Streszczenie treści zawartej na stronie nr. 1
Kenmore
12,000 BTU Portable Air Conditioner, Dehumidifier & Heater with Remote Control
Use & Care Guide
Model: 35132
FOR HOUSEHOLD USE ONLY
1
Streszczenie treści zawartej na stronie nr. 2
Congratulations on purchasing your Kenmore Air-Conditioner, Dehumidifier & Heater unit. Your air-conditioner has been developed and manufactured in accordance with standards of state of the art technology. Please read the operating instructions carefully before connecting your unit to the power supply in order to prevent damage from improper use. Pay special attention to the safety instructions. If you pass this unit on to a third party, you should also include these operating instructio
Streszczenie treści zawartej na stronie nr. 3
Use a soft cloth to clean. Do not use wax, thinners or a strong detergent. The appearance of the air conditioner may deteriorate, change color or develop surface flaws. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. When water enters the product, turn off the power switch of the main body of the appliance. For repair and maintenance, contact an Authorized Service Centre. For warranty, refer to the
Streszczenie treści zawartej na stronie nr. 4
UNPACKING INSTRUCTIONS 1. Place the unit in the correct upright position before unpacking. 2. Cut the two packing straps. 3. Slide the carton in an upwards motion and it will release from the base. (We recommend that you retain the packaging for off season storage) 4. Grip the carry handles located on either side of the unit and carefully lift until it slides out of the foam base. 5. Disconnect the tie-in inside the exhaust tube and take out the exhaust tube.
Streszczenie treści zawartej na stronie nr. 5
INSTALLATION Prior to installing the unit, check for the following: 1. To avoid damage, place the unit in an upright position for at least 12 hours before initial set-up. 2. Release the exhaust hose holder in the unit and take out the exhaust hose. 3. Fasten the exhaust hose before turning the unit on. 4. Expand the exhaust hose, then turn in the direction of the arrow displayed and remove it from the unit. 5. Expand the exhaust hose, then turn in the direction of the
Streszczenie treści zawartej na stronie nr. 6
Figure 1 Figure 1a Window slider kit Window slider kit Min: 55 cm Min: 55 cm Max:127cm Max:127cm Vertical Horizontal Window Window SAFETY PLUG The appliance is equipped with an LCDI safety plug to protect the unit. If power is cut off, unplug from the socket and make sure the power cable is undamaged. If the cable is damaged, call the service center immediately. If power cuts off frequently and the power cable is
Streszczenie treści zawartej na stronie nr. 7
CONTROL PANEL 1. POWER Press this button to switch the unit on or off 2. MODE Press this button to select between Cooling ( ), Heating ( ) or Dehumidifying ( ) mode 3. REMARKS: PRESS [MODE] IN STANDBY MODE (UNIT IS PLUGGED IN BUT NOT IN OPERATION, NO DISPLAY ON THE PANEL) FOR 10 SECONDS TO SWITCH DISPLAY BETWEEN FAHRENHEIT AND CELSIUS. TEMP+ Pressing this button in cooling mode adjusts the required room temperature by 1°C up to a maxi
Streszczenie treści zawartej na stronie nr. 8
6. SPEED Pressing this button sets the ventilation speed to “ (low)”, “ (medium)”, “ (high)” or “AUTO (Automatic)”. If “AUTO” is selected, the ventilator operates at temperature differences larger than 9 degrees at top speed. If the temperature reduces to a difference smaller than 4 degrees, the ventilator switches to middle blower position. If the temperature reduces further until the target temperature, the ventilator switches to the lowest blower position. 7. TIMER Programmable
Streszczenie treści zawartej na stronie nr. 9
REMOTE CONTROL INSERTING OR REPLACING THE BATTERIES - This remote control uses two AAA batteries. Remove the back cover of the remote control. Insert two “AAA” 1.5V batteries, making sure they are in the correct position (see instructions inside the battery compartment) Replace the cover. Do Not Mix Old And New Batteries. Do Not Mix Alkaline, Standard (Carbon - Zinc), or Rechargeable (Nickel - Cadmium) Batteries. Dispose of old batteries properly. Do not leave batteries
Streszczenie treści zawartej na stronie nr. 10
OPERATING INSTRUCTIONS Note: After switching the unit on, the ventilator operates, but the compressor only starts after the control lamp has flashed for 3 minutes. Cooling effect may require a further 5 minutes. This is done as a protection mechanism to prolong compressor life. Further information is available in the “Troubleshooting” section. AIR CONDITIONING MODE – IN ROOM OPERATION We recommend starting your unit early in the morning on warm days for maximum effect. This unit
Streszczenie treści zawartej na stronie nr. 11
If the unit is to be placed outside of the room to be cooled, you should try to position the unit on a flat solid surface and in an area protected from rain and sun exposure such as sunroom, veranda or hallway. You should not operate the unit in moist areas, such as e.g. saunas or similar areas. The colour of the unit can change slightly due to direct solar radiation. The unit is equipped with a special thermal deactivation. This protects the unit from overheating in extreme ambient c
Streszczenie treści zawartej na stronie nr. 12
The cold extract air has to be vented out of the room via the air hose. This can be executed via a tilted window, a door or wall aperture. Make sure that no cold outside air can enter the room. Set the function to “HEATING“. The settable temperature range is between 15°C and 25°C. You can set this using the temperature control. Note: In the heating mode, the ventilation level is already preset to ensure efficient heating of ambient air. You will not be able to
Streszczenie treści zawartej na stronie nr. 13
B) CLEANING THE FILTER Clean the air filter once every two weeks to remove dust build-up and keep the fan in top performance. Remove the filter: Pull out the filter cover and remove the air filter from the filter cover. Cleaning: Wash the air filter by immersing it in lukewarm water with a mild detergent. Rinse the filter and dry it in a dark place. Do not put in direct sunlight. Replace the filter: Attach the filter to the filter cover using the attachment hooks
Streszczenie treści zawartej na stronie nr. 14
TROUBLESHOOTING If your air conditioner fails to operate, please follow these procedures prior to contacting customer service. PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE AIR CONDITIONER YOURSELF. DOING SO COULD VOID THE WARRANTY AND CAUSE DAMAGE OR PERSONAL INJURY. PROBLEM POSSIBLE COUSE SOLUTION Can I turn the unit on immediately No. The unit must be placed upright for at after unpacking it? least 12 hours after every transport. Otherwise the compressor may be dam
Streszczenie treści zawartej na stronie nr. 15
areas). Run the unit for ½ a day. The smell will disappear after a while. In the case of intensive odor development air the room. Compressor does not activate Depending on ambient temperatures and unit type it may take approx. 10 minutes after starting the compressor until the cooling/heating capacity is reached. The unit deactivates On reaching the set required temperature, the unit switches off automatically. Check manual setting of the required temperature as well as the TIM
Streszczenie treści zawartej na stronie nr. 16
1-YEAR WARRANTY (PARTS/LABOUR) 5-YEAR WARRANTY (COMPRESSOR ONLY) VALID ONLY WITH ORIGINAL PURCHASE RECEIPT Warranty: We warrant this product against defects in any parts or workmanship for a period of 1 year (parts/labor) and 5 years (compressor only) from the original purchase date. Parts that prove to be defective during the 1- year period will either be repaired or replaced at our option. No charge will be made for such repair or replacement. The right is reserved by the manufactu