Streszczenie treści zawartej na stronie nr. 1
53-1002085-02
®
15 December, 2011
Brocade VDX 6720
QuickStart Guide
Supporting the VDX 6720-24 and VDX 6720-60
53-1002085-02
*53-1002085-02*
Streszczenie treści zawartej na stronie nr. 2
Copyright © 2010 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCFM, DCX, Fabric OS, FastIron, IronView, NetIron, SAN Health, ServerIron, TurboIron and Wingspan are registered trademarks, and Brocade Assurance, Brocade NET Health, Brocade One, Extraordinary Networks, MyBrocade, and VCS are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may b
Streszczenie treści zawartej na stronie nr. 3
Overview This Quick Start guide is intended as an overview to help experienced installers unpack, install, and configure the Brocade VDX 6720 quickly. For more detailed installation and configuration instructions, see the Brocade Network OS Administrator’s Guide and the Brocade Network OS Command Reference Manual. NOTE Throughout this document, the Brocade VDX 6720 is referred to as the switch. Items included with the Brocade VDX 6720 The following items are included with the standard shipment
Streszczenie treści zawartej na stronie nr. 4
. TABLE 1 Power Supply Specifications Specification Value Maximum output 250 watts, 4 amps, 12 VDC - VDX 6720-24 500 watts, 7 amps, 12 VDC - VDX 6720-60 Maximum AC power consumption 146.2 W - VDX 6720-24 360 W - VDX 6720-60 System DC power consumption (excluding power supply Idle: 182.4 W and fan FRUs) Maximum: 306 W Input system power (including power supply and fan Idle: 206 W FRUs) Maximum: 306 W Input voltage 85-264 VAC Input line frequency 47-63 Hz BTU rating 1044.11 BTU/hr Inrush curren
Streszczenie treści zawartej na stronie nr. 5
Recommendations for cable management The minimum bend radius for a 50 micron cable is 2 inches under full tensile load and 1.2 inches with no tensile load. Cables can be organized and managed in a variety of ways, for example, using cable channels on the sides of the cabinet or patch panels to minimize cable management. Following is a list of recommendations: NOTE You should not use tie wraps with optical cables because they are easily overtightened and can damage the optic fibers. Velcro-li
Streszczenie treści zawartej na stronie nr. 6
ATTENTION Do not connect the switch to the network until the IP address is correctly set. For instructions on how to set the IP address, see “Setting the switch IP address.” Rack installation for a Brocade VDX 6720 Follow the installation instructions shipped with the appropriate rack mount kit: • To install the switch into a fixed-rail rack, refer to the Fixed Rack Mount Kit (24”-32”) Installation Procedure or the Fixed Rack Mount Kit Installation Procedure. • To install the switch into Telco
Streszczenie treści zawartej na stronie nr. 7
1. Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the workstation or terminal device. If the serial port on the workstation or terminal device is RJ45 instead of RS-232, remove the adapter on the end of the serial cable and insert the exposed RJ45 connector into the RJ45 serial port on the workstation. 2. Open a terminal emulator application (such as HyperTerminal on a PC, or TERM, TIP, or Kermit in a UNIX environment), and configure the application
Streszczenie treści zawartej na stronie nr. 8
Setting the switch IP address You can configure the Brocade VDX 6720 with a static IP address, or you can use a DHCP (Dynamic Host Configuration Protocol) server to set the IP address of the switch. DHCP is enabled by default. The Brocade VDX 6720 supports both IPv4 and IPv6 format addresses. For information about setting static IP addresses and stateless IPv6 addresses, please see the Brocade Network OS Administrator’s Guide. Using DHCP to set the IP address When using DHCP, the Brocade VDX
Streszczenie treści zawartej na stronie nr. 9
Another parameters that can be changed if necessary is the VCS ID. This identifies the VCS fabric of which the switch can be a part. By default, the VCS of every VDX 6720 is 1. Change the VCS ID if you need to create a new, separate VCS fabric. If you need to change the VCS ID, use the vcs-id x parameter, where x is the new VCS ID number. vcs rbridgeid 1 vcsid 2 enable 4. Enter the copy running-config startup-config command to apply the currently running configuration, including any changes
Streszczenie treści zawartej na stronie nr. 10
! 1. Remove any protector plugs from the transceivers and the ports. 2. Making sure that the bail (wire handle) is in the unlocked position, place the transceiver in the correctly oriented position on the port, as shown in Figure 1. 3. Slide the SFP+ into the port until you feel it click into place; then close the bail. FIGURE 1 Installing an SFP+ in the upper row of port slots 4. If this is not a direct-connect unit, remove the protective caps from the cable end and position the cable so that
Streszczenie treści zawartej na stronie nr. 11
! FIGURE 2 Inserting a cable into an SFP+ Connecting to Ethernet or fast Ethernet hubs For copper connections to Ethernet hubs, a 10/100Base-TX or 1000Base-T switch, or another Brocade device, a crossover cable is required. If the hub is equipped with an uplink port, it will require a straight-through cable instead of a crossover cable. NOTE The 802.3ab standard (automatic MDI or MDIX detection) calls for automatic negotiation of the connection between two 1000Base-T ports. Therefore, a cross
Streszczenie treści zawartej na stronie nr. 12
12 of 12 Brocade VDX 6720 QuickStart Guide Publication Number: 53-1002085-02