Streszczenie treści zawartej na stronie nr. 1
AUGUST 2002
SW485A
SW487A-R2
6 x 4 Electronic SCSI Switch
CUSTOMER
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
SUPPORT
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
INFORMATION Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: info@blackbox.com
Streszczenie treści zawartej na stronie nr. 2
FCC/IC RFI STATEMENTS, EU DECLARATION OF CONFORMITY FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO-FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in
Streszczenie treści zawartej na stronie nr. 3
6 x 4 ELECTRONIC SCSI SWITCH NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas.
Streszczenie treści zawartej na stronie nr. 4
NOM STATEMENT 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena ext
Streszczenie treści zawartej na stronie nr. 5
6 x 4 ELECTRONIC SCSI SWITCH TRADEMARKS USED IN THIS MANUAL BLACK BOX and the logo are registered trademarks of Black Box Corporation. AppleTalk, EtherTalk, and Macintosh are registered trademarks of Apple Computer, Inc. DEC and LAT are trademarks of Compaq Corporation. Microsoft, Windows, and Windows NT are registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. IPX is a trademark, and NetWare is a registered trademark, of Novell Incorporated. U
Streszczenie treści zawartej na stronie nr. 6
TABLE OF CONTENTS Contents Chapter Page 1. Specifications ..........................................................................................................7 2. Introduction ..........................................................................................................10 2.1 About the SCSI Switch ..................................................................................10 2.2 Features .....................................................................................
Streszczenie treści zawartej na stronie nr. 7
6 x 4 ELECTRONIC SCSI SWITCH Chapter Page 5. Configuration and Operation (continued) 5.8 Graphical User Interface (GUI) ................................................................32 5.9 Connecting Multiple SCSI Switches ..........................................................33 5.10 Rackmount Installation ..............................................................................33 5.10.1 Installation Procedure......................................................................33 5.1
Streszczenie treści zawartej na stronie nr. 8
CHAPTER 1: Specifications 1. Specifications SCSI Interface Maximum Port Switching Delay: 3 ns Maximum Signal Skew: 2 ns Internal Terminator Power: 1 amp Rear-Panel Connectors: 68-pin high-density SCSI-1, SCSI-2, & SCSI-3, SPI-2 compatible (also Ultra160 SCSI [“Ultra3 SCSI”] for SW487A-R2); asynchronous and synchronous compatible; conforms to ANSI X3.131 and X3T9.2 Single-Ended (SE) SCSI (SW487A-R2 Only) Maximum Data Rate (8-bit Narrow): 20 MBps Maximum Data Rate (16-bit Wide): 40 MBps Maximum Po
Streszczenie treści zawartej na stronie nr. 9
6 x 4 ELECTRONIC SCSI SWITCH Low-Voltage Differential (LVD) SCSI (SW487A-R2 Only) Maximum Data Rate (8-bit Narrow): 40 MBps for Ultra2 SCSI (narrow transfers aren’t officially supported in the Ultra160 SCSI standard) Maximum Data Rate (16-bit Wide): 160 MBps Maximum Port Cable Length: 25 meters (82 ft.) Internal Terminator Impedance: 105 ohms Terminator Disconnect Capacitance: 3 pF Active Internal Bus Termination Serial Interface Baud Rate: 9600 or 19,200 bps Data Format: No parity, 8 bits, 1 st
Streszczenie treści zawartej na stronie nr. 10
CHAPTER 1: Specifications Physical Temperature: 32 to 149°F (0 to 65°C) Humidity: Up to 90% noncondensing Power: 105 to 240 VAC ± 10% (25 watts) Size: 3.5"H x 16.8"W x 12"D (8.9 x 42.7 x 30.5 cm) Weight: 5 lb. (2.3 kg) 9
Streszczenie treści zawartej na stronie nr. 11
6 x 4 ELECTRONIC SCSI SWITCH 2. Introduction 2.1 About the SCSI Switch The 6 x 4 Electronic SCSI Switch is a high-performance electronic crosspoint switch for use with the SCSI (Small Computer System Interface) bus. It enables groups of four and six independent SCSI buses to be selected and electrically connected in any combination via internal electronic switching circuits. The 6 x 4 Electronic SCSI Switch eliminates the need to swap and reconfigure SCSI cables and bus terminators when alterna
Streszczenie treści zawartej na stronie nr. 12
CHAPTER 2: Introduction 2.2.1 LCD PANEL The 6 x 4 Electronic SCSI Switch features an easy-to-use, menu-driven LCD panel with soft-touch MENU, ENTER, and directional keys. The LCD is lighted, which allows for easy viewing and operation. 2.2.2 FRONT-PANEL CONTROLS • Set and configure SCSI ports. • Set termination. • Set switch number. • View power-supply status. • View internal temperature. • Set internal-temperature alarm. • Set serial-port configuration. • Display SCSI-bus busy status. • Display
Streszczenie treści zawartej na stronie nr. 13
6 x 4 ELECTRONIC SCSI SWITCH 2.3.2 GENERAL HARDWARE DESCRIPTION The 6 x 4 Electronic SCSI Switch’s rear panel identifies each of the independent SCSI ports. SCSI ports A, B, C, and D have two daisychained connectors per port, and SCSI ports 1, 2, 3, 4, 5, and 6 have single connectors for installation of SCSI devices. You can install the SCSI Switch at any point on the SCSI bus. Each port has internal termination that can be turned on or off from the LCD panel. External “termination power” (TERMP
Streszczenie treści zawartej na stronie nr. 14
CHAPTER 2: Introduction You can selectively enable or disable any internal terminator to meet system configurations and requirements. SCSI Switch Ports Figure 2-1. Electronic SCSI Switch block diagram. 13
Streszczenie treści zawartej na stronie nr. 15
6 x 4 ELECTRONIC SCSI SWITCH SCSI Switch (SW487A-R2) Figure 2-2. Typical switch installation. 14
Streszczenie treści zawartej na stronie nr. 16
CHAPTER 3: Installation 3. Installation 3.1 What’s Included • (1) 6 x 4 Electronic SCSI Switch • (1) AC power cord • (1) 10-ft. (3-m) DB9-male-to-DB9-female RS-232 adapter • (1) DB9-male-to-DB25-female RS-232 adapter • (1) SCSI Switch control software CD-ROM • Rackmount handles and screws • Bottom feet • This users’ manual If anything is missing or damaged, call Black Box at 724-746-5500. 3.2 AC Line Voltage You can connect the SCSI Switch to any AC input voltage between 105 and 240 volts. Unles
Streszczenie treści zawartej na stronie nr. 17
6 x 4 ELECTRONIC SCSI SWITCH 3.5 SCSI Interface Cabling Both versions of the 6 x 4 Electronic SCSI Switch are supplied with 68-pin shielded high-density SCSI-2 connectors. Single-ended devices can have cable lengths up to 20 ft. (6 m). Differential or low-voltage differential (LVD) devices can be connected with up to 82 ft. (25 m) of cable. Connect the host adapter or peripheral to the rear-panel connector using the proper SCSI cable. Section 6.1 describes standard SCSI-cable interface requireme
Streszczenie treści zawartej na stronie nr. 18
CHAPTER 4: Operator Controls and Indicators 4. Operator Controls and Indicators 4.1 AC Power Switch The AC power switch is located on the Switch’s rear panel. Move it to the “|” position to turn on the SCSI Switch. NOTE Always turn on the SCSI Switch before powering SCSI devices and computers. This will ensure that devices are found when the system boots up. 4.2 LCD Display, Keypad, and Indicators 4.2.1 LCD DISPLAY The LCD display shows the selection parameters available. SET PORTS > SET TERMINA
Streszczenie treści zawartej na stronie nr. 19
6 x 4 ELECTRONIC SCSI SWITCH 4.2.2 KEYPAD Use the keypad to select menu and setup parameters for the SCSI Switch. • MENU: Returns to the SCSI Switch setup and configuration menu. • ENTER: Selects the highlighted setup parameter. • UP, DOWN, RIGHT, LEFT Arrows: Scrolls the cursor to enable menu selection. 4.2.3 INDICATORS The indicators provide SCSI Switch status information. • POWER: Indicates that the SCSI Switch is powered. • BUSY: Indicates that there is SCSI activity on one or more SCSI port
Streszczenie treści zawartej na stronie nr. 20
CHAPTER 4: Operator Controls and Indicators 4.3 LCD Display Control Menus SET PORTS SET PORTS 123456 A|*|||||| B| |*||||| C|||*|||| D|||||*| | SET TERMINATION SET TERMINATION | A |B |C * | D | | 1 |2 |3 * | 4 | | 5 * | 6 ||| DISPLAY PORTS DISPLAY PORTS | A 1| A 2 | A 3| A 4 | A 5| A 6 | | B 1| B 2 | B 3| B 4 | B 5| B 6 | | C 1| C 2 | C 3| C 4 | C 5| C 6 | | D 1| D 2 | D 3| D 4 | D 5| D 6 | 19