Streszczenie treści zawartej na stronie nr. 1
®
Powerware 9315 UPS
500–750 kVA
Installation and Operation Manual
Streszczenie treści zawartej na stronie nr. 2
IMPORTANTSAFETYINSTRUCTIONS SAVETHESEINSTRUCTIONS Thismanualcontainsimportantinstructionsthatyoushouldfollowduringinstallationandmaintenanceof theUPSandbatteries.Pleasereadallinstructionsbeforeoperatingtheequipmentandsavethismanualfor futurereference. CONSIGNESDESÉCURITÉIMPORTANTES CONSERVERCESINSTRUCTIONS Cemanuelcomportedesinstructionsimportantesquevousêtesinvitéàsuivrelorsdetouteprocédure d’installationetdemaintenancedesbatteriesetdel’onduleur.Veuillezconsulterentièrementces instructionsavant
Streszczenie treści zawartej na stronie nr. 3
SpecialSymbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISKOFELECTRICSHOCK-Indicates that a risk of electric shock is present and the associated warning should be observed. CAUTION: REFERTOOPERATOR’SMANUAL -Refer to your operator’s manual for additional information, such as important operating and maintenance instructions. This symbol indicates that you should not discard the UPS or the UPS batteries in the trash. This product c
Streszczenie treści zawartej na stronie nr. 4
This page intentionally left blank.
Streszczenie treści zawartej na stronie nr. 5
Table of Contents 1 Introduction ........................................................................... 1-1 1.1 UPSFeatures ......................................................................................... 1-2 1.1.1 InstallationFeatures ............................................................................... 1-2 1.1.2 CustomerInterface ................................................................................ 1-2 1.1.3 CustomerConvenienceOutlet..........................
Streszczenie treści zawartej na stronie nr. 6
TABLE OF CONTENTS 6 InstallingOptionalAccessories ........................................................... 6-1 6.1 InstallinganRMP ...................................................................................... 6-2 6.2 InstallinganRIM ...................................................................................... 6-5 6.3 InstallinganSCM ...................................................................................... 6-7 6.4 InstallingX-SlotCards............................
Streszczenie treści zawartej na stronie nr. 7
TABLE OF CONTENTS 11 RespondingtoSystemEvents ............................................................. 11-1 11.1 SystemEventHorns .................................................................................... 11-1 11.2 SystemEventIndicators ................................................................................. 11-1 11.3 SystemEventMessages ................................................................................. 11-1 12 Communication ................................
Streszczenie treści zawartej na stronie nr. 8
TABLE OF CONTENTS 14 ProductSpecifications .................................................................. 14-1 14.1 ModelNumbers ....................................................................................... 14-1 14.2 UPSSystemInput ...................................................................................... 14-1 14.3 UPSSystemOutput..................................................................................... 14-2 14.4 EnvironmentalSpecifications...................
Streszczenie treści zawartej na stronie nr. 9
List of Figures Figure1-1.TypicalPowerware9315(500–750kVA)UPSSystem .................................................. 1-1 Figure2-1.CabinetasShippedwithOuterPackagingandPallet................................................... 2-2 Figure4-1.RemoteBatteryDisconnectEnclosure ............................................................. 4-1 Figure5-1.RemoteEmergencyPower-off(REPO)Control ........................................................ 5-1 Figure5-2.REPOWiring .............................
Streszczenie treści zawartej na stronie nr. 10
LIST OF FIGURES FigureA-10.SecuringCables ........................................................................... A-18 FigureA-11.CB2TBtoDCSourceDisconnectDevice........................................................... A-21 FigureA-12.Inverter/RectifierCabinet–PCM1Terminals....................................................... A-22 FigureA-13.Inverter/RectifierCabinet–PCM1Terminals(continued) .............................................. A-23 FigureA-14.Output/InverterCabinet–PCM2Termina
Streszczenie treści zawartej na stronie nr. 11
Chapter 1 Figure1Table1 Introduction ® ® The Eaton Powerware 9315 (500–750 kVA) uninterruptible power supply (UPS) is an online power protection system that prevents loss of valuable electronic information, minimizes equipment downtime, and minimizes the adverse effect on equipment production because of unexpected power problems. The Powerware 9315 UPS system continually monitors incoming electrical power and removes the surges, spikes, sags, and other irregularities that are inherent in commerc
Streszczenie treści zawartej na stronie nr. 12
INTRODUCTION 1.1 UPS Features The UPS has many standard features that provide cost-effective and consistently reliable power protection. The descriptions in this section provide a brief overview of the UPS standard features. 1.1.1 Installation Features Power wiring can be routed through the top of each cabinet. External sensing and monitoring control wire must be installed according to UL Class I requirements. Class I wiring can be routed through the top of each cabinet. 1.1.2 Customer Interface
Streszczenie treści zawartej na stronie nr. 13
INTRODUCTION 1.2 Options and Accessories Contact your Eaton sales representative for information about the following options: 1.2.1 5% Input Filter The UPS can be equipped with an input filter. An input filter yields power factor correction that allows you to save on your initial installation and operating costs. The filter also reduces input harmonic current distortion and minimizes upstream interference that can damage sensitive hardware components. 1.2.2 Battery Racks You can enhance the prot
Streszczenie treści zawartej na stronie nr. 14
INTRODUCTION 1.2.6 Monitoring and Communication The following monitoring and communication options are available: S RemoteMonitorPanel(RMP) – An optional RMP contains backlit status indicators and a local horn, allowing you to monitor the UPS operational status and alarm condition from virtually any location within your facility. This option is described further in Chapter 10, “Using Features and Options.” S RelayInterfaceModule(RIM) – An optional RIM uses relay contact closures to indicate the
Streszczenie treści zawartej na stronie nr. 15
INTRODUCTION 1.4 Safety Warnings IMPORTANTSAFETYINSTRUCTIONS SAVETHESEINSTRUCTIONS S Thismanualcontainsimportantinstructionsthatshouldbefollowedduringinstallationandmaintenance oftheUPSandbatteries.Pleasereadallinstructionsbeforeoperatingtheequipmentandsavethis manualforfuturereference. S TheUPScabinetisdesignedforindustrialorcomputerroomapplicationsandcontainssafetyshields behindthefrontdoors.However,theUPSsystemisasophisticatedpowersystemandshouldbehandled withappropriatecare. DANGER ThisUPSco
Streszczenie treści zawartej na stronie nr. 16
INTRODUCTION AVERTISSEMENT! S Lesbatteriespeuventprésenterunrisquededéchargeélectriqueoudebrûlurepardescourts-circuitsde hauteintensité.Prendrelesprécautionsnécessaires. S Pourleremplacement,utiliserlemêmenombreetmodéledesbatteries. ATTENTION! S Unemiseaurebutréglementairedesbatteriesestobligatoire.Consulterlesrèglementsenvigueurdans votrelocalité. S Nejamaisjeterlesbatteriesaufeu.L’expositionauxflammesrisquedelesfaireexploser. 1.5 Conventions Used in This Manual This manual uses these type conv
Streszczenie treści zawartej na stronie nr. 17
INTRODUCTION 1.7 Getting Help If you need help with any of the following: S Scheduling initial startup S Regional locations and telephone numbers S A question about any of the information in this manual S A question this manual does not answer Please call the Eaton Help Desk for Powerware products at: United States: 1-800-843-9433 or1-919-870-3028 Canada: 1-800-461-9166 ext 260 All other countries: Call your local service representative ® EATON Powerware 9315 UPS (500–750 kVA) Installation and O
Streszczenie treści zawartej na stronie nr. 18
INTRODUCTION This page intentionally left blank. ® 1-8 EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com
Streszczenie treści zawartej na stronie nr. 19
Section I Installation ® EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com 1-1
Streszczenie treści zawartej na stronie nr. 20
® 1-2 EATON Powerware 9315 UPS (500–750 kVA) Installation and Operation Manual S 164201691 Rev 1 www.powerware.com