Streszczenie treści zawartej na stronie nr. 1
Crestron CLW-SW1/4RF,
CLW-SWS1/4RF, CLW-SLVS1RF
infiNET™ Switches
Operations Guide
Streszczenie treści zawartej na stronie nr. 2
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ® ® Windows and Windows XP are registered trademarks of Microsoft Corporation in the United States and other countries. ©2005 Crestron Electro
Streszczenie treści zawartej na stronie nr. 3
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Contents infiNET™ Switches: CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF 1 Introduction ...............................................................................................................................1 Features and Functions................................................................................................1 Specifications ............................................................................................
Streszczenie treści zawartej na stronie nr. 4
Streszczenie treści zawartej na stronie nr. 5
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches infiNET™ Switches: CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Introduction Features and Functions The CLW-SW1RF (-SW1RF) one-button switch and CLW-SW4RF (-SW4RF) four-button switch are stand-alone wall box switches that can also act as wireless ® infiNET™ devices that report to a Crestron control processor via a Crestron infiNET wireless gateway. infiNET Switches Functional Summary • Two-way infiNET switches ⇒ 2.4 GHz infiNET mes
Streszczenie treści zawartej na stronie nr. 6
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET Gateway and, if more devices are needed, more C2N-MNETGW gateways ® may be added to a Cresnet network. Crestron infiNET switches operate on the 2.4 GHz “ISM band” (2400 MHz to 2483.6 MHz) at 10 mW. The output power of these devices allow RF signals to travel approximately 150 feet indoors and 250 feet outdoors (subject to site-specific conditions) without the use of repeaters or other infiNET devices. The range is depende
Streszczenie treści zawartej na stronie nr. 7
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches CLW-SW1/4RF, CLW-SWS1/4RF, & CLW-SLVS1RF Specifications (continued) SPECIFICATION DETAILS Operating Ranges¹ Typical Distance 150 ft Indoors (without repeater) Typical Distance Outdoors 250 ft, subject to site-specific conditions Default MNET ID -SW1RF/-SW4RF: 01/01 -SWS1RF/-SWS4RF: 01/01 Switch Type Single-Pole, Single-Throw Load Type Incandescent, Tungsten-Halogen, Fluorescent / High Intensity Discharge (HID), Electro
Streszczenie treści zawartej na stronie nr. 8
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF 5. VA ratings are for input power to the transformer. If you do not know the input power requirement of the transformer, use the bulb’s wattage rating to determine proper rating. NOTE: Crestron software and any files on the website are for Authorized Crestron dealers and Crestron Authorized Independent Programmers (CAIP) only. New users may be required to register to obtain access to certain areas of the site (including the FTP s
Streszczenie treści zawartej na stronie nr. 9
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Physical View of CLW-SW1RF/-SWS1RF (Clockwise from Top; Top, Side, and Front) 1.75 in (4.45 cm) 2.38 in 1.88 in (6.03 cm) (4.77 cm) 3.81 in (9.68 cm) 3.28 in 2.70 in (8.32 cm) 4.13 in (6.86 cm) (10.48 cm) RUN SET OFF 1.50 in (3.81 cm) The -SW4RF and -SWS4RF have a light emitting diode (LED) with adjustable brightness (via Crestron programming software), four pushbuttons, and a three- position mode selection switch as shown in the f
Streszczenie treści zawartej na stronie nr. 10
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Physical View of CLW-SW4RF/-SWS4RF (Clockwise from Top; Top, Side, and Front) 1.75 in (4.45 cm) 2.38 in 1.88 in (6.03 cm) (4.77 cm) 3.81 in (9.68 cm) 3.28 in 2.70 in (8.32 cm) 4.13 in (6.86 cm) (10.48 cm) RUN SET OFF 1.50 in (3.81 cm) The -SLVS1RF is similar in appearance to the -SW1RF and -SWS1RF but does not have the three-position mode selection switch. The brightness of the LED on the -SLVS1RF is not programmable. CLW-SLVS1R
Streszczenie treści zawartej na stronie nr. 11
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches Physical View of CLW-SLVS1RF (Clockwise from Top; Top, Side, and Front) 1.88 in 1.75 in (4.77 cm) (4.45 cm) 3.81 in (9.68 cm) 3.28 in 2.70 in (8.32 cm) 4.13 in (6.86 cm) (10.48 cm) 1.50 in (3.81 cm) The -SW1RF, -SW4RF, -SWS1RF, -SWS4RF, and -SLVS1RF mount in a standard wallbox and are covered using a decorative faceplate (not included). All line voltage connections are made at the rear of the switch. Industry Compliance These u
Streszczenie treści zawartej na stronie nr. 12
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Industry Canada Statement The term "IC" before the certification/registration number only signifies that the Industry Canada technical specifications were met. IC: 5683A-CWD1011 Acquiring the Switch on the infiNET Network Before an infiNET device can be used on an infiNET network, it must first be acquired to a C2N-MNETGW gateway that is connected to a Cresnet network. NOTE: The -SW1RF, -SW4RF, -SWS1RF, and -SWS4RF can also wor
Streszczenie treści zawartej na stronie nr. 13
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches mode. The device is acquired when the LED stops blinking and lights at the LOW setting. After being acquired, the device will exit the Acquire mode. The switch will be acquired on the C2N-MNETGW with an MNET ID value of 01. 3. Take the C2N-MNETGW out of the Acquire mode once all devices have been acquired. Refer to the latest revision of the C2N-MNETGW Operations Guide (Doc. 6137), which is available from the Crestron website.
Streszczenie treści zawartej na stronie nr. 14
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF RUN When the switch is in the “RUN” position, it is operating in the RUN mode. This is the normal operating mode of the switch. The RUN mode is used to turn the load on and off. If a delay time is set, the switch will turn off the load after the set delay time. For information on setting a delay time, refer to “SET” below. Refer to the following table for a list of available functions when the switch is operating in the RUN mode.
Streszczenie treści zawartej na stronie nr. 15
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches After setting the preset value(s), return the mode selection switch to the “RUN” position. -SLVS1RF The -SLVS1RF has one rocker button. The -SLVS1RF does not have a mode selection switch. It will emulate the RUN mode of the -SWS1RF (even if connected to a -SWS4RF) unless the mode selection switch of the master is set to “OFF”. Restoring Default Settings To restore the switch’s default settings (delay time equal to zero seconds)
Streszczenie treści zawartej na stronie nr. 16
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF Identity Code Just like every device on a Cresnet system requires a unique identity code (NET ID), every device and user interface on the infiNET network requires a unique identity code (MNET ID). These codes are two-digit hexadecimal numbers from 03 to 20. The MNET ID of each unit must match an ID code specified in the SIMPL Windows program. Refer to “Setting the MNET ID in Device Settings” on page 26 for details of the SIMPL Wi
Streszczenie treści zawartej na stronie nr. 17
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches The infiNET switch and dimmers have already been acquired as described in the acquiring procedure described on page 8. The devices have been assigned the default MNET ID 01 as shown in the Network Device Tree window below. Network Device Tree 1. With the Network Device Tree open, select Tools | SMW Program Tree, or click . SMW Program Tree-Click to Select Program 2. Click the text “Click here to open program…” to select the
Streszczenie treści zawartej na stronie nr. 18
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF After selecting a file, SIMPL Windows will initialize and the SMW Program Tree will be displayed. SMW Program Tree Devices with NET IDs or MNET IDs that have been identified by the SMW Program Tree are marked with a icon. Devices with NET IDs or MNET IDs that could not be identified are marked with a icon. NOTE: Descriptions such as “BR Dimmer”, “LR Dimmer”, and “kitchen switch” were created by editing each devices symbol n
Streszczenie treści zawartej na stronie nr. 19
Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF infiNET™ Switches 4. In the SMW Program Tree, right-click on the top level of the tree and select Link with Network Control. Link with Network Control A window will be displayed with instructions for linking the SMW Program Tree to the Network Device Tree. Link Instruction Window 5. Click OK. The cursor will change to a target selector ( ). 6. Click on the Network Device tree that is to be linked to the SMW Program Tree, A message will be
Streszczenie treści zawartej na stronie nr. 20
infiNET™ Switches Crestron CLW-SW1/4RF, -SWS1/4RF, -SLVS1RF The “Setup Lighting” window will open and display a list of unidentified lighting devices. Setup Lighting Window The listed devices can be sorted in ascending or descending order by clicking on the column headers. The order can also be adjusted by selecting a device and clicking the or buttons. This can be used when setting up devices in the order they will be encountered. For example, when identifying devices in a home, an