Streszczenie treści zawartej na stronie nr. 1
Installation Instructions / Warranty
Raindance Allrounder
28110XX1
Wall Outlet Adapter with Hose
Connection
28108XX1
Streszczenie treści zawartej na stronie nr. 2
Raindance Allrounder 28110XX1 Technical Data Max. flow rate of showerhead 2.5 gpm Determining the mounting height (X) The Allrounder should be mounted according to the preferences of the users. It should be conve- nient for all adult users. 2
Streszczenie treści zawartej na stronie nr. 3
Install the Allrounder with the Optional Wall Outlet Adapter with Hose Connection 28108XX1 If you are not using the 28108XX1 wall outlet adapter, go to page 9. Roughing in Install a properly anchored 1/2" NPT drop-eared ell, at least 2" behind the surface of the finished wall. Install a test nipple in the ell. When the finished wall is complete, mark the test nipple at the wall surface. Remove the test nipple. Measure the test nipple to the mark. Subtract /8" from this measurement. This
Streszczenie treści zawartej na stronie nr. 4
Installation Wrap both ends of the brass nipple with Teflon tape. Screw it into the mounting piece. Screw the test nipple / mounting piece assembly into the drop-eared ell. Tighten with a 12 mm Allen wrench (not included). Do not overtighten, or damage will result. Seal the wall around the mounting piece with water- proof sealant. Position the mounting plate over the mounting piece. Use a grease pencil or similar tool to mark the position of the screw holes.
Streszczenie treści zawartej na stronie nr. 5
Drill the holes with a 6 mm bit. Use extreme caution - do not drill into the water line. Install the anchors. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Install the mounting plate, using the screws and offset bushings provided. Remove the long bottom mounting screw on the All- rounder. Replace with the shorter screw included with the adapter. 5
Streszczenie treści zawartej na stronie nr. 6
Attach the Allrounder to the mounting plate. Tighten the set screw. Install the handshower Place a black rubber washer in one end of the hose. Screw this end to the wall outlet adapter. Place the screen washer in the other end of the hose. Screw this end to the handshower. Slide the handshower into the handshower holder. Guide the hose over the hose hook. 6
Streszczenie treści zawartej na stronie nr. 7
Replacement Parts 28108001 1 check valve 90000 2 screw 9598000 Check Valve Maintenance: Backflow preven- 1 tion is provided by a check valve, which is integral to the wall outlet adapter. The check valve should be 2 removed and cleaned yearly.
Streszczenie treści zawartej na stronie nr. 8
Corner Mount Kit 28105XX0 Note: The corner mount kit is not for use with the 28108XX1 wall outlet adapter. Position the corner mount against the wall at the desired location. Mark the positions of the screw holes. Put the mount aside. Drill the holes using a 6 mm bit. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Install the corner mount with the screws and offset bushings. Install the Allrounder (see page 10). T
Streszczenie treści zawartej na stronie nr. 9
Install the 28110XX1 Allrounder Do not drill through the mounting plate. Place the mounting plate against the wall at the de- sired location. Mark the locations of the screw holes. Put the mounting plate away in a safe location. Drill the holes, using a 6 mm bit. 9
Streszczenie treści zawartej na stronie nr. 10
Install the anchors. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Secure the mounting plate to the wall with the screws and the offset bushings. The set screw should be on top. Place the Allrounder over the mounting bracket (1). Tighten the set screw (2). Install the handshower: Place a black rubber washer in one end of the hose. Connect this end of the hose to the wall outlet (not included). Place the scree
Streszczenie treści zawartej na stronie nr. 11
Slide the handshower into the holder, until the holder grips it firmly. Guide the hose over the hose hook. Using the Allrounder To adjust the handshower height: Pull or push the Allrounder to the desired position. Turn the knob to the front to make the Allrounder easier to move. Turn the knob to the rear to make it harder to move. 11
Streszczenie treści zawartej na stronie nr. 12
Raindance E 150 Air 3-Jet Handshower 28518XX1 Change the spray modes Rain AIR Push the function lever until it is next to the name of the desired function. The Raindance has spray modes. Balance AIR function lever Whirl AIR Limescale Removal The spray channels on the Raindance are protected by the Rubit!™ self-cleaning system. If scale deposits are noticed, turn the water on lightly and rub across the channels with a sponge or fingers Remove scale deposits on the spray face by usin
Streszczenie treści zawartej na stronie nr. 13
Replacement parts 28110XX1 1 2 1 handshower 28518XX1 2 Techniflex hose 2826XX mounting plate 9609XX0 corner mount kit 28105000 (optional - not for use with wall outlet adapter) XX = color 00 = chrome 82 = brushed nickel 1
Streszczenie treści zawartej na stronie nr. 14
Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets, kitchen faucets, and showers consist of very different materials to comply with the needs of the market with regard to design and functionality. To avoid damage and returns, it is necessary to consider certain criteria when cleaning. Cleaning Materials for Faucets and Showers Acids are a necessary ingredient of cleaning materials for removing lime, however please pay attention to the following points when cleaning faucet
Streszczenie treści zawartej na stronie nr. 15
the product for use primarily for any other purpose, including, without limitation, a commercial purpose, this warranty extends only (i) for 1 year, with respect to Hansgrohe and Commercial products, and (ii) for 5 years, with respect to AXOR products. THIS WARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT PAY FOR: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper i
Streszczenie treści zawartej na stronie nr. 16
Hansgrohe, Inc. • 190 Bluegrass Lakes Parkway • Alpharetta, GA 000 Tel. 0-60-9880 • Fax 0-60-988 www.hansgrohe-usa.com US - Installation Instructions • Part No. 90661501 • Revised 01/2008