Streszczenie treści zawartej na stronie nr. 1
™
CrossPoint 450 Plus Series
MAV Plus series
Large Scale Matrix Switchers
68-521-03 Rev. B
11 09
Streszczenie treści zawartej na stronie nr. 2
Precautions Safety Instructions • English Warning Power sources • This equipment should be operated only from the power source indicated on the product. This This symbol is intended to alert the user of important operating and maintenance equipment is intended to be used with a main power system with a grounded (neutral) conductor. The (servicing) instructions in the literature provided with the equipment. third (grounding) pin is a safety feature, do not attempt to bypass or disable it. Th
Streszczenie treści zawartej na stronie nr. 3
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is
Streszczenie treści zawartej na stronie nr. 4
Streszczenie treści zawartej na stronie nr. 5
Table of Contents Chapter One • Introduction .......................................................................................................1-1 About this Manual......................................................................................................................1-2 About the Matrix Switchers.................................................................................................1-2 Features..........................................................................
Streszczenie treści zawartej na stronie nr. 6
Table of Contents, cont’d Setting.RGB.delay. (sy stems.with.wideband.BMEs) .............................................................3-27 Example.6:.Setting.the.RGB.delay. for.an.output.............................................................3-27 Using.presets.............................................................................................................................3-29 Example.7:.Saving.a.preset.........................................................................
Streszczenie treści zawartej na stronie nr. 7
Switcher-Initiated Messages................................................................................................4-6 Switcher Error Responses......................................................................................................4-7 Using the Command/Response Tables............................................................................4-7 Command/response.table.for.SIS.commands.........................................................................4-8 Sy mbol.def
Streszczenie treści zawartej na stronie nr. 8
Table of Contents, cont’d Chapter Six • HTML Operation..................................................................................................6-1 Downloading the Startup Page..........................................................................................6-2 Status Tab.........................................................................................................................................6-3 Sy stem.Status.page...................................................
Streszczenie treści zawartej na stronie nr. 9
Appendix A • Ethernet Connection..................................................................................... A-1 Ethernet Link................................................................................................................................ A-2 Ethernet.connection................................................................................................................. A-2 Default.IP.address...........................................................................
Streszczenie treści zawartej na stronie nr. 10
Table of Contents, cont’d vi CrossPoint 450 Plus and MAV Plus Switchers • Table of Contents
Streszczenie treści zawartej na stronie nr. 11
CrossPoint 450 Plus and MAV Plus Switchers Chapter One 1 Introduction About.this.Manual About.the.Matrix.Switchers Features
Streszczenie treści zawartej na stronie nr. 12
Introduction About this Manual This manual contains installation, configuration, and operating information for the ™ Extron family of full-function, very large CrossPoint 450 Plus ultra-wideband and MAV Plus 3248 through 6464 video and audio matrix switchers. About the Matrix Switchers Matrix switchers distribute any input to any combination of outputs. The matrix switchers can route multiple input/output configurations simultaneously. The Extron very large CrossPoint 450 Plus and MAV Plus m
Streszczenie treści zawartej na stronie nr. 13
Some BMEs are equipped with integrated QuickSwitch-Front Panel Controllers ™ (QS-FPC ): • The CrossPoint 450 Plus video BME is available with or without a QS-FPC. • The MAV Plus video BME is always equipped with a QS-FPC. • The CrossPoint 450 Plus sync BME is not available with a QS-FPC. • The MAV Plus audio BME (stereo or mono) is not available with a QS-FPC. • BMEs without a QS-FPC are equipped with blank front panels. A wideband (RGBHV or RGBS) video matrix switcher system requires a
Streszczenie treści zawartej na stronie nr. 14
Introduction, cont’d A low resolution video matrix switcher system requires a MAV Plus video BME for each video plane (three BMEs for component video, two BMEs for S-video, or one BME for composite video). To add audio to the system requires a MAV Plus stereo or mono audio BME. N Multiple QS-FPCs are unnecessary and potentially confusing. To avoid confusion, Extron recommends that you lock the redundant QS-FPCs. See "Setting the front panel locks (Executive modes
Streszczenie treści zawartej na stronie nr. 15
Features Video (video BMEs) — All switchers input and output video on BNC connectors. • CrossPoint 450 Plus wideband video — These switcher BMEs input and output wideband RGBHV or RGBS video. They can also switch RGsB, RsGsBs, component/HDTV, S-video, or composite video. • MAV Plus low resolution video — These switcher BMEs input and output NTSC 3.58, NTSC 4.43, PAL, or SECAM video or HDTV video inputs. Depending on the video format of the switcher system, these switchers can dist
Streszczenie treści zawartej na stronie nr. 16
Introduction, cont’d ™ Digital Sync Validation Processing (DSVP ) (CrossPoint 450 Plus sync BMEs) — In critical environments or unmanned remote locations, it may be vital to know that sources are active and switching. The DSVP feature confirms that input sources are active by scanning all sync inputs for active signals. DSVP provides instantaneous frequency feedback for composite sync or separate horizontal and vertical sync signals via the switcher’s serial ports or LAN port. The freque
Streszczenie treści zawartej na stronie nr. 17
Switching flexibility — Provides individually buffered, independent matrix switched outputs with audio follow and audio breakaway for systems with audio BMEs. • Tie any input to any or all outputs • Quick multiple tie — Multiple inputs can be switched to multiple outputs simultaneously. This allows all displays (outputs) to change from source to source at the same time. • Audio follow — Audio can be switched with its corresponding video input via front panel control or under Eth
Streszczenie treści zawartej na stronie nr. 18
Introduction, cont’d Labeling — The included Extron Button Label Generator software lets you create labels to place in the front panel I/O buttons, with names, alphanumeric characters, or color bitmaps for easy and intuitive input and output selection. ™ ™ Alternatively, labels can be made with any Brother P-Touch or comparable labeler. Global memory presets — 64 global memory presets are a time-saving feature that lets you set up and store input/output configurations in advance. You can
Streszczenie treści zawartej na stronie nr. 19
CrossPoint 450 Plus and MAV Plus Switchers Chapter Two 2 Installation Setup.and.Installation.Checklist Mounting.the.Switcher Rear.Panel.Cabling.and.Features Front.Panel.Configuration.Port
Streszczenie treści zawartej na stronie nr. 20
Installation Setup and Installation Checklist Get ready c Familiarize yourself with the CrossPoint 450 Plus and MAV Plus matrix switcher BMEs. c Obtain IP setting information for the matrix switcher from the local network administrator. Read appendix A, “Ethernet Connection”. Perform physical installation c If desired, create button labels (page 5-25) and replace them (page B-14). c If desired, install the switcher BMEs in a rack (below). c Set the BME addresses. c Connect the BME COMM interc