Streszczenie treści zawartej na stronie nr. 1
INSTALLATION INSTRUCTIONS
Rotary Flat Mount
Model: RFM
AUSTRALIA, NEW ZEALAND, OCEANIA
EUROPE
NORTH AMERICA (DISTRIBUTOR)
3130 East Miraloma Avenue
Swallow House,
P.O. Box 295
Anaheim, CA 92806 USA
Shilton Industrial Estate,
Mordialloc Victoria 3195
USA and Canada –
Shilton, Coventry, England CV79JY
Australia
Phone: 800-368-9700
Phone: +44 (0) 2476 614700
Phone: 039586 6330
Fax: 800-832-4888
Fax: +44 (0) 2476 614710
www.premiermounts.com.au
Other Locations – Phone: (001)-714-632-7100; Fax: (00
Streszczenie treści zawartej na stronie nr. 2
RFM Table of Contents Contact Premier Mounts 2 Warning Statements 3 Parts List 4 Installation Tools 4 Thread Depth Indicator 7 Mount Installation 8 Concrete Mounting 9 Universal Mounting Bracket Installation 9 Display Orientation 11 Technical Specifications 11 Warranty 12 Warning Statements PRIOR TO THE INSTALLATIO
Streszczenie treści zawartej na stronie nr. 3
RFM Parts List This mount is shipped with all installation hardware and components. Make sure that none of these parts are missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop and contact Premier Mounts (800) 368-9700. Universal Mounting Brackets (Qty 2) Rotating Universal Bracket Bar (Qty 1) 5/16” x 3” Lag Bolts - wooden studs 5/16” Flat Washers M6 Knurl Knob Griplate™ (Qty 8) only (Qty 6) (Qty 6) (Qty 1) Installation Tools Phillips
Streszczenie treści zawartej na stronie nr. 4
RFM (Qty 8) (Qty 8) M4 x 16 M6 x 20 (Qty 8) M4 x 25 (Qty 8) M6 x 30 M5 x 12 (Qty 8) M6 x 45 (Qty 8) (Qty 8) M5 x 16 M8 x 20 (Qty 8) (Qty 8) M5 x 20 (Qty 8) (Qty 8) M8 x 25 M5 x 25 (Qty 8) M5 x 50 M8 x 30 (Qty 8) (Qty 8) M6 x 16 M8 x 35 (Qty 8) M8 x 45 (Qty 8) M8 x 70 (Qty 4) Page 4 Installation Instructions
Streszczenie treści zawartej na stronie nr. 5
RFM The nylon spacers may be stacked to achieve proper spacing. 9/16" Nylon spacers 1/4" Nylon spacers (large) (Qty 8) (Qty 8) 1/2" Nylon spacers Nylon sleeves (large) (Qty 8) (Qty 12) 5/16" Flat washers (metal) (Qty 8) 1" Nylon Spacers (Qty 8) 1/4" Nylon spacers (small) (Qty 8) Installation Instructions Page 5
Streszczenie treści zawartej na stronie nr. 6
RFM Thread Depth Indicator 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the fl at panel to make sure the inserts measure the same full depth and mark it (Figure 1). 2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). 3. If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw. 4. The screw length must not bypass the marking. Select
Streszczenie treści zawartej na stronie nr. 7
RFM Mount Installation Step 1 Step 2 Step 3 Determine where the mount lo- Once the stud has been located, use a pencil Using a 1/4” drill bit, drill the upper mount- cation will be. Use a stud finder to mark the spot. ing hole where the mark was made. to locate the nearest wall stud. For ease of installation, it is recommended that two people perform the installation. One person should hold the mount while the other person installs the lag bolt and washer. Making sure that the mount is leve
Streszczenie treści zawartej na stronie nr. 8
RFM Concrete Mounting Concrete anchors must be used for concrete installation. They can be purchased at your local hardware store. The mounting surface must be a minimum 6” thick. 1. Begin by placing the mount into position against the wall, keeping it level. 2. Mark off four holes to be used for securing the mount. 3. Next, drill holes using a masonry bit for your anchors (recommended masonry bit). 4. Insert a commercially available concrete anchor into each hole (recommended 3/8” wedge a
Streszczenie treści zawartej na stronie nr. 9
RFM 6. Lower the universal bracket bar with attached display into the cradle (as shown to the left). Nylon Sleeve After loosening the tension bolts, be sure that the nose piece is held together tightly before rotating. Knurl Knob Mounting Point/M6 x 12mm Security Head and M6 Lock Washer Mounting Point. 7. Insert an M6 Knurl Knob/M6 x 12mm Security Head and M6 Lock Washer into the knurl knob/ security screw mounting point and tighten. To access the knurl knob/security screw location
Streszczenie treści zawartej na stronie nr. 10
RFM Display Orientation The RFM will allow the user to adjust the display a full 360°. BEFORE ROTATING THE RFM, MAKE SURE THAT THE M6 KNURL KNOB IS SECURELY FASTENED TO THE RFM. ALSO, PLEASE MAKE SURE YOU ALLOW ENOUGH CABLE AND WIRE CLEARANCE FOR FULL ROTATION. M6 Knurl Knob 1. To adjust the RFM, rotate the display either clockwise or counter-clockwise. 2. Tighten the two Phillips head locking screws (see Step 8, Page 10). Technical Specifications All measurements are in inches (mm).
Streszczenie treści zawartej na stronie nr. 11
RFM Warranty PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of the original owner of this product. The limited warranty is valid only for the original purchaser of the product. What Premier Mounts Will Do At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is defective. If