IntraCore 39240/480 Layer 2+ Gigabit Ethernet Switch User’s Manual Asante 47709 Fremont Blvd Fremont, CA 94538 USA SALES 408-435-8388 TECHNICAL SUPPORT 408-435-8388: Worldwide www.asante.com/support support@asante.com Copyright © 2008 Asante. All rights reserved. No part of this document, or any associated artwork, product design, or design concept may be copied or reproduced in whole or in part by any means without the express written consent of As
Streszczenie treści zawartej na stronie nr. 3
Table of Contents IntraCore 39240/480.............................................................................................................................2 Chapter 1: Introduction…………………………………………………………………………………………………………...7 1.1 Features...................................................................................................................................................................7 1.2 System Defaults.................................................................
Streszczenie treści zawartej na stronie nr. 4
3.2 Connecting to a PC................................................................................................................................................22 3.3 Username and Password................................................................................................................................22 3.5 Restoring Factory Defaults.....................................................................................................................................23 Chap
Streszczenie treści zawartej na stronie nr. 5
5.5 Spanning Tree Algorithm .......................................................................................................................................40 5.5.1 Spanning Tree Parameters..........................................................................................................................40 5.5.2 Rapid Spanning Tree Protocol (RSTP) ........................................................................................................41 5.5.3 Configuring spannin
Streszczenie treści zawartej na stronie nr. 6
Chapter 9: Configuring the Switch Using the GUI ........................................................................................................61 9.1 Main Configuration Menu .......................................................................................................................................62 9.2 System ...................................................................................................................................................................6
Streszczenie treści zawartej na stronie nr. 7
Chapter 1: Introduction The IntraCore IC39240/480 24-port Layer 2+ Managed Gigabit Switch is a high-performance network switch used to reduce network congestion and application response times. The 24-port/48-port IntraCore IC39240/480 multi-protocol switch supports Layer 2+ and Gigabit Ethernet switching. The switch has 24/48 10/100/1000BaseT ports with Auto- Uplink and has 4 combination ports used for sharing with SFP mini GBICs. Gigabit fiber technology is used to connect two switches to
Streszczenie treści zawartej na stronie nr. 8
1.2 System Defaults The system defaults are the configuration parameters set in the factory. Use command ‘Clear config’ to restore the defaults. The following table lists some of the basic system defaults. Function Parameter Default Console Port Connection Baud Rate Auto Data bits 8 Stop bits 1 Parity none Local Console Timeout 300 seconds Authentication login Username “admin” Password “Asante” Enable Privileged Exec from Normal Exec Username “admin” Level Password “Asante” RAD
Streszczenie treści zawartej na stronie nr. 9
Flow Control Disabled Port Capability 1000BASE-T – 10 Mbps half duplex 10 Mbps full duplex 100 Mbps half duplex 100 Mbps full duplex 1000 Mbps full duplex Full-duplex flow control disabled Symmetric flow control disabled 1000BASE-SX/LX/LH – 1000 Mbps full duplex Full-duplex flow control disabled Symmetric flow control disabled Rate Limiting Input and Output Limits Disabled Port Trucking LACP (all ports) Disabled Broadcast Storm Protection Status Enabled (all ports) Broadca
Streszczenie treści zawartej na stronie nr. 10
IP Settings IP Address 192.168.0.1 Subnet Mask 255.255.255.0 Default Gateway 0.0.0.0 DHCP Client: Disabled ARP Enabled Multicast Filtering IGMP Snooping Disabled System Log Remote logging Disabled Memory-log Enabled Flash-log Enabled SNTP Clock Synchronization Disabled 10 Asante IntraCore IC39240/480 User’s Manual
Streszczenie treści zawartej na stronie nr. 11
1.3 Package Contents The following items are included in the switch’s package: • Switch • AC power cord • RS232 straight-through serial cable for management console port • Rack mount brackets with screws • IntraCore IC39240/480 CD-ROM Contact your dealer immediately if any of these items is missing. 1.4 Front and Back Panel Descriptions The following section describes the front and back panels of the IntraCore IC39240/480 Series switches. The front panel of the IntraCore IC39240/4
Streszczenie treści zawartej na stronie nr. 12
39480 Front Panel Ethernet ports Mini GBIC ports 39480 Rear Panel 12 Asante IntraCore IC39240/480 User’s Manual
Streszczenie treści zawartej na stronie nr. 13
1.4.1 LEDs The IC39240/480 front panel LED display allows you to monitor the status of the switch. The IC39240/480 has one power LED indicator. There are also LED indicators for each of the ports. Refer to the following table for LED information. LED Color Description Power Green Power is on. Off Power is off, or main power has failed. 1000MBps Amber A valid 1000 Mbps link has been established on the port. Green A valid 10/100 Mbps link has been established on the port. Off No li
Streszczenie treści zawartej na stronie nr. 14
Chapter 2: Hardware Installation and Setup Use the following guidelines to easily install the switch, ensuring that it has the proper power supply and environment. 2.1 Installation Overview Follow these steps to install the IntraCore IC39240/480 switch: 1. Open the box and check the contents. See Chapter 1.2 Package Contents for a complete list of the items included with the IntraCore IC39240/480 switch. 2. Install the switch in an equipment or wall rack, or prepare it for desktop plac
Streszczenie treści zawartej na stronie nr. 15
• Do not tamper with the equipment. Doing so could void the warranty • Examine the work area for potential hazards (such as wet floors or ungrounded cables) 2.1.2 Recommended Installation Tools You need the following additional tools and equipment to install the switch into an equipment rack: • Flat head screwdriver • Phillips head screwdriver • Antistatic mat or foam 2.1.3 Power Requirements The electrical outlet should be properly grounded, located near the switch and be easily acc
Streszczenie treści zawartej na stronie nr. 16
1. Place the switch on a flat, stable surface. 2. Locate a rack-mounting bracket (supplied) and place it over the mounting holes on one side of the switch. 3. Use the screws (supplied) to secure the bracket (with a Phillips screwdriver). 4. Repeat the two previous steps on the other side of the switch. 5. Place the switch in the equipment rack. 6. Secure the switch by securing its mounting brackets onto the equipment rack with the appropriate screws (supplied). Important: Make sure th
Streszczenie treści zawartej na stronie nr. 17
2.4 Connecting Power Important: Carefully review the power requirements (Chapter 2.1.3) before connecting power to the switch. Use the following procedure to connect power to the switch: • Plug one end of the supplied power cord into the power connector on the back of the switch. • Plug the other end into a grounded AC outlet. The power LED show the initialization is in process. The front panel LEDs blink and the power LED illuminates when it has initialized. The switch is ready for co
Streszczenie treści zawartej na stronie nr. 18
determine whether the device at the other end of the link is a hub, switch, or workstation, and adjust its signals accordingly. No crossover cables are required. Although 10/100BaseT requires only pins 1, 2, 3, and 6, you should use cables with all eight wires connected as shown in Table 2-2 below. 1000BaseT requires that all four pairs (8 wires) be connected correctly, using Category 5 or better Unshielded Twisted Pair (UTP) cable (to a distance of 100 meters). Table 2-2 shows the co
Streszczenie treści zawartej na stronie nr. 19
• 1000BaseLZ GBIC: Cables with SC-type fiber connectors; 10µ single-mode fiber media up to 120 km (393,701') • 1000BaseT: Category 5 or better Unshielded Twisted Pair (UTP) cable up to 100 m (328.1') When attaching a workstation to the switch, a standard straight-through CAT5 cable may be used, even when the workstation is attached via a patch panel. No crossover cable is needed with the MDX/MDI ports. The switch should be kept off the network until proper IP settings have been set. 19
Streszczenie treści zawartej na stronie nr. 20
Chapter 3: Initial Software Setup Configure the switch by connecting directly to it through a console (out-of-band management), running a terminal emulation program, such as HyperTerminal or by using telnet. 3.1 Connecting to a Console To connect the switch to a console or computer, set up the system in the following manner: 7. Plug power cord into the back of the switch. 8. Attach a straight-through serial cable between the RS232 console port and a COM port on the PC. 9. Set up a Hyper