Streszczenie treści zawartej na stronie nr. 1
CSX400 AND CSX400-DC
USER’S GUIDE
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
Notice Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES
Streszczenie treści zawartej na stronie nr. 4
Notice VCCI Notice This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Cabletron Systems, Inc. Program License Agreement IMPORTANT: Before utilizing this product, carefully read this License Agreement. This document is an agreement bet
Streszczenie treści zawartej na stronie nr. 5
Notice Exclusion of Warranty and Disclaimer of Liability 1. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Cabletron makes no warranty, expressed or implied, concerning the Program (including its documentation and media). CABLETRON DISCLAIMS ALL WARRANTIES, OTHER THAN THOSE SUPPLIED TO YOU BY CABLETRON IN WRITING, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
Streszczenie treści zawartej na stronie nr. 6
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC 91/263/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/33
Streszczenie treści zawartej na stronie nr. 7
Contents CHAPTER 1 INTRODUCTION Related Documentation .................................................................................. 1 How to Use This Guide ................................................................................... 1 Document Conventions................................................................................... 3 Getting Help .................................................................................................... 4 CHAPTER 2 ABOUT THE CSX4
Streszczenie treści zawartej na stronie nr. 8
Contents CHAPTER 3 ISDN LINE ORDERING AND CONFIGURATION Arranging ISDN Service................................................................................23 Telephone Switch Support............................................................................24 ISDN BRI Line Configuration ........................................................................24 ISDN BRI Configurations........................................................................25 SPIDs, Directory Numbers
Streszczenie treści zawartej na stronie nr. 9
Contents CSX-COMP/ENCR Installation .....................................................................62 Installing the CSX400....................................................................................63 Tabletop and Shelf Installations .............................................................63 CSX400 and CSX400-DC Rackmount Installation .................................64 Connecting the CSX400 to the Power Source..............................................68 Connecting
Streszczenie treści zawartej na stronie nr. 10
Contents CHAPTER 8 GENERAL CONFIGURATION USING LOCAL MANAGEMENT Chapter Organization..................................................................................125 Local Management Overview......................................................................126 Management Agent ..............................................................................126 Local vs. Remote Management............................................................126 Local Management Screen Elements....
Streszczenie treści zawartej na stronie nr. 11
Contents Bridge Setup Screen...................................................................................149 Bridge Setup Screen Fields..................................................................149 Selecting a Spanning Tree Protocol .....................................................150 Selecting the Bridge Port Administrative Status ...................................150 Selecting the Bridge Port Pair Administrative Status............................151 Router Setup Screen.
Streszczenie treści zawartej na stronie nr. 12
Contents CHAPTER 10 TROUBLESHOOTING Troubleshooting CSX400 Hardware ...........................................................208 Power (PWR) LED is OFF....................................................................208 Processor (CPU) LED is OFF...............................................................208 Processor (CPU) LED is RED ..............................................................208 Troubleshooting the LAN ..........................................................
Streszczenie treści zawartej na stronie nr. 13
Contents APPENDIX B WPIM CABLE SPECIFICATIONS WPIM-T1.....................................................................................................223 WPIM-SY ....................................................................................................225 EIA-449.................................................................................................226 V.35 ......................................................................................................227 EIA
Streszczenie treści zawartej na stronie nr. 14
Contents xii CSX400 and CSX400-DC User’s Guide
Streszczenie treści zawartej na stronie nr. 15
1 Introduction Welcome to the Cabletron Systems CSX400 and CSX400-DC User’s Guide. This guide provides basic configuration information, hardware specifications and troubleshooting tips for the CSX400 and CSX400-DC. This guide also provides background information about 10BASE-T Ethernet Local Area Networks (LANs) and guidelines for routing and bridging over Wide Area Networks (WANs). The CSX400 and CSX400-DC have identical features and functions with the exception
Streszczenie treści zawartej na stronie nr. 16
Introduction Chapter 3, ISDN Line Ordering and Configuration, provides the information you need to order ISDN service from the telephone company. Chapter 4, Planning for CSX400 ISDN Configuration, describes the router configuration process. Chapter 5, Ethernet Cabling Requirements, describes the basic cabling requirements for an Ethernet Local Area Network (LAN). Chapter 6, Installation, provides detailed installation instructions for
Streszczenie treści zawartej na stronie nr. 17
Introduction Document Conventions The following conventions are used throughout this guide: Note symbol. Calls the reader’s attention to any item of information that may be of NOTE special importance. Tip symbol. Conveys helpful hints concerning procedures or actions. TIP Caution symbol. Contains information essential to avoid damage to the equipment. ! CAUTION Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical h
Streszczenie treści zawartej na stronie nr. 18
Introduction Getting Help If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the Cabletron Systems Global Call Center: Phone (603) 332-9400 Internet mail support@ctron.com FTP ctron.com (134.141.197.25) Login anonymous Password your email address BBS (603) 335-3358 Modem setting 8N1: 8 data bits, No parity, 1 stop bit For additional information about Cabletron Systems or our products, visit our World Wi
Streszczenie treści zawartej na stronie nr. 19
2 About the CSX400 The CSX400 (Figure 1) is an access device that provides Ethernet Local Area Network (LAN) connectivity via two Ethernet Port Interface Modules (EPIMs), and offers high-speed Wide Area Network (WAN) access to remote sites via two WAN Port Interface Modules (WPIMs). The CSX400 supports IEEE 802.1d transparent bridging, IP and IPX routing, ISDN, Dynamic Host Configuration Protocol (DHCP), Network Address Translation (NAT) routing, and Inverse Multiplexing (IMUX) between Ethe
Streszczenie treści zawartej na stronie nr. 20
About the CSX400 • The WPIM-Sync provides a synchronous serial connection of up to 2.048 Mbps to external communications equipment (e.g., a multiplexer or CSU/DSU). The WPIM-Sync uses a subminiature 26-pin connector that supports the electrical signal interfaces listed below. Appendix B, provides complete part number and cable pinout information for the following electrical signal interfaces: • EIA-RS449 • V.35 • EIA-RS232D • X.21 • EIA-RS530 • EIA-530A • RS530 ALT A • RS530A ALT A • The WPI