AT-8600 Series Installation & Safety Guide AT-8624T/2M AT-8624PoE AT-8648T/2SP Download the complete document set from www.alliedtelesis.com/support/software
Streszczenie treści zawartej na stronie nr. 3
2 AT-8600 Series Switch AT-8600 Installation & Safety Guide Document Number C613-000083 REV H © 2006-2011 Allied Telesis Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis Inc. Allied Telesis Inc. reserves the right to change specifications and other information in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis Inc. be l
Streszczenie treści zawartej na stronie nr. 4
Installation & Safety Guide 3 Table of Contents Models Covered by this Guide ...................................................................................... 4 Package Contents ............................................................................................................. 4 Selecting a Site ................................................................................................................... 5 Installing the Switch ................................................
Streszczenie treści zawartej na stronie nr. 5
4 AT-8600 Series Switch Models Covered by this Guide This document includes information about the following switches: ■ AT-8624T/2M 24-port 10BASE-T/100BASE-TX ■ AT-8624PoE 24-port 10BASE-T/100BASE-TX ■ AT-8648T/2SP 48-port 10BASE-T/100BASE-TX You can download updates to this document from www.alliedtelesis.com/ support. Package Contents The following items are shipped with each switch. Contact your authorised distributor or reseller if any are damaged or missing. ■ One AC power cord ■ One pow
Streszczenie treści zawartej na stronie nr. 6
Installation & Safety Guide 5 Selecting a Site Before you install the switch, review the following considerations about its location. ■ The switch requires an ambient temperature range of 0 º C to 40º C (32º F to 104º F). ■ There should be adequate airflow around the switch and its vents. ■ The site should be dust-free and without moisture. ■ Humidity can be from 5% to 80% non-condensing. ■ You need a reliable and earthed (grounded) power supply source, preferably dedicated and filtered. ■ Ca
Streszczenie treści zawartej na stronie nr. 7
6 AT-8600 Series Switch Installing the Switch Ports on the switch are suitable only for connections within buildings (intra- building) and with cables unexposed to the outside. Before you begin ■ Read the safety information. For your well-being and that of the equipment, read the safety information in this document. You can also download this document from the Documentation and Tools CD-ROM or from www.alliedtelesis.com/support/ software. ■ Verify the package contents if you have not already d
Streszczenie treści zawartej na stronie nr. 8
Installation & Safety Guide 7 Procedure 1. If you have any optional expansion modules, install them first. The AT-8600 Series switches support the AT-A45/xx, AT-A46, AT-A47, and AT-A65 expansion modules. Install them by following the instructions in the relevant guide: � AT-A65 Expansion Module Installation and Safety Guide for the AT-A65 module only. � AT-A45/xx Series, AT-A46, and AT-A47 Expansion Modules Installation Guide for the other expansion modules. These instructions ship with ind
Streszczenie treści zawartej na stronie nr. 9
8 AT-8600 Series Switch . release lever hinge AT-8600_sfp_shaded Slide the transceiver into the SFP socket, and firmly press it until it engages. To remove it, first release it by gently pulling the release lever, and then pull it out of the socket. Never force a transceiver into or out of a socket. When an SFP is installed into one of the two SFP ports, that SFP port takes precedence over its corresponding 10/100/1000T port. When the SFP is removed, the 10/100/1000T port is once again act
Streszczenie treści zawartej na stronie nr. 10
Installation & Safety Guide 9 Figure 2: AT-8624PoE front and rear panel with AC power inlet 13 5 7 9 11 13 15 17 19 21 23 AT-8624POE Layer 3 Fast Ethernet Switch 100 LINK ACT 10 LINK ACT FULL DUP HALF DUP COL PD ON PD ERR MAX CURRENT MODE RS-232 STATUS 1 3 5 7 9 11131517192123 TERMINAL PORT FAULT 25 26 MASTER RPS PWR 2 4 6 8 10 12 14 16 18 20 22 24 2 4 6 8 10 12 14 16 18 20 22 24 Figure 3: AT-8648T/2SP front and rear panel with AC power inlet LINK 49R MODE CLASS 1 LASER PRODUCT AT-8648T/2SP Laye
Streszczenie treści zawartej na stronie nr. 11
10 AT-8600 Series Switch Connecting the Switch Some configuration is necessary to enable the switch’s advanced switching capabilities. This is achieved via the Command Line Interface (CLI). On the AT-8624T/2M, you can also use the Graphical User Interface (GUI). Using the CLI to configure a switch 1. Connect a terminal or PC to the terminal port (ASYN0). Using the supplied RS-232 DB9 serial straight-through cable, connect your terminal or PC to the RS-232 port: � For the AT-8624T/2M and AT-86
Streszczenie treści zawartej na stronie nr. 12
Installation & Safety Guide 11 5. Configure online help. Before using online help, you must configure the help file by using the command: set help=.hlp Help files have an HLP extension. To see a list of help files loaded on your switch, use the command: show files=*.hlp 6. Configure the switch. Refer to the Software Reference for more information about configuring the software. Alternatively, if you do not know the command syntax, use any of the following to help you: � To display
Streszczenie treści zawartej na stronie nr. 13
12 AT-8600 Series Switch 2. Connect the PC to the switch. Use an Ethernet cable to connect an Ethernet card on the PC to any one of the switch ports. You can browse to the router through any VLAN, as long as you give that VLAN an IP address. These instructions assume you are using vlan1. All switch ports belong to vlan1 by default. 3. Access the switch’s command line interface. Access the CLI from the PC, as described in the previous section, “Using the CLI to configure a switch” on page 10.
Streszczenie treści zawartej na stronie nr. 14
Installation & Safety Guide 13 Checking LEDs The following tables outline how the switch and expansion modules report faults and operational activities. Expansion modules are optional and can be purchased separately. System LEDs LED State Description FAULT Off Switch operation is normal. Red The switch or management software is malfunctioning. 1 flash A switch fan has failed. 3 flashes The main PSU has failed and the RPS is now providing power. 4 flashes The RPS Monitor is set to ON, and th
Streszczenie treści zawartej na stronie nr. 15
14 AT-8600 Series Switch Link and Mode LEDs for the AT-8624T/2M switch LED State Description LINK Off There is no link between the port and the end-node. Green A valid link has been established between the port and the end-node. Mode - COL Off No data collisions are occurring on the port. Flashing Green Data collisions are occurring on the port. Mode - 100 Off The port is operating at 10 Mbps. Green The port is operating at 100 Mbps. Mode - FULL Off The port is operating in half-duplex mode.
Streszczenie treści zawartej na stronie nr. 16
Installation & Safety Guide 15 Link and Mode LEDs for the AT-8624PoE switch LED State Description L/A Status Off There is no link between the port (Top LED) and the end-node. Green The port is operating at 100 Mbps. Flashing Green There is activity on the port. It is transmitting and/or receiving data at 100 Mbps. Red The port is operating at 10 Mbps. Flashing Red There is activity on the port. It is transmitting and/or receiving data at 10 Mbps. Mode LEDs Off Either DC Mode or PoE Mode. (
Streszczenie treści zawartej na stronie nr. 17
16 AT-8600 Series Switch Link and Mode LEDs for the AT-8648T/2SP switch LED State Description LINK Off There is no link between the port and the end-node. Green A valid link has been established between the port and the end- node. Mode - COL Off No data collisions are occurring on the port. Flashing Green Data collisions are occurring on the port. Mode - SPD Off The port is operating at 10 Mbps. Green The port is operating at 100 Mbps. Mode - FDX Off The port is operating in half-duplex m
Streszczenie treści zawartej na stronie nr. 18
Installation & Safety Guide 17 SFP and 10/100/1000Base-T LEDs for the AT-8648T/2SP switch LED State Description LINK Off There is no link between the port and the end-node. Green A valid link has been established between the port and the end- node. Mode - COL Off No data collisions are occurring on the port. Flashing Green Data collisions are occurring on the port. Mode - SPD Off The port is operating at 10/100 Mbps. Green The port is operating at 1000 Mbps. Mode - FDX Off The port is op
Streszczenie treści zawartej na stronie nr. 19
18 AT-8600 Series Switch Obtaining Documentation and Resources The complete document set for the AT-8600 Series switches includes: ■ This Installation & Safety Guide, which also provides safety and statutory information for the AT-8600 Series switch and its expansion options. ■ The AT-8600 Series Hardware Reference, which provides detailed information on the switch unit and its hardware features. ■ The AT-8600 Series Software Reference, which provides detailed information on configuring the
Streszczenie treści zawartej na stronie nr. 20
Installation & Safety Guide 19 Standards Where applicable, the products in this document meet the following standards: Category Approval Agency and Requirement UL60950-1 CAN/CSA-C22.2 No. 60950-1-03 EN60950-1 EN60825-1 Electromagnetic Compliance FCC CFR47 Part 15 Class A EN55022 Class A EN61000-3-2 EN61000-3-3 VCCI Class A AS/NZS CISPR22 Class A Immunity EN55024 U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a C