C-0309 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TGCGD30S4(3,4)S1 INDOOR COIL MODEL NO. FC/MC/PC35 IDCFM 800 1000 1200 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 28.4 31.4 30.8 33.1 34.4 29.8 31.8 31.4 33.4 34.5 31.2 32.3 32.1 33.7 34.7 65 S.C. 28.8 25.8 21.7 21.2 16.0 30.4 28.2 23.6 22.6 17.1 31.9 30.7 25.4 24.0 18.1 KW 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1
Streszczenie treści zawartej na stronie nr. 10
415571-UTG-C-0309 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD36S4(3,4)S1 INDOOR COIL MODEL NO. FC/MC/PC43 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 34.7 36.1 35.2 37.4 37.3 33.8 35.5 34.8 37.0 37.5 32.9 34.9 34.4 36.6 37.6 65 S.C. 34.3 33.0 27.6 25.5 18.4 33.3 31.0 26.2 24.6 18.0 32.3 29.1 24.7 23.6 17.7 KW 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.9 2
Streszczenie treści zawartej na stronie nr. 11
415571-UTG-C-0309 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD42S4(3,4)S1 INDOOR COIL MODEL NO. FC/MC/PC43 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 44.4 45.5 43.6 47.0 48.5 45.9 46.5 45.0 48.5 49.8 47.5 47.5 46.5 50.1 51.1 65 S.C. 41.5 35.6 29.7 28.7 21.5 42.9 37.5 31.4 30.2 22.9 44.4 39.4 33.2 31.7 24.3 KW 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.6 2.5 2
Streszczenie treści zawartej na stronie nr. 12
415571-UTG-C-0309 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD48S4(3,4)S1 INDOOR COIL MODEL NO. FC/MC/PC48 IDCFM 1400 1600 1800 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 49.7 51.4 50.6 55.8 54.6 52.0 53.1 51.9 56.4 55.4 54.4 54.7 53.2 56.9 56.3 65 S.C. 47.2 43.1 35.9 36.0 26.1 49.2 45.9 38.2 37.4 27.6 51.2 48.7 40.4 38.8 29.0 KW 2.7 2.8 2.8 2.8 2.8 2.7 2.8 2.8 2.8 2.8 2.7
Streszczenie treści zawartej na stronie nr. 13
415571-UTG-C-0309 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD60S4(3,4)S1 INDOOR COIL MODEL NO. FC/MC/PC60 IDCFM 1400 1600 1800 CONDENSING ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 55.8 63.8 62.1 65.2 71.9 60.3 65.7 62.8 66.7 69.8 64.8 67.5 63.5 68.2 67.8 65 S.C. 54.7 51.6 41.4 41.1 34.1 58.4 54.2 43.9 42.6 31.9 62.1 56.8 46.5 44.2 29.6 KW 3.0 3.0 3.0 3.1 3.1 3.0 3.0 3.0 3.1 3.1 3.0
Streszczenie treści zawartej na stronie nr. 14
Subject to change without notice. Printed in U.S.A. 415571-UTG-C-0309 Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes 415571-UTG-B-0708 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069