Streszczenie treści zawartej na stronie nr. 1
A50-62113-00007
6262/6262-212/6260/6260-212
User Manual
en
Streszczenie treści zawartej na stronie nr. 2
Important safety instructions CAUTION: High voltage! Risk of death! High voltages of up to 500 V DC may be present inside the casing for long periods after being disconnected from the mains. To avoid lethal electric shock, do not open the casing. There are no user-serviceable components inside. Refer all maintenance to qualified service personnel. Remove the mains cable when the unit is not in use. WARNING: To eliminate the risk of fire and electric shock, do not expose this unit to rain or m
Streszczenie treści zawartej na stronie nr. 3
Table of contents IMPORTANT NOTICE! ........................................................................ 4 Introduction ..................................................................................... 4 Before you get started .......................................................................................................4 Online registration .............................................................................................................4 Control elements ............
Streszczenie treści zawartej na stronie nr. 4
Please ensure proper disposal of all packing $ IMPORTANT NOTICE! materials. FAILURE TO OBSERVE THE FOLLOWING POINTS MAY RE- Ensure adequate air supply and to avoid overheating do SULT IN DAMAGE TO THE AMPLIFIER OR LOUDSPEAK- not place the unit near radiators etc. ERS. DAMAGES CAUSED IN SUCH A WAY ARE NOT COV- Please make sure that all devices are properly ERED BY WARRANTY. $ grounded. For your own safety, never remove Before you start, always make sure that your or disable the ground cond
Streszczenie treści zawartej na stronie nr. 5
Control elements Front panel of the BUGERA 6260 13 This GAIN control specifies the input level of the Front panel CLEAN channel. Turn the control to the right to in- 1 The POWER switch is used to turn the power of the crease the preamplifier’s distortion and sustain. BUGERA amplifier on and off. Please note that extremely high GAIN settings $ 2 The STANDBY switch allows you to place the amp in conjunction with extremely high VOLUME in STANDBY mode. This way the amp is idle, but the settin
Streszczenie treści zawartej na stronie nr. 6
Rear panel of the BUGERA 6260 Rear panel * 24 WARNING: ONLY REPLACE THE FUSE WHEN THE CAUTION! MAINS CABLE HAS BEEN DISCONNECTED! The FUSE is found in the fuse holder. If the fuse is ! blown, it needs to be replaced with a fuse of the Hot! Risk of injury! During use, the valves same kind by all means. Otherwise, the unit could get very hot and high surface temperatures seriously be damaged, in which case the warranty may be reached at the rear of this unit. is void. If the fuse is bl
Streszczenie treści zawartej na stronie nr. 7
Inside the BUGERA 6260 Inside the BUGERA INSTRUCTIONS FOR QUALIFIED SERVICE PERSONNEL ONLY DANGER! Remove the backside of the amplifier’s casing to get to * High voltage! Risk of death! the valves and the control elements. 32 These are the sockets for the 12AX7A/B/C pre- amp valves. High voltages of up to 500 V DC may be present inside the casing for long periods 33 These are the sockets for the 6L6 and EL34 power after being disconnected from the mains. amp valves. Please take care that
Streszczenie treści zawartej na stronie nr. 8
Wiring the BUGERA CAUTION! ! Hot! Risk of injury! During use, the valves will get very hot and high surface temper- atures may be reached at the rear of this unit. To avoid burning yourself, make all connections while the unit is still cold. ATTENTION! TO AVOID DAMAGE TO YOUR AMP, NEVER USE THE BUGERA VALVE AM- ! PLIFIER WITHOUT A LOUDSPEAKER CON- NECTED! The BUGERA amplifier has two paralleled LOUDSPEAKER outputs which are used to connect one or two speaker cabinets. If you only connect
Streszczenie treści zawartej na stronie nr. 9
The following figure shows a setup of the 6262-212 to- Audio connections gether with an external effects unit connected over the FX LOOP. And the PREAMP OUT is connected to the line The inputs and outputs of the BUGERA amplifier use input of a mixer in order to send the signal to a recording mono jack connectors. device. In addition, the speaker signal of the BUGERA is picked up by a microphone and is fed to the microphone input of the mixer. This way you get a second guitar sig- nal which
Streszczenie treści zawartej na stronie nr. 10
Specifications PREAMP SECTION Valves Type 1 x 12AX7A 1 x 12AX7B 3 x 12AX7C (6260 and 6260-212) 4 x 12AX7C (6262 and 6262-212) Preamp high-gain input Impedance 470 kΩ Clean channel Nominal input level -34 dBV Min. input level -50 dBV Max. input level 0 dBV Lead channel Nominal input level -80 dBV Min. input level -92 dBV Preamp low-gain input (only 6260 and 6260-212) Impedance 44 kΩ All levels attenuated by +6 dB Effects send Impedance 47 kΩ or higher Nominal output l
Streszczenie treści zawartej na stronie nr. 11
Limited warranty SPECIAL NOTE: NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. § 1 Other warranty rights and national law 1. This limited warranty does not exclude or limit the buyer’s statutory rights provided by national law, in particular, any such rights against the seller that arise from a legally effective purchase contract. 2. The limited warranty regulations mentioned herein are applicable unless they constitute an infringement of national warranty law. §
Streszczenie treści zawartej na stronie nr. 12
FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION BUGERA 6262/6262-212/6260/6260-212 Responsible party name: MUSIC Group Services USA, Inc. Address: 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone/Fax No.: Phone: +1 425 672 0816 Fax: +1 425 673 7647 BUGERA 6262/6262-212/6260/6260-212 complies with the FCC rules as mentioned in the following paragraph: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 1