Streszczenie treści zawartej na stronie nr. 1
PROFESSIONAL WEATHER CENTER
WS-1612
Operation Manual
Streszczenie treści zawartej na stronie nr. 2
Table of Contents Topic Page Features 3 Setting up 6 Function keys 12 LCD Screen 14 Manual Setting 16 Time alarm setting 24 Weather alarm operations 25 Hysteresis 31 Weather forecast and weather tendency 32 Wind direction and wind speed measurement 36 Rainfall measurement 37 Viewing history data 37 Viewing the min/ max weather data 39 Switch On/ Off buzzer 46 Outdoor transmission 915 MHz reception 48 Positioning 49 Care and Maintenance 53 Specification 54 Warranty Info 57
Streszczenie treści zawartej na stronie nr. 3
PROFESSIONAL WEATHER CENTER Instruction Manual Congratulations on purchasing this state-of-the-art Professional Weather Center as an example of excellent design and innovative technology. Featuring time, date, calendar, weather forecast, wind direction and speed, rainfall, outdoor temperature and outdoor humidity, air pressure and various alarm settings for different weather conditions, this Weather Center will provide you with extensive weather information and forecast. INSTAN
Streszczenie treści zawartej na stronie nr. 4
FEATURES: Weather Center Hanging hole Foldout stand LCD Battery compartment cover Function keys • Time display (manual setting) • 12/24 hour time display • Calendar display (weekday, date, month, year) • Time alarm function • Weather forecasting function with 3 weather icons and weather tendency indicator • Outdoor temperature display in ºF/°C • Outdoor Humidity display as RH% 3
Streszczenie treści zawartej na stronie nr. 5
• MIN/MAX value of outdoor temperature and humidity display with time & date of recording • Low/High outdoor temperature and humidity alarm • Relative air pressure displayed in inHg or hPa • Air pressure tendency indicator for the past 12 hours (bargraph format) • LCD contrast selectable • Low battery indicator • Wind direction displayed in 16 steps • Wind speed displayed in mph, km/h, or m/s, and Beaufort scale • Wind chill displayed in °F of °C • Max wind speed displayed with time &
Streszczenie treści zawartej na stronie nr. 6
Wind Sensor • Connected to the thermo-hygro sensor by cable • Can be installed onto a mast or a horizontal panel Rain Sensor • Connected to the thermo-hygro sensor by cable • To be mounted onto a horizontal panel 5
Streszczenie treści zawartej na stronie nr. 7
SETTING UP: Wireless transmission at 915 MHz - thermo-hygro sensor to the Weather Center Weather Center Rain Sensor Wind Sensor Cable connection between Cable connection between the wind sensor and the the rain sensor and the thermo-hygro sensor thermo-hygro sensor Note: When putting the Weather Center into operation, it is important to perform in close proximity (e.g. on a table) a complete wiring and set-up of the system. This step is
Streszczenie treści zawartej na stronie nr. 8
important to test all components for correct function before placing and mounting them at their final destinations (See Positioning below) 1. Unwind the cables of the rain and the wind sensors. Connect the rain and the wind sensors to the thermo-hygro sensor by plugging the connector heads of the two sensors into the appropriate sockets of the thermo-hygro sensor. Sockets for wind and rain sensor 2. First insert the batteries into the thermo-hygro sensor (see “Ho
Streszczenie treści zawartej na stronie nr. 9
displayed on the Weather Center. If this does not happen after 30 seconds, the batteries will need to be removed from both units. You will have to start again from step 1. 5. You may then check all cables for correct connection and all components for correct function by manually turning the wind-gauge, moving the weather-vane, tilting the rain sensor to hear the impact of the internally moving seesaw, etc (See Positioning below). 6. Time and date shall be manually set (See Manual Setting
Streszczenie treści zawartej na stronie nr. 10
obstructions and that radio waves DO NOT curve around objects. Actual transmission range will vary depending on what is in the path of the signal. Each obstruction (roof, walls, floors, ceilings, thick trees, etc.) will effectively cut signal range in half. Example: A Professional Weather Center with a 330 feet range is mounted on an interior wall, so that the signal has to pass through one interior wall, one exterior wall, and across the 10 feet width of the room between the 2 walls
Streszczenie treści zawartej na stronie nr. 11
• After batteries are installed, there will be synchronization between Weather Center and the sensor. At this time, the signal reception icon will be blinking. When the signal is successfully received by the Weather Center, the icon will be switched on. (If it is not successful, the icon will not be shown in LCD) So the user can easily see whether the last reception was successful (icon on) or not (icon off). On the other hand, the short blinking of the icon shows that a reception is in pr
Streszczenie treści zawartej na stronie nr. 12
1. Remove the battery compartment cover. 2. Insert the batteries observing the correct polarity (see the marking in the battery compartment). 3. Replace the battery cover. HOW TO INSTALL AND REPLACE THE BATTERIES INTO THE THERMO-HYGRO SENSOR The outdoor thermo-hygro sensor works with 2 x “AA”, IEC LR6 1.5V batteries. To install and replace the batteries, please follow the steps below: 1. Uninstall the rain cover of the sensor. 2. Remover the battery compartment cover. 3. Insert
Streszczenie treści zawartej na stronie nr. 13
Note: In the event of changing batteries in any of the units, all units need to be reset by following the setting up procedures. This is because a random security code is assigned by the thermo-hygro sensor at start-up and this code must be received and stored by the Weather Center in the first 30 seconds of power being supplied to it. BATTERY CHANGE: It is recommended to replace the batteries in all units every 24 months to ensure optimum accuracy of these units. Please participate
Streszczenie treści zawartej na stronie nr. 14
FUNCTION KEYS: Weather Center: The Weather Center has 5 easy-to-use function keys. HISTORY key Set key MIN/MAX key + key ALARM key SET key • Press to enter manual setting modes: LCD contrast, Manual time setting, 12/24 hour time display, Calendar setting, ºF/ºC temperature unit, Wind speed unit, Rainfall unit, Pressure unit, Relative pressure reference setting, Weather Tendency Sensitivity Value setting, Storm warning sensitivity setting and Storm Alarm On/Off
Streszczenie treści zawartej na stronie nr. 15
+ key • Press to change the calendar display to the preset alarm time, date, weekday + date or seconds in the time display • Press to adjust (increase) the level of different settings • Stop the alarm during the time alarm or weather alarm ringing • Press to confirm to reset the max/min record • To switch on the backlight HISTORY key • Press to display the weather data history records • Stop the alarm during the time alarm or weather alarm ringing • Press to exit manual setting mod
Streszczenie treści zawartej na stronie nr. 16
Note: The LED backlight will be on and last for 15 seconds for every simple key- press. The LED will keep lighting when the key is "pressed and held". LCD SCREEN The LCD screen is split into 5 sections displaying the following information: 1. Time and date 2. Wind data 3. Outdoor temperature and humidity, 4. Air pressure and Rainfall data 5. Air pressure history and Weather forecast. 15
Streszczenie treści zawartej na stronie nr. 17
Low battery indicator Time alarm icon Time display Calendar display Buzzer off indicator Wind direction display and wind speed in Beaufort scale Wind speed Hi/ Lo alarm icon Wind Chill in °F or °C Wind speed in mph, km/h or m/s Outdoor relative Outdoor temperature in °F or ºC humidity in % Outdoor temp. Outdoor Humidity alarm icon alarm icon Relative air pressure display in inHg or hPa Total rainfall in inch or mm Weather tendency
Streszczenie treści zawartej na stronie nr. 18
MANUAL SETTING: The following manual settings can be changed once the SET key is pressed: • LCD contrast setting • Manual time setting • 12/24 hour time display • Calendar setting • °F/ °C temperature unit setting • Wind speed unit • Rainfall unit setting • Air pressure unit setting • Relative pressure reference value setting • Weather Tendency Sensitivity value • Storm warning threshold value • Alarm On/ Off setting LCD CONTRAST SETTING Digit flashing The LCD contr
Streszczenie treści zawartej na stronie nr. 19
MANUAL TIME SETTING: You then may manually set the time of the clock by following the steps below: Minutes flashing Hour flashing 1. The hour digit will start flashing. 2. Use the + or MIN/MAX key to set the hour. 3. Press the SET key to switch to the minutes. The minute digit will start flashing. 4. Use the + or MIN/MAX key to set the minute. 5. Confirm the time with the SET key and enter the 12/24 HOUR TIME DISPLAY SETTING. 12/24 HOUR TIME DISPLAY SETTING: Digit
Streszczenie treści zawartej na stronie nr. 20
2. Confirm with the SET key and enter the CALENDAR SETTING. CALENDAR SETTING: "Date. Month." (for 24h time display) "Month. Date." (for 12h time display) Year The date default of the Weather Center is 1. 1. of year 2005. The date can be set manually by proceeding as follows. 1. The year digit starts flashing. 2. Use the + or MIN/MAX key to set the year. The range runs from "00" (2000) to "99" (2099). 3. Press the SET key to confirm the year and enter the month settin