Streszczenie treści zawartej na stronie nr. 1
General-Purpose AC Servo
J2-Super Series
General-Purpose Interface
MODEL
MR-J2S- A
SERVO AMPLIFIER
INSTRUCTION MANUAL
H
Streszczenie treści zawartej na stronie nr. 2
Safety Instructions (Always read these instructions before using the equipment.) Do not attempt to install, operate, maintain or inspect the servo amplifier and servo motor until you have read through this Instruction Manual, Installation guide, Servo motor Instruction Manual and appended documents carefully and can use the equipment correctly. Do not use the servo amplifier and servo motor until you have a full knowledge of the equipment, safety information and instructions. In this Instructi
Streszczenie treści zawartej na stronie nr. 3
1. To prevent electric shock, note the following: WARNING Before wiring or inspection, switch power off and wait for more than 15 minutes. Then, confirm the voltage is safe with voltage tester. Otherwise, you may get an electric shock. Connect the servo amplifier and servo motor to ground. Any person who is involved in wiring and inspection should be fully competent to do the work. Do not attempt to wire the servo amplifier and servo motor until they have been installed. Otherwise, you may get
Streszczenie treści zawartej na stronie nr. 4
4. Additional instructions The following instructions should also be fully noted. Incorrect handling may cause a fault, injury, electric shock, etc. (1) Transportation and installation CAUTION Transport the products correctly according to their masses. Stacking in excess of the specified number of products is not allowed. Do not carry the servo motor by the cables, shaft or encoder. Do not hold the front cover to transport the servo amplifier. The servo amplifier may drop. Install the servo amp
Streszczenie treści zawartej na stronie nr. 5
CAUTION Securely attach the servo motor to the machine. If attach insecurely, the servo motor may come off during operation. The servo motor with reduction gear must be installed in the specified direction to prevent oil leakage. Take safety measures, e.g. provide covers, to prevent accidental access to the rotating parts of the servo motor during operation. Never hit the servo motor or shaft, especially when coupling the servo motor to the machine. The encoder may become faulty. Do not subject
Streszczenie treści zawartej na stronie nr. 6
(4) Usage CAUTION Provide an external emergency stop circuit to ensure that operation can be stopped and power switched off immediately. Any person who is involved in disassembly and repair should be fully competent to do the work. Before resetting an alarm, make sure that the run signal of the servo amplifier is off to prevent an accident. A sudden restart is made if an alarm is reset with the run signal on. Do not modify the equipment. Use a noise filter, etc. to minimize the influence of ele
Streszczenie treści zawartej na stronie nr. 7
(6) Maintenance, inspection and parts replacement CAUTION With age, the electrolytic capacitor of the servo amplifier will deteriorate. To prevent a secondary accident due to a fault, it is recommended to replace the electrolytic capacitor every 10 years when used in general environment. Please consult our sales representative. (7) General instruction To illustrate details, the equipment in the diagrams of this Specifications and Instruction Manual may have been drawn without covers and safety
Streszczenie treści zawartej na stronie nr. 8
COMPLIANCE WITH EC DIRECTIVES 1. WHAT ARE EC DIRECTIVES? The EC directives were issued to standardize the regulations of the EU countries and ensure smooth distribution of safety-guaranteed products. In the EU countries, the machinery directive (effective in January, 1995), EMC directive (effective in January, 1996) and low voltage directive (effective in January, 1997) of the EC directives require that products to be sold should meet their fundamental safety requirements and carry the CE marks
Streszczenie treści zawartej na stronie nr. 9
(4) Power supply (a) Operate the servo amplifier 7kW or less to meet the requirements of the overvoltage category II set forth in IEC60664-1. For this purpose, a reinforced insulating transformer conforming to the IEC or EN standard should be used in the power input section. Since the 11kW or more servo amplifier can be used under the conditions of the overvoltage category III set forth in IE60664-1, a reinforced insulating transformer is not required in the power input section. (b) When supplyi
Streszczenie treści zawartej na stronie nr. 10
(7) Auxiliary equipment and options (a) The no-fuse breaker and magnetic contactor used should be the EN or IEC standard-compliant products of the models described in Section 13.2.2. (b) The sizes of the cables described in Section 13.2.1 meet the following requirements. To meet the other requirements, follow Table 5 and Appendix C in EN60204-1. Ambient temperature: 40 (104) [ ( )] Sheath: PVC (polyvinyl chloride) Installed on wall surface or open table tray (c) Use the EMC filter for noise redu
Streszczenie treści zawartej na stronie nr. 11
CONFORMANCE WITH UL/C-UL STANDARD (1) Servo amplifiers and servo motors used Use the servo amplifiers and servo motors which comply with the standard model. Servo amplifier :MR-J2S-10A to MR-J2S-22KA MR-J2S-10A1 to MR-J2S-40A1 Servo motor :HC-KFS HC-MFS HC-SFS HC-RFS HC-UFS HA-LFS HC-LFS (2) Installation 3 Install a fan of 100CFM (2.8m /min) air flow 4 in (10.16 cm) above the servo amplifier or provide cooling of at least equivalent capability. (3) Short circuit rating This servo a
Streszczenie treści zawartej na stronie nr. 12
<> This Instruction Manual and the MELSERVO Servo Motor Instruction Manual are required if you use the General-Purpose AC servo MR-J2S-A for the first time. Always purchase them and use the MR- J2S-A safely. Relevant manuals Manual name Manual No. MELSERVO-J2-Super Series To Use the AC Servo Safely IB(NA)0300010 MELSERVO Servo Motor Instruction Manual SH(NA)3181 EMC Installation Guidelines IB(NA)67310 A - 11
Streszczenie treści zawartej na stronie nr. 13
MEMO A - 12
Streszczenie treści zawartej na stronie nr. 14
CONTENTS 1. FUNCTIONS AND CONFIGURATION 1- 1 to 1-24 1.1 Introduction.............................................................................................................................................. 1- 1 1.2 Function block diagram .......................................................................................................................... 1- 2 1.3 Servo amplifier standard specifications ....................................................................................
Streszczenie treści zawartej na stronie nr. 15
3.8.2 Connection diagram......................................................................................................................... 3-50 3.8.3 I/O terminals .................................................................................................................................... 3-52 3.9 Servo motor with electromagnetic brake ............................................................................................. 3-54 3.10 Grounding ..................................
Streszczenie treści zawartej na stronie nr. 16
6.8.3 Positioning operation....................................................................................................................... 6-15 6.8.4 Motor-less operation........................................................................................................................ 6-16 7. GENERAL GAIN ADJUSTMENT 7- 1 to 7-12 7.1 Different adjustment methods ............................................................................................................... 7- 1 7.1.1
Streszczenie treści zawartej na stronie nr. 17
11.2 Connectors............................................................................................................................................11- 8 12. CHARACTERISTICS 12- 1 to 12- 8 12.1 Overload protection characteristics...................................................................................................12- 1 12.2 Power supply equipment capacity and generated loss ....................................................................12- 2 12.3 Dynamic brake characteri
Streszczenie treści zawartej na stronie nr. 18
14.9 Initialization........................................................................................................................................14-10 14.10 Communication procedure example ...............................................................................................14-10 14.11 Command and data No. list.............................................................................................................14-11 14.11.1 Read commands.................................
Streszczenie treści zawartej na stronie nr. 19
Optional Servo Motor Instruction Manual CONTENTS The rough table of contents of the optional MELSERVO Servo Motor Instruction Manual is introduced here for your reference. Note that the contents of the Servo Motor Instruction Manual are not included in the Servo Amplifier Instruction Manual. 1. INTRODUCTION 2. INSTALLATION 3. CONNECTORS USED FOR SERVO MOTOR WIRING 4. INSPECTION 5. SPECIFICATIONS 6. CHARACTERISTICS 7. OUTLINE DIMENSION DRAWINGS 8. CALCULATION METHODS FOR DESIGNING 6
Streszczenie treści zawartej na stronie nr. 20
1. FUNCTIONS AND CONFIGURATION 1. FUNCTIONS AND CONFIGURATION 1.1 Introduction The Mitsubishi MELSERVO-J2-Super series general-purpose AC servo is based on the MELSERVO-J2 series and has further higher performance and higher functions. It has position control, speed control and torque control modes. Further, it can perform operation with the control modes changed, e.g. position/speed control, speed/torque control and torque/position control. Hence, it is applicable to a wide range of fields, not