Streszczenie treści zawartej na stronie nr. 1
Active Transmitter Combiner 8:1
AC 3200
Instruction manual
Streszczenie treści zawartej na stronie nr. 2
Streszczenie treści zawartej na stronie nr. 3
Contents Contents Important safety instructions ..................................................... 2 The AC 3200 active transmitter combiner 8:1 ......................... 5 Delivery includes ............................................................................. 5 Connection diagram ....................................................................... 6 Product overview ............................................................................ 7 Putting the AC 3200 into operati
Streszczenie treści zawartej na stronie nr. 4
Important safety instructions Important safety instructions 1. Read these instructions. 2. Keep these instructions. Always include these instructions when passing the device on to third parties. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use the device near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation openings. Install in accordance with these instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other devic
Streszczenie treści zawartej na stronie nr. 5
Important safety instructions Hazard warnings on the rear of the AC 3200 active transmitter combiner 8:1 The label shown on the left is attached to the rear of the AC 3200. The symbols on this label have the following meaning: This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the AC 3200’s enclosure that may be of sufficient magnitude to constitute risk of fire or electric shock. This symbol is intended to alert the user to the risk of electric s
Streszczenie treści zawartej na stronie nr. 6
Important safety instructions Intended use of the device Intended use of the AC 3200 includes: using the device for professional purposes, having read this instruction manual especially the chapter “Important safety instructions” on page 2, using the device within the operating conditions and limitations described in this instruction manual. “Improper use” means using the device other than as described in this instruction manual, or under operating conditions which differ from those described
Streszczenie treści zawartej na stronie nr. 7
The AC 3200 active transmitter combiner 8:1 The AC 3200 active transmitter combiner 8:1 With the AC 3200 active transmitter combiner, the signals of up to eight Sennheiser wireless monitoring transmitters can be combined onto a single antenna, e.g. the A2003UHF directional antenna, the A 1031 U omni-directional antenna or the A 5000 CP circularly polarized UHF antenna. For suitable transmitters, please refer to the AC3200 product page at www.sennheiser.com. The AC3200 allows you to make high-q
Streszczenie treści zawartej na stronie nr. 8
Connection diagram Connection diagram The below connection diagram shows the connections for an 8-channel system with a single antenna. AC 3200 6
Streszczenie treści zawartej na stronie nr. 9
Product overview Product overview 70 W Rack mount “ears” Air vents (on the sides) 8 LEDs: operation indicators of the RF inputs LED On/off switch IEC mains socket 8 RF inputs RF IN 1 to RF IN 8 for connecting the transmitters BNC socket for antenna output ANT 7
Streszczenie treści zawartej na stronie nr. 10
Putting the AC 3200 into operation Putting the AC 3200 into operation Preparing the AC 3200 for use You can set up the AC 3200 on an even surface or mount it into a 19" rack. Setting up the device CAUTION! Danger of heat damage to the devices! During operation, the AC 3200 and the connected transmitters produce considerable waste heat! If this heat cannot dissipate, it can cause damage to the devices! The devices are equipped with fans to assist dissipation of generated heat: Make sure that t
Streszczenie treści zawartej na stronie nr. 11
Putting the AC 3200 into operation Ensure that the base of the AC 3200 is clean and free from grease before fitting the rubber feet. Fix the rubber feet to the base of the AC 3200 by peeling off the backing paper and fitting them as shown in the diagram on the left. Place the AC 3200 on an even, horizontal surface. Rack-mounting CAUTION! Risks when rack mounting the AC 3200! When installing the device in a closed or multi-rack assembly, please consider that, during operation, the ambient t
Streszczenie treści zawartej na stronie nr. 12
Putting the AC 3200 into operation To mount the AC 3200 into a 19" rack: Slide the AC 3200 into the 19" rack. Secure the rack mount “ears” to the rack using four screws (not included). Connecting the antenna CAUTION! Danger of damage to the devices! Do not daisy-chain several AC3200. Do not connect other active combiners to the AC 3200. Never connect the AC3200 to other active combiners. Only connect suitable antennas to the output of the AC 3200! The AC 3200 active transmitter combiner
Streszczenie treści zawartej na stronie nr. 13
Putting the AC 3200 into operation 70 W Connecting the mains cable Connect the suitable mains cable to the IEC mains socket and to the mains. 70 W Note: The AC 3200 can be connected to any mains power supply with 100 V to 240 V AC (50 to 60 Hz). Switching the AC 3200 on and off Press the on/off switch . The AC 3200 switches on and the LED lights up red. Press the on/off switch again. The AC 3200 switches off and the LED goes off. Note: After switch-off, the AC 3200
Streszczenie treści zawartej na stronie nr. 14
Recommendations and tips for optimum reception Recommendations and tips for optimum reception There should be a “free line of sight” between transmitting and receiving antennas. To avoid overloading the receiver, observe a minimum distance of 5 m between transmitting and receiving antennas. Observe a minimum distance of 50 cm between the transmitting antenna and metal objects (such as cross members or reinforced-concrete walls). When using a multi-channel system: Set all transmitters of you
Streszczenie treści zawartej na stronie nr. 15
If a problem occurs ... If a problem occurs ... Problem Possible cause Possible solution The LED does The AC 3200 doesn’t consume Check if the AC 3200 is not light up current connected to the mains and if the on/off switch is pressed Extra LEDs light up The transmitting antenna Check that the transmitting for RF inputs which is not connected, the antenna is correctly connected, are not in use transmitting antenna is is not damaged, and that the faulty or the wrong type, connecting ca
Streszczenie treści zawartej na stronie nr. 16
Accessories and spare parts Accessories and spare parts The following accessories are available from your Sennheiser partner: Cat. No. Accessory/spare part 003658 A 2003 UHF passive directional antenna 004645 A 1031 U passive omni-directional antenna 500887 A 5000 CP circularly polarized UHF antenna 002324 GZL 1019-A1 BNC-BNC coaxial cable, type RG 58, length 1 m 14
Streszczenie treści zawartej na stronie nr. 17
Specifications Specifications Frequency range 500 – 870 MHz Distribution attentuation 0 dB (±1 dB) RF input power nominal value up to 100 mW per input inputs protected up to max. 250 mW Impedance 50 Ω Power supply 100 V – 240 V AC, 50 – 60 Hz Power consumption max. 70 W Temperature range 0 °C to 45 °C Weight approx. 4 kg Type approvals Area Conformity USA: FCC-Part 74.861 FCC ID: DMOAC3200 / limited to 698 MHz! Canada: RSS-123 IC: 2099A-AC3200 EU: 0682 complies with the requirements for radio a
Streszczenie treści zawartej na stronie nr. 18
Manufacturer Declarations Manufacturer Declarations Warranty Sennheiser GmbH & Co. KG gives a warranty of 24 months on this product. For the current warranty conditions, please visit our web site at www.sennheiser.com or contact your Sennheiser partner. CE Declaration of Conformity 0682 This equipment is in compliance with the essential requirements and other relevant provisions of Directives 1999/5/EC and 2006/95/EC. The declaration is available on the internet site at www.sennheiser.com. Befor
Streszczenie treści zawartej na stronie nr. 19
Streszczenie treści zawartej na stronie nr. 20
Sennheiser electronic GmbH & Co. KG Am Labor 1, 30900 Wedemark, Germany Phone: +49 (5130) 600 0 Printed in Germany Fax: +49 (5130) 600 300 Publ. 09/08 www.sennheiser.com 528244/A01