Streszczenie treści zawartej na stronie nr. 1
GVI dba Samsung CCTV
1621 West Crosby, Suite 104
Carrollton, TX 75006
Printed in Korea
PHONE : 866-492-8246
Part No. :14021-1205
Streszczenie treści zawartej na stronie nr. 2
B/W OBSERVATION SYSTEM Installation Manual SSC-12
Streszczenie treści zawartej na stronie nr. 3
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. Graphic Symbol Explanation The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated ‘dangerous voltage’ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock t
Streszczenie treści zawartej na stronie nr. 4
IMPORTANT SAFEGUARDS Caution Power source is indicated on the rear of the set. It contains high-voltage parts. If you remove the cover, it may cause fire or electric shock. Do not remove the cover by yourself. (Control switches are at the front of the monitor). 1. Read Instructions : All the safety and operating instructions should be read before E the appliance is operated. 2. Retain Instructions : The safety and operating instructions should be retained for future reference. 3. Heed Warnings
Streszczenie treści zawartej na stronie nr. 5
9. Ventilation : Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the monitor and to protect it from overheating, and these openings should never be blocked by placing the monitor on a bed, sofa, rug, or other similar surface. This monitor should never be placed near or over a radiator or heat register. This monitor should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or SAMSUNG’s instru
Streszczenie treści zawartej na stronie nr. 6
16. Servicing : Do not attempt to service this monitor yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. 17. Damage Requiring Service : Unplug this monitor from the wall outlet and refer servicing to qualified service personnel under the following conditions. a. When the power-supply cord or plug is damaged. b. If liquid has been spilled, or objects have fallen into the monitor. c. If the monitor has b
Streszczenie treści zawartej na stronie nr. 7
FCC & ICES Information Warning This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC Rules and ICES-003 of Industry Canada. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interferen
Streszczenie treści zawartej na stronie nr. 8
Contents E IMPORTANT SAFEGUARDS..................................................... 3 1. System Components and Installation ........................................ 8 1-1. System Components........................................................... 8 1-2. System Configuration ........................................................ 9 1-3. Individual Component Installation................................... 10 1-4. Basic System Installation................................................. 13 2.
Streszczenie treści zawartej na stronie nr. 9
1. System Components and Installation 1-1. System Components STANDARD CAMERA MONITOR CAMERA CABLE CAMERA MOUNT BRACKET INSTALLATION MANUAL Alarm Terminal-BLOCK 8
Streszczenie treści zawartej na stronie nr. 10
1-2. System Configuration Model Name Quantity Note Monitor SSC-12M 1 Standard Camera SSC-12C 3 Camera Mount Bracket SBR-110 3 Camera Cable MCB-60 3 E Installation Manual 1 9
Streszczenie treści zawartej na stronie nr. 11
1-3. Individual Component Installation 1) INSTALLING STANDARD CAMERA (SSC-12C) Caution to install SSC-12C outdoors 1. SSC-12C is designed to be protected from the water drops which are falling on the upper side of camera in a range of 15 . (Dust-water protection level : IP42) Therefore, be sure to install it in a location which is fit in above condition when you install it outdoor. SSC-12C camera can be attached to the wall, ceiling or shelf using the camera mount bracket (SBR-110). Choose an
Streszczenie treści zawartej na stronie nr. 12
2) CAMERA MOUNT BRACKET(SBR-110) & STANDARD CAMERA (SSC-12C) ! Overview CAMERA MOUNT BRACKET (SBR-110) is used to attach the camera to a wall, ceiling or shelf. @ Installation Explains the installation of CAMERA MOUNT BRACKET as well as the installation of the camera onto the CAMERA MOUNT BRACKET. E Choose an installation site that can sufficiently support the weight of the equipment to be installed. Attach the camera mount bracket to the wall using the supplied screws (M4 X L15). Adjus
Streszczenie treści zawartej na stronie nr. 13
Loosen the handle by turning it in a counter clockwise direction and then adjust the camera position. Tighten the handle, turning it clockwise, and lock the camera in position. Connect the camera cable to the camera. Handle # Specifications Use : Indoor Installation : Wall or Ceiling Dimensions : 57(W) ✕ 47.2(H) ✕ 100.5(L) Weight : 150g Operating Temperature : -10 ~ 50 $ Accessories SCREW (M4 ✕ L15) 3 pcs 12
Streszczenie treści zawartej na stronie nr. 14
1-4. Basic System Installation Perform the following steps to install your system. Take the monitor out of the packaging box. Place the monitor where you would like to install it. Do not turn on power until installation is complete Choose the place where you want to install the camera. Once the monitor and camera locations have been chosen, install the camera. Connect the cable to the jack on the back of the camera. E Connect the other end to CAMERA IN on the back of the monitor. (At
Streszczenie treści zawartej na stronie nr. 15
2. Connecting Peripheral Devices 2-1. Connecting a PIR Sensor Camera alarm in jack Sensor Sensor input Mount on the camera - An additional PIR sensor or external sensor can also be connected. - The additional PIR sensor can be connected as shown in the above graphic. - Sensor’s trigger signal is NO (Normal Open). - Sensor is not supplied. (Sold separately) 2-2. Connecting a VCR - Connect the VCR as shown below. 14
Streszczenie treści zawartej na stronie nr. 16
3. Part Names and Functions 3-1. Camera Standard Camera c E a f b e d PIN NUMBER SPEC 1 SPEAKER(HOT) 2 VIDEO_OUT 3 GND 4 SPEAKER(COLD) 5 AUDIO_OUT/ALARM_OUT 6 12V DC a Lens It has a focal length of 3.8mm and makes it possible for you to observe a relatively wide area. b Microphone Capable of picking up all sound in the vicinity of the camera location and transmitting to the monitor. c Camera fitting groove Enables the camera to be fixed onto the
Streszczenie treści zawartej na stronie nr. 17
3-2. Monitor Front ! BRIGHT Adjust brightness with this knob. @ CONT. Adjust contrast with this knob. # AUDIO Adjust volume control for proper sound level. $ H-HOLD This control permits adjustment of horizontal stability. % TALK/A.RESET TALK : Talk to selected channel. A.RESET : Reset Alarm. ^ VCR This button is used to display recorded data in the VCR on the monitor. 16
Streszczenie treści zawartej na stronie nr. 18
& AUTO This monitor normally will be in AUTO mode, which means it switches cameras automatically. Press this button if you want to rescan camera port. This monitor will automatically skip the cameras that are not connected, and the ALARM mode is automatically activated in AUTO mode. E * CAMERA SELECT(C1~C4) If you want press any camera selector button, this monitor goes into manual mode. Press AUTO button if you want to return to auto mode. ( ALARM/TIME ALARM : Press this butto
Streszczenie treści zawartej na stronie nr. 19
3-3. Monitor Rear ! CAMERA IN (CAM1~CAM4) Four input ports for four cameras. (6 Pin Modular Jack) @ AUDIO IN/OUT//VIDEO IN/OUT AUDIO IN/OUT : Audio in/out ports for VCR recording and playing. VIDEO IN/OUT : Video in/out ports for VCR recording and playing. # V-HOLD Use to correct when the picture rolls up and down. $ AC POWER CORD Power cord. % MAIN POWER Main power switch. When power on, initial mode is switching screen. 18
Streszczenie treści zawartej na stronie nr. 20
4. Operation Function Instruction ! INITIAL STATUS If you turn on this monitor, it search cameras. If all cameras weren't connected to monitor, this screen display channel 1. @ SEQUENTIAL SWITCHING MODE E Please press AUTO button, the monitor goes to sequential switching mode and the yellow LED lamp of AUTO button will on. The sequential switcher built in the monitor allows each camera to show the pictures sequentially. If a camera is disconnected from the monitor