Streszczenie treści zawartej na stronie nr. 1
User’s Guide
Shop online at
omega.com
e-mail: info@omega.com
For latest product maunuals:
omegamanual.info
LV850
Level Sensor
Streszczenie treści zawartej na stronie nr. 2
® OMEGAnet Online Service Internet e-mail www.omega.com info@omega.com Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: ® USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA ® Customer Service: 1-800-622-2378 / 1-8
Streszczenie treści zawartej na stronie nr. 3
LV850 LEVEL SENSOR Please follow these installation, connection and adjustment instructions carefully. Failure to comply with these instructions or misuse of this equipment will void your warranty. Equipment installation, connection and adjustment by qualified personnel only! i
Streszczenie treści zawartej na stronie nr. 4
LV850 LEVEL SENSOR NOTES: ii
Streszczenie treści zawartej na stronie nr. 5
LV850 LEVEL SENSOR 1 Description Level Sensor LV850 is suitable for liquids with low relative dielectric constant ε (e.g. oil). Units come with Minimum and Maximum selector switch. r It operates on the principle of electrical capacitance changes arising when an electrode surrounded by air is immersed in the medium. • LED status display • Selection of minimum and maximum function by changeover switch. Minimum switching Normally the sensor is immersed and the green LED indicates. As the level drop
Streszczenie treści zawartej na stronie nr. 6
LV850 LEVEL SENSOR 2 Technical Data Temperature range -20°C to +130 °C (-4°F to +266°F) short-time to +150°C (+302°F) Ambient temperature -20°C to +85°C (-4°F to +185°F) Pressure resistance max. 25 bar (367.5 PSI) Response delay approx. 0.1 s Degree of protection IP 65 Input voltage DC 9 ... 36 V Option: - metal coupling for pipe extension (see fig. 2) if the sensor is to be used as an immersion sensor mark to demonstrate compliance with applicable directive 2
Streszczenie treści zawartej na stronie nr. 7
LV850 LEVEL SENSOR 3 Level Sensor Installation NOTE The Level Sensor may be installed in any attitude. 1. Ensure sufficient clearance space (see Fig. 1) in the container wall. • Ensure a type 3/4" NPT or G3/4A thread in the container wall has been provided. 2. Screw the Level Sensor into the threaded aperture using a recognized sealing material. 3. When tightening the level sensor please use the flats provided (SW32). CAUTION Do not overtighten. 3
Streszczenie treści zawartej na stronie nr. 8
LV850 LEVEL SENSOR 4 Connection CAUTION Check that the supply voltage corresponds with the voltage rating shown on the system. 1. Loosen the gland (PG7)(see Fig. 1). 2. Unscrew the cover of the housing (C). 3. Feed the supply cable through the gland (PG7) and the cover (C), or through the metal coupling supplied as option (see Fig. 2). 4. Connect the cable to the terminal block (TB) (see Fig. 3). 5. Set selector switch (S) to minimum or maximum: 1. - minimum 2. - maximum 6. Connect the supply vo
Streszczenie treści zawartej na stronie nr. 9
LV850 LEVEL SENSOR 7. Increase the level until the Level Sensor is immersed in the medium. 8. Minimum Sensor: • Turn the potentiometer screw (E) to (-) until the LED (green) extinguishes. Then slowly turn to (+) until the LED indicates. Adjust the screw a further full turn to (+) to compensate for any tolerance. 9. Maximum Sensor: • Turn the potentiometer screw (E) to (+) until the LED (green) extinguishes. Then slowly turn to (-) until the LED indicates. Adjust the screw a further full turn to
Streszczenie treści zawartej na stronie nr. 10
LV850 LEVEL SENSOR NOTES: 6
Streszczenie treści zawartej na stronie nr. 11
WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department w
Streszczenie treści zawartej na stronie nr. 12
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www.omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Acc