Streszczenie treści zawartej na stronie nr. 1
Owner's Manual
Manual del Propietario
®
ROOM AIR CONDITIONER
ACONDICIONADOR DE AIRE DE VENTANA
Model, Modelo 580.72053
Sears, Roebuck and Co., Hoffman Estates, IL 60__'3J.S."A.
www.sears.com
Streszczenie treści zawartej na stronie nr. 2
Features ................................................... 9 TABLE OF CONTENTS ........................ 2 Using the Air Conditioner ......................... 9 WARRANTY .............................................. 2 Air Conditioner Features ........................ 10 SAFETY ..................................................... 3 MAINTENANCE ..................................... 11 Important Safety Instructions...................... 3 Air Filter Cleaning ................................... 1
Streszczenie treści zawartej na stronie nr. 3
IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER. FOR YOUR SAFETY Do not store or use gasoline or other flammable _ Avoid fire hazard or electric shock. vapors and liquids in the vicinity of this or any other Do not use an extension cord or an adapter plug. appliance. Read product labels for flammability and Do not remove any prong from the power cord. other warnings. _
Streszczenie treści zawartej na stronie nr. 4
OBSERVE ALL LOCAL CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVETHEPOWERSUPPLYCORD GROUND PRONG. ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE. A 115-volt 60 Hz, AC only, 15A fused and Electrical Shock Hazard properly grounded electrical supply is required. Plug into a grounded 3 prong outlet. A time delay fuse or time delay circuit breaker Do not remove ground prong. is recommended. Use a dedicated circuit, Do not use an adapter. serving only this appliance. Do not use an exten
Streszczenie treści zawartej na stronie nr. 5
INSTALLATION HARDWARE INSTALLATION REQUIREMENTS ITEM B: 4EA ITEM A: 11EA Your air conditioner will install into standard double SHORT SCREW WOOD SCREW hung windows with actual clear opening widths of 22 to 36 inches (558mm to 914mm) (FIG. 1). Lower sash must open sufficiently to allow a clear !, vertical opening of 14 inches (356mm). Side louvers and the rear of the air conditioner must have clear ITEM C: 3EA ITEM D: lEA air space to allow enough air[low through the SEAL STRIP L BRACKET condense
Streszczenie treści zawartej na stronie nr. 6
INSTALLATION L_ ATTACH L BRACKET • Install the L brackets on the outer sill with the short Pick a location which will allow you to blow the cold side of the bracket against the back of the inner air into the area you want. Windows used for sill. Install one L bracket 8" to each side of center installation must be strong enough to support the weight of the air conditioner. Good installation with line. See FIG. 5. special attention to the proper position of the unit • The bracket helps to hold uni
Streszczenie treści zawartej na stronie nr. 7
I_l INSTALL THE AIR CONDITIONER IN THE I_IIF AIR CONDITIONER IS BLOCKED BY WINDOW STORM WINDOW FRAME • Carefully lift the air conditioner and slide it into the • If storm window presents interference, fasten a 2" open window. Make sure the bottom guide of the air wide wood strip to the inner window sill across the full conditioner drops into the notches of the L brackets. width of the sill. The wood strip should be thick enough to raise the height of the window sill so that • When the air condit
Streszczenie treści zawartej na stronie nr. 8
HOW AND WHY Compressor Your room air conditioner provides the following The modern high efficiency functions to make hot weather living more compressor may have a high comfortable: pitched hum or pulsating • Cools and circulates room air. noise that cycles on and off. • Lowers humidity by removing excess moisture. -Fan Unit Vibration • Filters out summertime dust, dirt, and some You may hear air , vibrate airborne impurities. movement from the and make noise fan. because of poor wall The air con
Streszczenie treści zawartej na stronie nr. 9
FEATURES USING THE AIR CONDITIONER _To reduce the risk of fire, electric shock, or injury to persons, read the important SAFETY instructions section before operating this 7 1 appliance. To begin operating the air conditioner after installation, follow these steps: 1. Plug in the air conditioner. (To prevent electrical hazards, do not use an extension cord or an adapter plug.) 2. Set the TEMP control to the coolest setting. 3. Set the MODE control at the highest COOL level. 4. Adjust the louvers
Streszczenie treści zawartej na stronie nr. 10
AIR DIRECTION ADJUSTMENT AIR CONDITIONER FEATURES Using the Control Tabs, the air flow can be directed The controls featured in this manual are to the left, right, straight ahead, or any combination representative of the many models available. Your of these directions. model may look slightly different. OFF HIGH _ HIGH ""if ,I,\"t LOW II II I\ _\ LOW FAN e_OCOOL MODE FIG. 14 _s 3e 4e e6 e7 2e_ e8 TEMP FIG. 13 TEMP The thermostat will automatically control the temperature of the room. Select a h
Streszczenie treści zawartej na stronie nr. 11
HOW TO REMOVE THE FRONT AIR FILTER CLEANING GRILLE The Air Filter will become dirty as it removes dust from the inside air. It should be washed at least • Remove the TEMP knob and the MODE knob by every 2 weeks. If the Air Filter remains full of dust, pulling. the air flow will decrease and the cooling capacity • Remove the screw securing the Front Grille. will be reduced, possibly damaging the unit. • Push the grille up from the bottom and pull the top • Pull the inlet grille forward and pull o
Streszczenie treści zawartej na stronie nr. 12
BEFORE CALLING FOR SERVICE Check the following list to be sure a service call is really necessary. A quick reference to this manual may help you avoid an unneeded service call. THE AIR CONDITIONER WILL NOT OPERATE Check if... Then... Housefuse blownorcircuitbreakertripped. Replacefusewithtimedelaytypeorresetdrceit breaker. MODEselectoris OFFposition. TurnMODEselectortothedesiredCOOLset_ng. Unitwas temedoffandthenontonquickly. Turnunitoffandwait3 minutesbeforerestarti_. Wall plugdisconnected. t u
Streszczenie treści zawartej na stronie nr. 13
Streszczenie treści zawartej na stronie nr. 14
Room Air Conditioner To order Parts call Toll Free Model No. 580.72053100 1-800-4-MY-HOME®(1-800-469-4663) CAUTION: Use the Kenmore part number on all orders, not the illustration number. CABINET & FRONT GRILLE ASS'Y -- 3-A 11/00 - 14 -
Streszczenie treści zawartej na stronie nr. 15
580.72053100 CAUTION: Use the Kenmore part number on all orders, no..._t the illustration number. CABINET & FRONT GRILLE ASS'Y POS. NO PART NO DESCRIPTION 1 - A 3091A10020A CABINET ASS'Y 2 - A 4941AR3813A KNOB ASS'Y 3 - A 3530AR1343A GRILLE, INLET 4 - A 5231AR2148A AIR FILTER ASS'Y 5 - A 3530AR1344A GRILLE, FRONT 6 - A 5900AR3190B VANE 7 - A 5900AR3190A VANE 8 - A 4520AR3191A LINK HOLDER 9 - A 5210AR3196C UPPER GUIDE 10 - A 3850A20043T ENERGY GUIDE LABEL 3828A20049Y OWNER'S MANUAL # = Functional
Streszczenie treści zawartej na stronie nr. 16
580.72053100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. CONTROL BOX ASS'Y 1-B 6-B 11-B IO-B F-B- 8-B 11/00 - 16 -
Streszczenie treści zawartej na stronie nr. 17
580.72053100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. CONTROL BOX ASS'Y POS. NO PART NO DESCRIPTION 1 - B # 2H00677P POWER CORD ASSY 2 - B 4H01254A CLIP 3 - B 6877A20001G LEAD WIRE ASSY 4 - B 6631AR3843R CONDUCTOR ASSY 5 - B # 2H01109H THERMOSTAT ASSY 6- B # 2H00154H SWITCH, ROTARY 7 - B 4H00442F CLAMP, CAPACITOR 8 - B # 6120AR2359V CAPACITOR 9 - B 2H01045E CONDUCTOR ASSY 10 - B 4994A20016A CONTROL BOX, SINGLE 11 - B 3550A20026A COVER # = Functional Parts
Streszczenie treści zawartej na stronie nr. 18
580.72053100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. AIR HANDLING & CYCLE PARTS 10-C 2-C -- 6-C 11/00 - 18 -
Streszczenie treści zawartej na stronie nr. 19
580.72053100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. AIR HANDLING & CYCLE PARTS POS. NO PART NO DESCRIPTION EVAPORATOR ASSY 1 -C # 5421AI0008B 2-C 3H02932B CLAMP, SPRING 3- C # 5900A20005A FAN, TURBO 4- C 5239A30003A AIR GUIDE, LOWER 5- C 5238A20004A AIR GUIDE, UPPER 6- C 3041A10011E BASE ASSY, SINGLE 7- C # 4681A10002A MOTOR ASSY, SINGLE 8- C 4998A10006A SHROUD 9- C # 5900A20006A FAN, PROPELLER 10-C # 5403A20038D CONDENSER ASSY 11- C 4948A10007A ORIFICE
Streszczenie treści zawartej na stronie nr. 20
580.72053100 CAUTION: Use the Kenmore part number on all orders, no___tt the illustration number. COMPRESSOR PARTS 1-D 2-D 10-D 3-D 6-D 11/00 - 20 -