Streszczenie treści zawartej na stronie nr. 1
WET/DRY VACUUM BLOWER
5 GAL. CAPACITY
Model 94282
ASSEMBLY AND OPERATING INSTRUCTIONS
Do to continuing improvements, actual product may differ slightly from the product described herein.
®
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at: http://www.harborfreight.com
TO PREVENT SERIOUS INJURY,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
© ®
Copyright 2006 by Harbor Freight Tools . All rights reserved. No portion of this manual or
any artwor
Streszczenie treści zawartej na stronie nr. 2
PRODUCT SPECIFICATIONS Electrical Requirements 120 VAC / 60 Hz / 8 Amp / 3 HP Peak Power Plug 3-Prong, Grounded Power Cord 18 AWG x 3 C x 100” Long Power Switch 2-Position Rocker w/Clear Plastic Cover Tank Capacity 5 Gallons 1 Air Flow Capacity 125 Cubic Feet @ 2 / ” Orifice 2 Additional Features Float Valve to Stop Wet Vacuuming When Tank is Full Built-In Storage for Power Cord and Accessories Four Swivel Casters Accessories Three Extension Wands / One Crevice Tool One Floor Nozzle / One Filter
Streszczenie treści zawartej na stronie nr. 3
ELECTRICAL SAFETY 1. Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. If the tools should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user. 2. Double
Streszczenie treści zawartej na stronie nr. 4
4. Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the power tool in unexpected situations. 5. Use safety equipment. Always wear eye protection. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions. TOOL USE AND CARE 1. Do not force the tool. Use the correct tool for your application. The correct tool will do the job better and safer at the rate for which it is desig
Streszczenie treści zawartej na stronie nr. 5
SPECIFIC SAFETY RULES 1. Maintain labels and nameplates on the Vacuum Blower. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replace- ment. 2. Always wear safety impact eye glasses when assembling and using the Vacuum Blower. Using personal safety devices reduce the risk for injury. 3. Maintain a safe working environment. Keep the work area well lit. Make sure there is adequate surrounding workspace. Always keep the work area free of ob
Streszczenie treści zawartej na stronie nr. 6
13. Do not allow children to handle or play with this product. 14. Do not use the Vacuum Blower without its Dust Bag and/or Filter in place. 15. Do not use the Vacuum Blower if it has been dropped, damaged, left outdoors, or immersed in liquid. 16. Do not use the Vacuum Blower to pick up water from containers, i.e., sinks, tubs, barrels, etc. 17. Keep the end of the Hose and its accessories away from your face and body. 18. Avoid accidental falls. Use extra care when cleaning on stairways. 1
Streszczenie treści zawartej na stronie nr. 7
GROUNDING WARNING! Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outle
Streszczenie treści zawartej na stronie nr. 8
DOUBLE INSULATED TOOLS: TOOLS WITH TWO PRONG PLUGS 1. Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Figure C.) 2. Double insulated tools may be used in either of the 120 volt outlets shown in the following illustration. (See Figure B.) 120 VOLT, 120
Streszczenie treści zawartej na stronie nr. 9
7. Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electri- cian before using it. 8. Protect your extension cords from sharp objects, excessive heat, and damp or wet areas. RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120 OR 240 VOLT) NAMEPLATE EXTENSION CORD LENGTH AMPERES (At Full Load) 25 Feet 50 Feet 75 Feet 100 Feet 150 Feet 0 – 2.0 18 18 18 18 16 2.1 – 3.4 18 18 18 16 14
Streszczenie treści zawartej na stronie nr. 10
UNPACKING When unpacking, check to make sure all the parts shown on the Parts List on page 14 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible. ASSEMBLY INSTRUCTIONS CAUTION! Always make sure the Power Switch (2) of the Vacuum Blower is in its “OFF” position and the tool is unplugged from its electrical outlet prior to as- sembling the tool, adding any accessories, or making adjustments to
Streszczenie treści zawartej na stronie nr. 11
3. The Dust Bag (108) is used only for dry vacuuming. To install the Dust Bag, insert its opening over the portion of the Suction Port (13) protruding from within the Tank (15) of the Vacuum Blower. Then, replace the Upper Cover (3) onto the Vacuum Blower. (See Figure F.) 4. The Dry Filter (109) is used only for dry vacuuming. To install the Dry Filter, first make sure that the foam filter is clean, dry, and in place over the filter basket. Then, slide the Dry Filter over the Filter Ba
Streszczenie treści zawartej na stronie nr. 12
6. IMPORTANT: If wet vacuuming, make sure to turn off and unplug the unit frequently during use. Remove the Upper Cover (3) and empty the water in the Tank (15). Once empty, replace the Upper Cover onto the Tank. Plug the unit’s Power Cord (30) back into its electrical outlet, and turn on the unit to resume vacuuming. NOTE: The unit has a built-in float valve which, when the Tank becomes full of water, will automatically turn off the unit. To restart the unit, follow the instructions
Streszczenie treści zawartej na stronie nr. 13
POWER SWITCH FIGURE G (2) SUCTION PORT BLOWER PORT (13) (4) POWER CORD (30) HOSE (110) FLOOR NOZZLE (104) EXTENSION WAND EXTENSION WAND (105) (105) EXTENSION WAND CREVICE TOOL (105) (106) INSPECTION, MAINTENANCE, AND CLEANING 1. WARNING! Make sure the Power Switch (2) of the Vacuum Blower is in its “OFF” position and the tool is unplugged from its electrical outlet before performing any inspection, maintenance, or cleaning procedures. 2. Before each use, inspect the general condition of the V
Streszczenie treści zawartej na stronie nr. 14
PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESS- LY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, A
Streszczenie treści zawartej na stronie nr. 15
ASSEMBLY DIAGRAM 104 110 106 105 108 107 109 NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. SKU 94282 For technical questions, please call 1-800-444-3353 PAGE 15
Streszczenie treści zawartej na stronie nr. 16
LIMITED 90 DAY WARRANTY Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of ninety days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, or to lack of maintenance. We shall in