Streszczenie treści zawartej na stronie nr. 1
www.GEAppliances.ca
Safety Instructions . . . . . . . . . 2, 3
Owner’s Manual and
Installation Instructions
Operating Instructions
Light Controls . . . . . . . . . . . . . . . .4
PVWS930
Vent Controls . . . . . . . . . . . . . . . .4
PVWS936
PVWT936
Care and Cleaning
PVWG936
Grease Filters . . . . . . . . . . . . . . . .5
Hood Lights . . . . . . . . . . . . . . . . .6
PVIG940
Hood Surfaces . . . . . . . . . . . . . . . .5
Stainless Steel Surfaces . . . . . . . . .5
Installation Instructions . .
Streszczenie treści zawartej na stronie nr. 2
IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. SAFETY PRECAUTIONS WARNING – TO REDUCE THE RISK OF WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, INJURY TO PERSONS IN THE EVENT OF A OBSERVE THE FOLLOWING: RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: A. Use this unit only in the manner intended by the manufacturer. If you have A. SMOTHER FLAMES with a close-fitting questions, contact the manufacturer. lid, cookie sheet, or metal tray, then turn off
Streszczenie treści zawartej na stronie nr. 3
Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support www.GEAppliances.ca SAFETY PRECAUTIONS D. Ducted fans must always be vented to the WARNING – TO REDUCE THE RISK OF outdoors. A RANGE TOP GREASE FIRE: A. Never leave surface units unattended at WARNING – TO REDUCE THE RISK OF high settings. Boilovers cause smoking and FIRE, USE ONLY METAL DUCTWORK. greasy spillovers that may ignite. Heat oils Do not attempt to repair or replace any slowly on low o
Streszczenie treści zawartej na stronie nr. 4
Using the hood controls. Throughout this manual, features and appearance may vary from your model. AB DFCE GH I A - MOTORSTOP H - LED TIMED INTENSIVE SPEED B - SPEED DECREASE I - “ON-OFF’ LIGHT - MOTOR OPERATING PERFORMANCE CHECK- D - LED:SPEED 1 UP. WHEN ANY OF THE BUTTONS ARE F - LED: SPEED 2 AND METAL FILTER SATURATION PRESSED, ALL FOUR LEDS TURN ON TO (WHEN FLASHING) INDICATE THAT THE FOUR FAN SPEEDS C - LED: SPEED 3 AND COAL FILTER SATURATION OPERATE PROPERLY. IF ONE OF THE LIGHTS (WHEN FLA
Streszczenie treści zawartej na stronie nr. 5
Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Care and cleaning of the vent hood. www.GEAppliances.ca Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the vent hood. Make sure lamps are cold before cleaning the hood. To clean the filter/s We recommend you wash the filters at least once a month, by hand or in the dishwasher. Let the water drip out of the holes on the edges and leave the filters
Streszczenie treści zawartej na stronie nr. 6
Care and cleaning of the vent hood. Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the vent hood. Replacement of lamps (Models PVWS930, PVWS936, PVWT936, PVWG936, PVIG940) Unscrew the lamp diffusers. Remove the blown lamp and replace it with a new 20 Watt (max) 12 Volt halogen lamp with a G-4 cap. Follow the instructions given on the lamp box. Do not touch the lamp with your bare hands. Fig. 3 Place the lamp diffuser back in place. 6 Consumer S
Streszczenie treści zawartej na stronie nr. 7
Installation Range Hood Instructions Questions? Call 1-800-561-3344 or Visit our Website at: www.GEAppliances.ca CAUTION: BEFORE YOU BEGIN Due to the weight and size of these vent hoods and to Read these instructions completely and carefully. reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE REQUIRED FOR • IMPORTANT – Save these PROPER INSTALLATION instructions for local inspector’s use. • IMPORTANT – Observe all governing codes and ordinances. • Note to Installer – Be
Streszczenie treści zawartej na stronie nr. 8
Installation Instructions PRODUCT DIMENSIONS 13.4” 12” 13.4” 12” PVWG936 PVIG940 15.7” 24.8” 15.7” 24.8” 5.9” 10.8” PVWS930 5.9” 10.8” PVWS936 PVWT936 38.6” min. 53.7” max. 15.75” 36” 19.3” MODEL W D H T PVWS930/936 30” - 36” 19.3 33” - 45.3” 15.75” PVWT936 36” 19.3 38.6” - 53.7” 15.75” PVWG936 36” - 42” - 48” 19.7” 33.4” 17.7” PVIG940 39.4” 27.5” 33.4” - 48” 17.7” 1 Ft = 0.3 m 1” = 2.5 cm 8 2.5” 2.5”
Streszczenie treści zawartej na stronie nr. 9
Installation Instructions Total DUCT FITTINGS Equivalent Quantity Equivalent Duct Piece Dimensions Length* Used Length Use this chart to compute maximum permissable lengths for duct runs to 1 ft. outdoors. Round, (per foot straight length Note: Do not exceed maximum permissable 1 ft. equivalent lengths! 3¼” x 12” (per foot straight length Maximum duct length: 100 foot for vent hoods. Flexible ducting: 90° elbow 8 ft. If flexible metal ducting is used, all the equivalent feet values in the table
Streszczenie treści zawartej na stronie nr. 10
Installation Instructions TOOLS AND MATERIALS REQUIRED OPTIONAL ACCESSORIES (NOT SUPPLIED) ■ Kit 01235 Model PVIG940 Chimney + Structure 84 - 121.5 cm (Venting) ■ Kit 01237 Model PVWG936 Chimney 51.5 cm ■ Kit 01238 Model PVWT936 Chimney 70 - 140 cm (Venting) ■ Kit 01239 Models PVWS930/936 Pencil and Phillips and Duct tape Chimney 92.5 - 132 cm (Venting) tape measure Flat blade screwdrivers Ductless Recirculating Kit ■ Kit 01378 Models PVWS930/936, PVWT936 Carbon Filter + Filtrating Deflector
Streszczenie treści zawartej na stronie nr. 11
Installation Instructions PARTS PROVIDED - Continued DUCTING OPTIONS AND EXAMPLES Closely follow the instructions set out in this manual. MODEL PVWG936 All responsibility, for any eventual inconveniences, Hood canopy with internal blower, grease filters and damages or fires caused by not complying with the lights already installed instructions in this manual, is declined. Glass vapour catcher Duct covers Venting Methods Duct Cover support bracket The hood is equipped with a transition B
Streszczenie treści zawartej na stronie nr. 12
Installation Instructions 9. Models PVWS930/936 and PVWT936: WALL INSTALLATION Attach the 2 hooks with leveling screws (provided in the FOR MODELS PVWS930, PVWS936, PVWT936 AND assembly kit) to the points marked on the template with 2 screws and then remove the template. PVWG936 ONLY Model PVWG936: (For model PVIG940 installation, please refer to the Screw 2 screws on lower fixing point but do not tighten paragraph "CEILING INSTALLATION" on the next pages). them completely (leave a space of ½")
Streszczenie treści zawartej na stronie nr. 13
Installation Instructions WALL INSTALLATION - Continued Ø 3.5 x 9.5 13. Model PVWG936: Fix the 2 supplied brackets on the rear side of the motor housing with 4 screws each. Models PVWS930/936 and PVWT936 Lower Support Bracket Ø 3.5 x 9.5 Ø 3.5 x 9.5 Model PVWG936 14. Hang hood with the 2 mounting hooks (screws). WARNING Excessive Weight Hazard - Use two or more people to move and install range hood. Failure to do so can result in back or other injury. 15. Hang hood with the 2 mounting hooks (scr
Streszczenie treści zawartej na stronie nr. 14
Installation Instructions Model PVWG936 WALL INSTALLATION - Continued Ø 3.5 x 9.5 Run 3 wires; black, white and green ,according to the Duct Cover National Electrical Code and local codes and ordinances, in ½" conduit from service panel to Models PVWS930/936 and PVWT936 junction box. Duct Cover Ø 3.5 x 9.5 Connect black wire from service panel to black or red in junction box, white to white and green to green- yellow. Close and secure junction box cover. 20. Check all light bulbs to make sure th
Streszczenie treści zawartej na stronie nr. 15
Installation Instructions Note the position of the front part of the hood and CEILING INSTALLATION proceed with the installation. FOR MODEL PVIG940 ONLY Note: All fastener location must span the studs otherwise proceed as described in Step 4. (For models PVWS930/936, PVWT936 and PVWG936 4. Remove the template and keep it. Cut the dry wall of installation, please refer to paragraph "WALL the ceiling and remove it. Install some wooden strips of INSTALLATION" on previous pages). suitable length 2”
Streszczenie treści zawartej na stronie nr. 16
Installation Instructions Continued CEILING INSTALLATION - Ø 6 x 80 Ø 3.5 x 9.5 11. Insert the other chimney and keep it raised. Fix the low connector to the connection box. Then fasten the outlet duct onto the transition. 12. Bring the canopy together with the telescopic structure, and fasten them together using 4 screws (M8 x 16). Then you can carry out the electrical connection (consult Step 19 of “WALL INSTALLATION” instructions on previous page). 13. Lower the chimney and fasten it on the
Streszczenie treści zawartej na stronie nr. 17
Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Notes. www.GEAppliances.ca 17
Streszczenie treści zawartej na stronie nr. 18
Before you call for service… Troubleshooting Tips Save time and money! Review the charts on the following pages rst and you may not need to call for service. P r o b l e m P o s s i b l e Causes What To Do Fan does not operate A fuse may be blown or a • Replace fuse or reset circuit breaker. when the switch is on circuit breaker tripped. Fan fails to circulate air Excessively soiled lters. • Remove the lters, clean if necessary and replace or moves air slower than them. If cle
Streszczenie treści zawartej na stronie nr. 19
Please place in envelope and mail to: Veuillez mettre dans une enveloppe et envoyez à : OWNERSHIP REGISTRATION P.O. BOX 1780 MISSISSAUGA, ONTARIO L4Y 4G1 (FOR CANADIAN CONSUMERS ONLY - POUR RÉSIDENTS CANADIENS SEULEMENT) 19
Streszczenie treści zawartej na stronie nr. 20
OWNERSHIP REGISTRATION CERTIFICATE – FICHE D’INSCRIPTION DU PROPRIÉTAIRE Please register your product to enable us to contact you in Veuillez enregistrer votre produit afin de nous permettre de the remote event a safety notice is issued for this product communiquer avec vous si jamais un avis de sécurité concernant and to allow for efficient communication under the terms of ce produit était émis et de communiquer facilement avec vous en our warranty, should the need arise. vertu de votre gar