Streszczenie treści zawartej na stronie nr. 1
DS Series Manual
DATA SWITCH
DS72 ETHERNET Host Module
BayTech Manual Publication
Revision May 2008
Streszczenie treści zawartej na stronie nr. 2
DS72 Host Module Copyright 2007 by Bay Technical Associates, Inc. BayTech, is a registered trademarks of Bay Technical Associates, Inc. Windows 2000®, Windows XP® are products and registered trademark of Microsoft Corporation. Tera Term is a product and registered trademark of Vector, Inc. 2
Streszczenie treści zawartej na stronie nr. 3
DS72 Host Module ABOUT THIS OWNER’S MANUAL ........................................................................................................5 Connection Description.......................................................................................................................5 EIA-232 SERIAL CONNECTION.....................................................................................................5 10/100 BASE-T NETWORK PORT CONNECTION ....................................
Streszczenie treści zawartej na stronie nr. 4
DS72 Host Module Status ...................................................................................................................................................30 Unit Reset.............................................................................................................................................31 Troubleshooting:...................................................................................................................................31 Functional Solutio
Streszczenie treści zawartej na stronie nr. 5
DS72 Host Module ABOUT THIS OWNER’S MANUAL This document provides information required for installing and operating your Bay Tech equipment. It should allow the user to connect, power up, and access an applications menu where peripheral equipment can be controlled. We recommend reading this manual carefully, while placing special emphasis on correct cabling and configuration. If you have any problems with your installation, please contact a BayTech Applications Engineer at 228-563-7334, or
Streszczenie treści zawartej na stronie nr. 6
DS72 Host Module from a DB-25 connector to an RJ-45 connector is also available from Bay Tech, upon request (Bay Tech Part No. 25FRJ45PC-4). The 8-pin crossed modular cable is configured for these adapters. NOTE: Use rollover (RJ08X007) RJ-45 cables when using modular connectors to interface the DS-Series to another BayTech product with modular connectors, such as the RPC Remote Power Control Unit. 10/100 BASE-T NETWORK PORT CONNECTION Using a straight 10/100 Base-T cable, connect the
Streszczenie treści zawartej na stronie nr. 7
DS72 Host Module to the power source. Do not attempt to modify any portion or component of a DS72 module unless specifically directed by BayTech Technical Support. BayTech must perform any internal changes. CAUTION: High-voltage surges and spikes can damage this equipment. To protect from such power surges and spikes, this unit must have a good earth ground. A grounding screw connection is located near the power switch on the back of the unit. CAUTION: Before removing or replacing any
Streszczenie treści zawartej na stronie nr. 8
DS72 Host Module 22. Select the ‘Gateway Address’ option and type the assigned Gateway address and press ‘Enter’. 23. Press ‘Enter’ until you are asked to ‘Accept Changes’. Type ‘Y’ to accept changes. 24. Press ‘Enter’ until you get the Network Access Menu, (Figure 1). 25. Select ‘Unit reset’ to update the external connections. Once the reset is completed (1 minute) connect the Baytech device to your network using an Ethernet cable. At this point you have setup enough basic configuratio
Streszczenie treści zawartej na stronie nr. 9
DS72 Host Module Figure 2 DS72 Data Switch Series - Telnet Host Module Revision F.3.21.4 Kernel K.1.01H Core C.1.00N Hardware H.2.01 Module 2 Status..........................1 Current status of DS72 module Serial Port Configuration.......2 Change port config, 9600, 8, 1, none Port Device Name................3 Change the name of the module port Attention Character.............4 (;;;;;) get Main Menu Disconnect Timeguard............5 Delay to
Streszczenie treści zawartej na stronie nr. 10
DS72 Host Module Figure 4 User Management Menu To change user password, enter number of user. To add/delete user, select appropriate menu choice. Enter request, CR to exit menus. A)...Add user 1)...admin Enter Request :a Network Port Configuration Figure 5 Network Configuration IP Address: 0.0.0.0 Subnet Mask: 0.0.0.0 Gateway: 0.0.0.0 Ethernet Address: 00.C0.48.06.57.4C Connection Inactivity Timeout (mins): Disabled Carriage R
Streszczenie treści zawartej na stronie nr. 11
DS72 Host Module Cabling RJ-45 Cables and Adapters DS72 EIA-232 RJ-45 Pin/Signal Definition Pin EIA 232 Signal Description Signal Direction 1 DTR Out Handshake, Line Driver Inactive State = High: +12V when power is applied. Used as a handshake line to enable/disable the receiving of characters. 2 GND Signal Ground 3 RTS Out Handshake, Line Driver Inactive State = High: +12 V when power is applied. Not used to enable/disable. 4 TX Out Transmit Data Out 5 RX In Receive Data In
Streszczenie treści zawartej na stronie nr. 12
DS72 Host Module Adapters 9FRJ45PC-4 RJ08X007 Figures 1 and 2 provide visual representation of an RJ-45 receptacle and plug. 12
Streszczenie treści zawartej na stronie nr. 13
DS72 Host Module Detailed Operation and Configuration Main Screen DS72 - Ethernet & RS232 Host module for DS SERIES chassis Once connected, you will see the menu screen as shown below. This shows the operation of the unit. Depending on which Network Host module you have, the below screens may vary. The screens below are show with the DS72 module. When prompted at the unit’s startup menu select “C” followed by a . This will take you to the Configuration menu. Module: 2 Attent
Streszczenie treści zawartej na stronie nr. 14
DS72 Host Module Configuration Menu The configuration menu allows the admin user to choose a module to access and edit its configuration. The following pages define each line of the configuration menu. Configuration DS72 ................1 Host Module DS74 Module# 3 ................2 I/O Serial port DS-RPC ................3 Assign users, outlet name, E/D confirmation/status menu, unit id, alarm set. Exit............................X,CR Enter th
Streszczenie treści zawartej na stronie nr. 15
DS72 Host Module Installed Modules :03,05 Attention Character is .........; Disconnect Time Guard is........Disabled Port ID Echo is.................Disabled Unit ID is......................DS72 Network Setup : Ethernet Address................00.C0.48.06.57.4C IP Address......................0.0.0.0 Subnet Mask.....................0.0.0.0 Gateway.........................0.0.0.0 Inactivity Timeout (mins).......Disabled Break Length (msecs)............350
Streszczenie treści zawartej na stronie nr. 16
DS72 Host Module +----+--------+----------------+------+------+------+------+----+----+----+----+ |Port| Device | Device | Baud | Word | Stop |Parity|Xon/ Xoff|LineDrive| | | Type | Name | Rate | Size | Bits | |Xmit|Recv|DTR |RTS | +----+--------+----------------+------+------+------+------+----+----+----+----+ | 1 |RS-232 |EIA-232 | 9600 | 8 | 1 |None |Off |Off |Low |Low | +----+--------+----------------+------+------+------+------+----+----+---
Streszczenie treści zawartej na stronie nr. 17
DS72 Host Module 1 For 1 2 For 1-1/2 3 For 2 Parity Parity is a simple form of error checking used in serial communication. For even and odd parity, the serial port will set the parity bit (the last bit after the data bits) to a value to ensure that the transmission has an even or odd number of logic high bits. For example, if the data was 011, then for even parity, the parity bit would be 0 to keep the number of logic high bits even. If the parity was odd, then the parity bit w
Streszczenie treści zawartej na stronie nr. 18
DS72 Host Module DTR Line Driver Inactive State is: Low High ? (Y/N, CR for no change): Serial Port Device Name Select a port and type the new name: Enter Port Device Name (Max. 16 characters): or press ENTER for no change .....: Attention Character Pressing the Attention Character 5 consecutive times will access the network main menu. The Default is a semi-colon (;). Select this option to change the attention character. The DS displays the following: Attention Character is....
Streszczenie treści zawartej na stronie nr. 19
DS72 Host Module BAYTECH For further information check: http://www.baytech.net/ DS71MD4 <= Device name Port echo. or 02,1 <= Module and Port Number echo. Select option 1, to disable the echo. The Default setting is Disabled. Select option 2 to echo the module and port number. (i.e. 3,2) Select option 3 to echo the device name. (Device A) Port ID Echo is...................Disabled Disable Port ID Echo..............1 Use Module, Port Number...........2 Use Devi
Streszczenie treści zawartej na stronie nr. 20
DS72 Host Module Login setup Toggle option by entering number, CR to exit. Network access: 1)...Prompt for user name: disabled 2)...Prompt for password : disabled Serial Port Access: 3)...Prompt for user name: disabled 4)...Prompt for password : disabled CAUTION: Before you enable the password for either Serial Port or Network access, verify the admin password is known, or you could create a lockout condition. If the password lockout condition occurs, you will need to res