Streszczenie treści zawartej na stronie nr. 1
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 20
INSTALLATION & OPERATION GUIDE
MSU140
MSU140
INFRARED MAIN SYSTEM UNIT
®
B LENDING H IGH F IDELITY AND A RCHITECTURE
Streszczenie treści zawartej na stronie nr. 2
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 1 I NFR ARED M AIN S Y S TEM U NIT MSU140 Infrared Main System Unit TABLE OF CONTENTS Introduction An infrared (IR) extender system enables you to control Introduction 1 your IR remote controlled A/V equipment from a remote Features and location. This enables you to place your A/V components Benefits 2 out of sight (behind cabinet doors, in the rear of a room, or MSU140 Parts in a different room) and still conveniently operate your Guide 4 equipme
Streszczenie treści zawartej na stronie nr. 3
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 2 I NFRARED M AIN S Y S TEM U NIT Features and Benefits The MSU140 offers a number of improvements over other IR Extender Main System Units: • Universal system—compatible with virtually all brands of A/V equipment and remote controls. • Accommodates one IR sensor or keypad. • Provides four flasher outputs via convenient 3.5mm jacks. • System feedback LED confirms operation. • 3-30V AC/DC status input. Provides system status to con- nected sensor
Streszczenie treści zawartej na stronie nr. 4
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 3 I NFRARED M AIN S Y S TEM U NIT Niles IR Stereo Receiver Flasher 12V DC power supply (supplied with the MSU140 Main System Unit) plugged into an unswitched AC outlet powers the system POWER 12 3 4 3-30V AC/DC +12V DC STATUS FLASHER OUTPUTS IN MSU140 3-30V AC/ DC power supply IR MAIN SYSTEM UNIT INPUT 1 (Not Supplied) plugged into the switched outlet Niles Stock # FG01035 MSU140 Power, IR data, status signal and ground via category 5 wire Fi
Streszczenie treści zawartej na stronie nr. 5
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 4 I NFRARED M AIN S Y S TEM U NIT MSU140 Parts Guide 13 2 4 POWER 12 3 4 3-30V AC/DC +12V DC STATUS FLASHER OUTPUTS IN MSU140 IR MAIN SYSTEM UNIT INPUT 1 5 1. 12V DC Jack – Provides 12 volt DC power to 4. Status/ IR Confirmation LED – This LED MSU via a regulated power supply. performs two functions: (1) it provides a visible indication of system status via a green 2. IR Flasher Outputs – 3.5mm jacks provide out- LED and (2) confirms the recepti
Streszczenie treści zawartej na stronie nr. 6
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 5 I NFRARED M AIN S Y S TEM U NIT Installation Considerations Placement of the MSU140 Place the MSU140 conveniently close to the equipment it IMPORTANT will be controlling. Generally, the unit is placed in a con- Do not place the cealed location because its controls and indicators are only MSU140 on top used during installation. Placement possibilities include: of or directly 1) Table-top (on the shelf behind the equipment) behind a television S
Streszczenie treści zawartej na stronie nr. 7
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 6 I NFRARED M AIN S Y S TEM U NIT Wiring “TECH TIP” From every IR Sensor location you must “home-run” a category 5 cable back to the MSU140. Home run means that an individual cable is connected between each IR Sensor and the MSU140. See Figure 4. Remotely Located IR Sensor Figure 4: Home run the Wire size is sensor cable from the expressed by it’s sensor to the MSU140. AWG (American Wire Gauge) number. The lower the AWG number, SENSORS IN the la
Streszczenie treści zawartej na stronie nr. 8
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 7 I NFRARED M AIN S Y S TEM U NIT Intellipad Wiring When you are placing both a Intellipad and a sensor (or two keypads) in one room you may “daisy-chain” using a single cable. A cable is run between the keypad and the sensor and a single cable is run from the sensor back to the MSU140. To prevent data feedback an IN4003 Blocking Diode is inserted on the data (IR) line between the Intellipad and the sensor. The cathode, or blocking side of the dio
Streszczenie treści zawartej na stronie nr. 9
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 8 I NFRARED M AIN S Y S TEM U NIT Sensor/Keypad Cable TOOLS The MSU140 connects to IR sensors and the Intellipad with REQUIRED category 5 cable, with a maximum cable run of 500'. • 1/8" Standard Flasher Cable Slotted Niles infrared flashers come supplied with a 10 foot 2-con- Screwdriver ductor 22 gauge cable. Should you need to extend it, use a 16 gauge 2-conductor cable (“zip-cord”). Shielding is not • Wire Stripper necessary for a flasher. Fla
Streszczenie treści zawartej na stronie nr. 10
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 9 I NFRARED M AIN S Y S TEM U NIT STEP DESCRIPTION 1. Connect and test the A)Plug the supplied 12vDC power supply into an unswitched power supply. If it tests 120V AC outlet, 50-60 HZ . OK, unplug the connector B) Plug the connector into the socket marked “Power” on the from the power socket MSU140. and proceed. C)If the Power LED does not light, test the unswitched 120 VAC outlet, 50-60 HZ with another appliance. If the outlet tests OK, you have
Streszczenie treści zawartej na stronie nr. 11
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 10 I NFRARED M AIN S Y S TEM U NIT STEP DESCRIPTION 3. Test for shorts and A) Reconnect the power supply. If the Power LED lights and the interference. IR Test LED stays off, unplug the connector from the power socket and proceed to Step 4. The following LED conditions show a fault: •If Power LED is Off there is a short between +12v and GND •If IR Test LED is On or flickers blue there is a short between DATA and GND or interference is present. Be
Streszczenie treści zawartej na stronie nr. 12
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 11 I NFRARED M AIN S Y S TEM U NIT Testing the IR Extender System Test your IR Extender system by following these three principal guidelines: 1. All components can be operated. Test all of your remote controls for all of your equipment. 2. Operation is consistent. A good test is to repeatedly step from Pause to Play with your VCR, CD, DVD, or Tape player remote control. Operation should be identical to standing in front of the component with the
Streszczenie treści zawartej na stronie nr. 13
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 12 I NFRARED M AIN S Y S TEM U NIT Power Status — Introduction To properly wire an Intellipad to the MSU140, refer to Figure 5. By providing 3-30V AC/DC to the status input jack of your MSU140 you can send a status signal to sensors or an IntelliPad without running any additional wiring. Built into the MSU140 is a Niles status signal generator. When the MSU140 sees 3-30V AC/DC at the status jack it broad- casts a status signal over your existing I
Streszczenie treści zawartej na stronie nr. 14
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 13 I NFRARED M AIN S Y S TEM U NIT Power Status — Installation Considerations Proper Power Supply If status is being supplied from a switched outlet you must connect a Niles 12vDC wall adapter (Niles FG01035) into the switched AC power outlet of the preamp/receiver in your system. Any 12vDC power supply with a minimum of 100mA current capacity can be substituted. Extending the Cable If you must extend the cable from the wall adapter to the MSU140
Streszczenie treści zawartej na stronie nr. 15
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 14 I NFRARED M AIN S Y S TEM U NIT POWER 12 3 4 3-30V AC/DC +12V DC STATUS FLASHER OUTPUTS IN MSU140 IR MAIN SYSTEM UNIT INPUT 1 3-30V AC/ DC power supply MSU140 plugged into an unswitched Main System Unit outlet Niles stock#FG01035 IRH610 INPUT 1 INPUT 2 INPUT 3 Expansion Hub OUTPUT TO MSU IRH610 IR EXPANSION HUB POWER STATUS Figure 8 Wiring diagram for INPUT 4 INPUT 5 INPUT 6 Infrared +12V DC Sensors expanding a system using the IRH610 Infrared
Streszczenie treści zawartej na stronie nr. 16
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 15 I NFRARED M AIN S Y S TEM U NIT Troubleshooting Guidelines There are three basic problems which prevent proper oper- ation. In the order of probability the problems are: 1.– Bad Connections or Wiring If the connections or wiring are wrong, loose, shorted or open the system will not operate properly. The symptoms could include: Power LED flickers or is off, IR Test LED is continuously flickering or on without any remote control use, intermitten
Streszczenie treści zawartej na stronie nr. 17
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 16 I NFRARED M AIN S Y S TEM U NIT Solution: To eliminate EMI try the following methods: 1. Move the sensor or the sensor cable away from the EMI source or move the source of the EMI away from the sensor or the cable. 2. Connect the Sensor’s GND terminal to true earth ground (if this isn’t feasible use the main system unit’s GND terminal). 3.– Optical Feedback Loop If you have an IR sensor in the same room as a flasher, and you have some low-l
Streszczenie treści zawartej na stronie nr. 18
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 17 I NFRARED M AIN S Y S TEM U NIT Specifications Contents IR System MSU140 1 Compatible with virtually all brands Screwless Connectors 1 of remotes using carrier frequencies In-line Power Supply 1 between 26 and 105kHz. Self-Adhesive Wiring Requirements Rubber Feet 4 Individual home-runs of category 5 cable from each sensor/keypad. Unit Dimensions 4-3/4” wide x 1-1/4” high x 2” deep Power Requirements 12VDC power supply (included). 17
Streszczenie treści zawartej na stronie nr. 19
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 18 I NFRARED M AIN S Y S TEM U NIT Addendum: Using the MSU140 with the ® IntelliControl automation system 150 OHm Resistor POWER 12 3 4 3-30V AC/DC +12V DC STATUS FLASHER OUTPUTS IN MSU140 IR MAIN SYSTEM UNIT INPUT 1 Using the MSU140 with the IntelliControl Home Theater automation system When connecting an MSU flasher output to an IntelliControl “Home Theater” port, a 150-Ohm resistor must be placed between the data and the ground line of the In
Streszczenie treści zawartej na stronie nr. 20
DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 19 Niles Audio Corporation www.nilesaudio.com ©2005 Niles Audio Corporation. All rights reserved. Niles, the Niles logo, IntelliPad and Blending High Fidelity and Architecture are registered trademarks of Niles Audio Corporation. MicroFlasher is a trademark of Niles 12331 S.W. 130 Street Audio Corporation. Because we strive to improve our products. All other trademarks are the property of their respective owners. Niles reserves the right to chan