Streszczenie treści zawartej na stronie nr. 1
Operations manual
MiniLink® Data 900 and 2400 MHz Series
MicroTek Electronics, Inc.
25691 Atlantic Ocean Drive, Suite B-3; Lake Forest, CA 92630
Technical Support: 888-366-4276
www.microtekelectronics.com
Streszczenie treści zawartej na stronie nr. 2
FCC NOTICE This equipment has been tested and found to comply with the limits of a Class B device, pursuant to PART 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
Streszczenie treści zawartej na stronie nr. 3
INDEX SECTION PAGE # FCC NOTICE ----------------------------------------------------------------- ( i ) INDUSTRY CANADA NOTICE ----------------------------------------- ( i ) QUICK START GUIDE ---------------------------------------------------- 2 PRE-INSTALLATION REMINDER, RETURN POLICY --------- 3 TRANSCEIVER DESCRIPTION---------------------------------------- 4 FRONT VIEW ---------------------------------------------------------------- 4 SIDE VIEW ----------------------
Streszczenie treści zawartej na stronie nr. 4
QUICK START GUIDE MicroTek Electronics, Inc. recommends that all equipment be bench tested before being installed onsite. This test will ensure that all components of your application are functioning properly. DATA TRANSCEIVER SET-UP 1. Remove each Transceiver from the box and attach its omni-directional dipole antenna. 2. If the device in use operates at a different Baud Rate than the factory setting of 4800, the radio must be changed to the desired Baud rate using the Software. See
Streszczenie treści zawartej na stronie nr. 5
PRE-INSTALLATION REMINDERS The information on the Quick Start Guide is intended for ease of use and application, the following reminders will help to ensure your satisfaction with MicroTek products and service. 1. Read through this manual before bench testing and installation 2. Make sure that you set the Data radios to the Baud Rate that will match your Control and/or Camera 3. Perform a bench test incorporating all components of the application 4. Install your MiniLink Data 900 or 2400
Streszczenie treści zawartej na stronie nr. 6
MINILINK 900 AND 2400 MHZ DATA TRANSCEIVERS TRANSCEIVER DESCRIPTION The MiniLink Data 900/2400 transceivers are either point-to-point or point-to-multi-point units. Software is provided to configure each radio to match the configurations of your camera and controlling device. If the Baud Rate is not set correctly, the control functions will not transmit and the camera will not move accordingly. MiniLink Data 900/2400 transceivers are designed for line of sight operation and will transm
Streszczenie treści zawartej na stronie nr. 7
TRANSCEIVER OPERATION HOW TO SET UP EACH TRANSCEIVER 1. LOCATION Each Transceiver is designed to be placed on a flat surface for stability. The transceivers are not weatherproof and should be placed indoors or in an environmental enclosure if used outdoors or in a harsh environment. Included in each of MicroTek’s environmental enclosure is a piece of double-sided tape that can be used to mount the transceiver inside the housing. 2. POWER The MiniLink Data unit is powered by a 6-20 V
Streszczenie treści zawartej na stronie nr. 8
TRANSCEIVER OPERATION (Continued) 1. Set-up Tab This screen is used to set the PC Serial Port to interface with the MiniLink Data 900 or 2400 MHz Transceiver. The parameters in this tab must match the PC Serial Port Parameters for communication to be established. 2. Com Test Tab This screen is used to test the MiniLink Data transceiver and monitor communications once the two transceivers are both set to match the parameters of your system. Running a Com Test: (See Notes and instructio
Streszczenie treści zawartej na stronie nr. 9
TRANSCEIVER OPERATION (Continued) • Avoid clicking on “Restore Module Defaults” as Multiple Default-Resets could result in a software lockout, requiring a factory reset of the Transceiver unit(s). If you are experiencing software difficulty, try refreshing by clicking on a separate file tab such as “Set-up” and re-click “Configuration” then try the command again. NOTE: All transceivers communicating with one another in a system must be configured identically. If the parameters are change
Streszczenie treści zawartej na stronie nr. 10
TRANSCEIVER SPECIFICATIONS RF SECTION Power Output 140 mW (900 MHz), 50 mW (2.4 GHz) Transmitting Frequency 900 to 928 MHz 2.4000 to 2.4835 GHz Modulation Frequency Hopping Spread Spectrum Channel Capacity 7 hop sequences share 25 frequencies Over Air Baud Rate Up to 19200 bps FCC ID OUR9XSTREAM (900 MHz) OUR-24XSTREAM (2.4 GHz) Industry Canada 4214A-9XSTREAM (900 MHz) 4214A 12008 (2.4 GHz) Europe ETSI, CE (2.
Streszczenie treści zawartej na stronie nr. 11
TROUBLESHOOTING PROBLEM SUGGESTION No wireless control should be the only problem that would be related to the MiniLink Data transceivers. For all other problems, refer to the operations manual for other equipment that is being used. Try the following suggestions to obtain wireless control: 1. Verify mode selection switches are in the UP position for RS-422/485 or in the DOWN position for RS-232. 2. Both transceivers must match parameters. Camera does not respond 3. Transceivers’ param
Streszczenie treści zawartej na stronie nr. 12
WARRANTY INFORMATION MICROTEK LIMITED WARRANTY MicroTek Electronics extends the following LIMITED WARRANTY to the original owner/purchaser of this product: 1) If, within two years after date of initial sale, this product, or any part or portion thereof, shall prove upon examination by MICROTEK, to be defective in material or workmanship, MICROTEK will repair or replace such part or portion at MICROTEK’s option. The warranty period on the repaired or replaced part or port