This air conditioner provides with cooling, heating, and drying functions. Details of the functions are below; refer to these descriptions when using the air conditioner. Compact Size Air Sweep Control This model is smaller than its predecessors and This function moves a flap up and down in the air yet offers the same capabilities. outlet, directing air in a sweeping motion around the room and providing comfort in every corner. Microprocessor Controlled Operation
Streszczenie treści zawartej na stronie nr. 3
Contents Pardon not to inform you if the contents of the manual changes. Page Alert symbol 1 Caution statements 2 Composition of the air conditioner 3 Operation guide 8 Care and cleaning 16 Tips for energy saving 18 Troubleshooting 18 Schematic diagram
Streszczenie treści zawartej na stronie nr. 4
Caution Statements 1.We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the installation WARNING instructions provided with the unit. 2.Before installation, check if the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. WARNING 3.Do not install the air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenh
Streszczenie treści zawartej na stronie nr. 5
Composition of the Air Conditioner 1.Diagram of Structure Air intake grille INDOOR UNIT Air outlet Drain hose Remote control Refrigerant tubes unit OUTDOOR UNIT Air outlet This air conditioner consists of an indoor unit and an outdoor unit. You can NOTE control the air conditioner with the remote control unit. Air from the room is drawn into this section and passes Air Intake through air filters which remove dust. Conditionedairisblownoutoftheairconditionerthrough Air Outlet thea
Streszczenie treści zawartej na stronie nr. 6
2.Introduction of the Indoor ControI Unit INDOOR UNIT OPERATING lamp TIMER lamp POWER lamp IMPORTANT: POWER HIGH POWER TIMER Avoid using radio equipment lamp OPERATING such as mobile phone near (within 1m) the indoor unit. Some radio equipment may cause maIfunction of the unit. If the troubIe happens, dis- connect power and restart the air conditioner after a few REMOTE CONTROL receiver ON/OFF button minutes. REMOTE CONTROL This section pic
Streszczenie treści zawartej na stronie nr. 7
3.Introduction of Display Displayed when setting temperature S SE ET T T TE EM MP P Displayed when transmitting data AUTO C Displayed when temperature is shown Displayed when temperature setting is at the upper or lower allowable limits Simultaneous use energy saving 1 A 1HOUR Displayed when Night Setback is Displayed when one-hour running OFF timer is enable Displayed when main unit sensor is in HOUR AUTO use ON Displayed when setting timer AUTO OFF Symbols (4) Timer (1) Operation mode
Streszczenie treści zawartej na stronie nr. 8
4.Introduction of the Remote control Unit SENSOR Transmitter SET TEMP AUTO C 1 A 1H 1HOU OUR R x HOUR HOUR AUTO Display AUTO TEMP 1HR ON/OFF 1 HR. TIMER button TEMP.setting button HIGH POWER HIGH POWER button ON/OFF button FLAP MODE FLAP button MODE selector button ON OFF FAN SPEED FAN SPEED selector button TIMER ON/OFF button SLEEP CANCEL SOFT SET NIGHT SETBACK button BATTERY TIMER SET/CANCEL A/C SENSOR ACL button A/C SENSOR button ACL button (Cover closed) SIMULTANEOUS EMERGY SAVING
Streszczenie treści zawartej na stronie nr. 9
Remote Control Unit(continued) TIMER ON button :The air conditioner starts at the set time. TIMER OFF button :The air conditioner stops at the set time. TIMER SET/CANCEL button This button is used to set/cancel the time at which you wish the air conditioner to go on or off. MODE selector button Use this button to select AUTO, HEAT, DRY, COOLING or FAN mode. (AUTO) AUTO :When this setting is selected, the air conditioner calculates the difference between the
Streszczenie treści zawartej na stronie nr. 10
Operation Guide HOW TO INSTALL BATTERIES 1. Slice the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries, make sure the batteries point in the direction m arked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. ACL button B B A Replace the batteries when the remote control unit's display fails to light, NOTE or when the remote control unit cannot be used to change the air ! ,
Streszczenie treści zawartej na stronie nr. 11
Operation with the Remote control Unit(continued) C AUTO AUTO 1HR TEMP ON/OFF STEP 3 STEP 2 HIGH POWER FLAP MODE STEP 5 STEP 1 FAN ON OFF SPEED STEP 4 SET CLR SOFT SLEEP BATTERY A/C SENSOR ACL Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is NOTE in the ON position. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the setting as desired. Press
Streszczenie treści zawartej na stronie nr. 12
Adjusting the Fan Speed A. Automatic AUTO Simply set the FAN SPEED selector to the position. AUTO A microcomputer in the air conditioner will automatically control the fan speed when the mode is selected. When the air conditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is detected by the microcomputer which then automatically switches the fan speed to the most suitable level. Cooling mode: When difference
Streszczenie treści zawartej na stronie nr. 13
Adjusting the Airflow Direction 1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes wit your hands to the left or right. When the humidity is high, the vertical vanes should be in the front CAUTION position during the cooling or dehumidifying operation. If the vertical ! vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down. 2. Vertical The vertical airflow can be adjusted by mo
Streszczenie treści zawartej na stronie nr. 14
Night Setback / Simultaneous Use Energy Saving ¡ñNight Setback Mode Night Setback Mode is used for saving energy. Press the SLEEP button in operation. The mark apperars in the display. To release the night Setback function, press the SLEEPbutton again. C NOTE This function loses is automation or airflow mode. B.In Cooling and DRY Mode: AUTO When the night setback mode is sescted, the air conditioner AUTO automatically raises the temperature, setting 1¡æ w
Streszczenie treści zawartej na stronie nr. 15
Using the 12-Hour ON and OFF Timer 1.TIMER ON mode After the length of timer set for TIMER ON elapses, the unit begins operating. (Example) The display depicted at left lindicates that the air conditioner will begin operating in three hours. Setting Procedures: C Press the MODE button and set the desired operation mode and STEP 1 HO HOUR UR press the ON/OFF operation button. STEP 2 Press the timer ON button to set the time at which you want operation to begin. The time can be set fo
Streszczenie treści zawartej na stronie nr. 16
Using the 1-Hour OFF Timer This function causes the system to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. 1HOUR 1HOUR The " " indicator in the display indicates that this function is operating. Setting procedures: C Regardless of whether the unit is operating or stopped, press the 1 HR .TIMER button. " " appears In the display. 1HOUR 1HOUR 1H 1HOU OUR R AUTO AUTO Cancellation procedures: 1HR TEMP ON/
Streszczenie treści zawartej na stronie nr. 17
Special Remarks Heating ( ) Operation Heating performance ¡ñ Because this air conditioner heats a room by drawing on the heat of the outside air (Heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance in conjunction with it. ¡ñ When the outdoor temperature is low, frost or ice may from in the heat exchanger Defrosting c
Streszczenie treści zawartej na stronie nr. 18
Operation without the Remote Contorol Unit INDOOR UNIT If you have lost the remote control unit or it has trouble, follow the steps below. 1.When the air conditioner is not running POWER HIGH POWER If you want to turn on the air conditioner, switch the operation selector to the TIMER OFF position, and then to the ON position. OPERATING 2.When the air conditioner is running If you want to turn off the air conditioner, switch the operation selector to the OFF position. ON/OFF button
Streszczenie treści zawartej na stronie nr. 19
Care and Cleaning (continued) Anti-Mold Filter The anti-mode filter behind the air intake grille should be cheched and cleaned at least once every three weeks. How to remove the 1.Grasp both ends of the air intake grille and pull it out and up. anti-mold filter 2.Push the anti-mold filter up slightly, and then pull it down. Air intake grille Anti-mold filter Anti-Mold Filter Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, Cleaning wash the filter in lukewarm
Streszczenie treści zawartej na stronie nr. 20
Tips for Energy Saving Do not ¡ñ Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. ¡ñ Let sunlight directly into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer time to cool the room. ¡ñAlways try to keep the air filter clean. (Refer to¡°Care and Cleaning¡±.)A Do clogged filter will impair the performance of the unit.