Streszczenie treści zawartej na stronie nr. 1
102RAS
Industrial
Remote Access Server
User Manual &
Installation
Guide
(Revised 2010-11-15) page 1 of 30
Streszczenie treści zawartej na stronie nr. 2
Table of Contents Industrial Remote Access Server Installation Guide .....................................................................................3 General Safety Warnings ...............................................................................................................................4 Environmental Safety.....................................................................................................................................5 Electrical Safety ......
Streszczenie treści zawartej na stronie nr. 3
Industrial Remote Access Server Installation Guide 102RAS The N-TRON 102RAS provides connectivity to an industrial LAN for telecommuters or mobile users, or to remotely installed equipment, via an integrated V.92/56K modem. The small size of the 102RAS makes it ideal for placing alongside other industrial equipment to be accessed remotely. Product Features LAN Port: 10/100BaseT; RJ-45 WAN Port: V92/56K modem; RJ-11 Rates: D
Streszczenie treści zawartej na stronie nr. 4
Copyright, © N-Tron Corp., 2008 820 S. University Blvd., Suite 4E Mobile, AL 36609 USA All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-Tron Corp. is prohibited, except as allowed under copyright laws. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks of their respective owners. The information contained in this
Streszczenie treści zawartej na stronie nr. 5
Environmental Safety WARNING: Disconnect the power and allow to cool 5 minutes before touching. Electrical Safety WARNING: Disconnect the power cable before removing any modules, or any enclosure panel. WARNING: Do not operate the unit with the cover removed. WARNING: Properly ground the unit before connecting anything else to the unit. Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty. See the grounding techniq
Streszczenie treści zawartej na stronie nr. 6
5. Class I, Div 2 Installations require that power connections must be current limited at the power source with an in-line fuse rated at 0.5A. 6. Class I, Div 2 installations require that all devices connected to this product must be UL listed for the area in which it is installed. 7. Use 60/75ºC rated Copper wire, (022Nm) 2 inch-lbs Tightening torque for field installed connectors. 8. Limited Operating Voltage: 10-30V for Class I, Div 2 installations. 9. This apparatus is su
Streszczenie treści zawartej na stronie nr. 7
DIN Rail Mounting Install the unit on a standard 35mm DIN rail. Recess the unit to allow at least 3” of horizontal clearance for cable bend radius. To mount the unit to the 35mm DIN rail, To remove the unit from the 35mm DIN rail, typically place top edge of the brackets on the back of the it is possible to remove the unit by using your index and unit against the DIN rail at a 45° upward angle. middle fingers or use flat head screwdrivers
Streszczenie treści zawartej na stronie nr. 8
Front Panel From Top to Bottom: Green LED lights when Power is supplied to the module RJ-45 Port Auto sensing 10/100 Base-TX Connection RJ-11 Port Phone line connection TR Transmit Ready CD Carrier Detect TX Transmit RX Receive Note: The RJ45 data port has two LED’s located at the side of the connector. The bottom LED indicates LINK status, and the top LED indicates ACTIVITY. LED’s: The table below describes the operati
Streszczenie treści zawartej na stronie nr. 9
Applying Power (Top View) Remove Supplied #6 Phillips head grounding screw from top of unit. Connect ground wire with lug (not supplied) and re-install the grounding screw securely. Unscrew & Remove the DC Voltage Input Plug from the Power Input Header Install the DC Power Cables into the Plug (observing polarity). Plug the Voltage Input Plug back into the Power Input Header. Tightening torque for the terminal block power plug is 0.22 Nm/0.162 Pound Foot. Verify the Po
Streszczenie treści zawartej na stronie nr. 10
N-TRON SWITCH GROUNDING TECHNIQUES The grounding philosophy of any control system is an integral part of the design. N-Tron switches are designed to be grounded, but the user has been given the flexibility to float the switch when required. The best noise immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to earth ground via a drain wire. Some N-Tron switches have metal din-rail brackets that can ground the switch if the din-rail is grounded
Streszczenie treści zawartej na stronie nr. 11
RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications: (Revised 2010-11-15) page 11 of 30
Streszczenie treści zawartej na stronie nr. 12
Overview of Features Compact Remote Access Solution The 102RAS includes one integrated V.92/56K modem, housed in a compact, industrial chassis which provides V.92/56K download speeds and 48K upload speeds when connecting with V.92 servers. Dial-in users can achieve V.34/33.6K connections. Unit ships with 35mm DIN rail connector suitable for mounting the unit on 35mm DIN rail in industrial environment. Secure Remote Access The 102RAS has a built-in security database for us
Streszczenie treści zawartej na stronie nr. 13
Troubleshooting 1. Make sure the (Power LED) is ON. 2. Make sure you are supplying sufficient current. Note: The Inrush current will exceed the steady state current by ~ 2X. 3. Verify that Link LED’s are ON for connected ports. 4. Verify cabling used between stations. 5. Verify the phone socket that the phone line from the 102RAS is plugged into is operational. 6. Verify that cabling is Category 5E or greater for 100Mbit Operation. Support: Contact N-Tron Corp. at: TEL:
Streszczenie treści zawartej na stronie nr. 14
Regulatory Statements 47 CFR Part 15 Regulation This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Industry Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-o003 du
Streszczenie treści zawartej na stronie nr. 15
9. If your home or office has specially wired alarm equipment connected to the telephone line, ensure the installation of this equipment does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer. 10. This equipment is hearing aid compatible. 11. Manufacturing Information: Manufacturer: N-Tron Corp. Trade Name: 102RAS Model Number: 102RAS Registration No: AU7USA-25814-M5-E
Streszczenie treści zawartej na stronie nr. 16
restricted to lower bit rates when connected to some PSTN implementations. Telecom will accept no responsibility should difficulties arise in such circumstances. 2. Immediately disconnect this equipment should it become physically damaged, and arrange for its disposal or repair. 3. This modem shall not be used in any manner which could constitute a nuisance to other Telecom customers. 4. This device is equipped with pulse dialing, while the Telecom standard is DTMF tone dialing.
Streszczenie treści zawartej na stronie nr. 17
China Approved 20650004500320 China NALTE Approved 10-6066-060989 Cyprus Approved CE Czech Republic Approved CE Denmark Approved CE Estonia Approved CE Finland Approved CE France Approved CE Germany Approved CE Greece Approved CE Hong Kong Approved SL 300063 Hungary Approved CE Iceland Approved CE India Approved TEC/NR/I/MOD-08/01/082.JUL03 Indonesia Approved 01144/1/POSTEL/2003 Ireland Approved
Streszczenie treści zawartej na stronie nr. 18
Software Configuration Web Management Enter the switch’s IP address in any web browser and login to the web management feature of the 102RAS. Default: Username: admin Password: admin (Revised 2010-11-15) page 18 of 30
Streszczenie treści zawartej na stronie nr. 19
Web Management - Home When the administrator first logs onto the 102RAS, the default home page is displayed. At the top of the screen there is a list of configurable settings which the 102RAS supports. This section of the manual will go through each choice listed at the top of the screen and explain how to configure those settings. In the center of the main home page the administrator/user can see some basic information like what firmware revision the 102RAS is running. (Revis
Streszczenie treści zawartej na stronie nr. 20
Web Management – Menu Structure Home Shows information about the manufacturer and the 102RAS, along with support Website and E-Mail addresses. Login Brings up the Login page Logout Logs off the current user Administration IP Configuration – Shows the current IP Configuration and allows User to change. SMTP Configuration – Shows the current SMTP Configuration and allows User to change. Time Configuration – Shows the current Time Configuration and allows User t