Streszczenie treści zawartej na stronie nr. 1
Installation
Instructions
TDB3104
®
Terreon 54" Semi-Circular Deep
Bowl Washfountain with
TDB3104 with Push Button Air Valve
Air Metering Valve
WF3204
®
Terreon Extra Height 54" Semi-
Circular Classic Washfountain
with 9" Deep Bowl and
Air Metering Valve
TDB3104 Juvenile Height with
Table of Contents
Push Button Air Valve
Pre-Installation Information . . . . . . . . . . . . . . . . . 2
Model TDB3104 Washfountain Dimensions . . . . 3
Model WF3204 Washfountain Dimensions . . . . . .4
Washfountain
Streszczenie treści zawartej na stronie nr. 2
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Pre-Installation Information IMPORTANT: Read this entire installation manual to ensure proper installation. IMPORTANT: Flush all the water supply lines before making connections. IMPORTANT: Main water supply to the unit should be ON at all times. IMPORTANT: This installation manual and parts list should be filed by the owner’s maintenance department. Cylindrical air valve The air valve pu
Streszczenie treści zawartej na stronie nr. 3
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Semi-Circular Washfountain Dimensions Model TDB3104 32-1/4" 54" Semi-circular - side view (819) Optional equipment may not comply with all ADA 5-1/4" (133) dimensional guidelines ADJUST TO TOWEL DISPENSER MOUNTING HOLES 6" (152) 64" (1626) WITH SOAP 22-3/4" 55-1/2" (1410) WITHOUT SOAP (577) 55-3/4" (1416) 47-1/4" (1200) 40" 43-3/4" (1111) (1016) 34" (864) 27" (686) 23-1/2" (597) Figure
Streszczenie treści zawartej na stronie nr. 4
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Semi-Circular Washfountain Dimensions (juvenile height) 32-1/4" (819) Model TDB3104 54" Semi-circular - side view 5-1/4" (133) Optional equipment may not comply with all ADA dimensional guidelines ADJUST TO TOWEL DISPENSER MOUNTING HOLES 6" (152) *59-1/2" (1511) WITH SOAP *51" (1295) WITHOUT SOAP 22-3/4" (577) *51-1/4" (1301) *42-5/8" (1084) *39-1/8" (994) *34" (864) *30" (762) Figure 1
Streszczenie treści zawartej na stronie nr. 5
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Semi-Circular Washfountain Dimensions 32-1/4" Model WF3204 (819) 54" Semi-circular - side view 22-3/4" (577) Model WF3204 is not ADA compliant 5-1/4" (133) ADJUST TO TOWEL DISPENSER MOUNTING HOLES 6" (152) 64" (1626) WITH SOAP 55-1/2" (1410) WITHOUT SOAP 55-3/4" (1416) 47-1/4" (1200) 41" 43-3/4" (1041) (1111) 34" (864) 23-1/2" (597) Figure 1d 15" (381 Bradley Corporation • 215-1470 Rev.
Streszczenie treści zawartej na stronie nr. 6
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Rough-In Specifications Type A Drain - Supplies from below or through wall - Vent from below or through wall off-drain (mm) NOTE: Supply lines for one to two washfountains should be 1”; for three washfountains, 1-1/4”. For more than three washfountains, pipe sizes should be increased proportionately. Figure 2a Type B Drain - Supplies from above - Vent through ceiling off trap inside pede
Streszczenie treści zawartej na stronie nr. 7
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Rough-In Specifications continued . . . Type H Drain - Supplies from below or through wall - Vented through ceiling off trap inside pedestal (mm) NOTE: Supply lines for one to two washfountains should be 1”; for three washfountains, 1-1/4”. For more than three washfountains, pipe sizes should be increased Figure 2c proportionately. Type O Drain - Supplies from above - Vented from belo
Streszczenie treści zawartej na stronie nr. 8
Centerline of Washfountain Centerline of Washfountain Centerline of Washfountain Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Installation Instructions Step 1: Installing the drain 1. Rough in supply and drain piping as required for your installation (see pages 6-7 for rough-ins of the optional installations). 2. Assemble the drain to the dimension shown in Figure 3 for the bowl you are installing. NOTE: All piping shown in d
Streszczenie treści zawartej na stronie nr. 9
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Installation Instructions continued . . . Step 2: Bowl/pedestal mounting and assembly 1. Position pedestal at desired location and mark the position of the (2) pedestal wall mounting locations and (2) pedestal floor mounting locations (see Figure 5b). TAS Option: Place TAS spacer on floor over the mounting holes. Place pedestal on top of the spacer. 2. Secure pedestal to wall and floor w
Streszczenie treści zawartej na stronie nr. 10
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Installation Instructions continued . . . Step 3: Installing drain spud in bowl NOTE: Seal between drain spud and drain hole with plumber’s putty (supplied by installer). 1. Loosely attach the drain spud to the bowl with the locknut and washer as shown in Figure 6. B Trap Option: Attach B Trap to drain spud. Tie Pipe Option: Attach Tie Pipe Bracket to drain spud. 2. Tighten the spud and
Streszczenie treści zawartej na stronie nr. 11
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Installation Instructions continued . . . Step 4a: Air Metering Valve assembly for A drain and O drain units without Tie Pipe option 1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 7). 2. Place sprayhead with 1/2" tubing onto support tube. Run the tubing down through the support tube and connect to valve tube connector. Make sure the spray holes po
Streszczenie treści zawartej na stronie nr. 12
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Installation Instructions continued . . . 4. Place the actuator module assembly on top of sprayhead. Rotate until actuator module locks in with tie bar. Drop two 1/8" diameter tubes down to valve assembly and connect to the air valve. NOTE: Skip to number 5 for units without soap. • For units with soap option, install the spacer, soap dispenser and cover using the third tie rod (8-5/8" l
Streszczenie treści zawartej na stronie nr. 13
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Installation Instructions continued . . . Step 4b: Air Metering Valve assembly for B and H units and units with Tie Pipe option 1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 9). 2. Place sprayhead with 1/2" tubing onto support tube. Run the tubing down through support tube. 3. Insert the 1-1/2" vent pipe (supplied by installer) down through the s
Streszczenie treści zawartej na stronie nr. 14
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Installation Instructions continued . . . 4. Place the actuator module assembly on top of the sprayhead. Drop 1/8" diameter tube down to the valve assembly and connect to the air valve. Make sure the spray holes point away from the wall. NOTE: Skip to number 5 for units without soap. • For units with soap option, slide the spacer and soap dispenser over the 1-1/2" pipe. 5. Position the up
Streszczenie treści zawartej na stronie nr. 15
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Installation Instructions continued . . . VALVE ASSEMBLY S45-2246 3/8" TUBE TO SPRAYHEAD THERMOSTATIC MIXING VALVE ASSEMBLY VOLUME CONTROL VALVE FLEXIBLE HOSE 1/8" TUBING TO ACTUATOR CHECK STOP AIR VALVE ASSEMBLY CHECK STOP AIR VALVE TIMER (DO NOT APPLY PIPE SEALANT Figure 11a TO COMPRESSION FITTINGS) Bradley Corporation • 215-1470 Rev. H; EN 06-915 2/8/07 15
Streszczenie treści zawartej na stronie nr. 16
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Installation Instructions continued . . . Step 5: Valve and Tubing Connections NOTE: Flush supply lines before making connections. 1. Attach hot and cold flexible supply lines to mixing valve assembly, two places (see Figure 11a and Figure 11b). 2. Hang valve assembly on pedestal valve bracket. 3. Use wire tie to secure valving to valve bracket. VALVE AND TUBING CONNECTIONS - AIR METERI
Streszczenie treści zawartej na stronie nr. 17
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Installation Instructions continued . . . NOTE: Flush supply lines before making connections. 4. Follow the procedures below and refer to Figure 12 when installing tubing to ensure that you achieve a leakproof seal. Install 3/8" supply tubing in the sprayhead using the male tube con- nector. • Using a sharp razor, cut tubing squarely and remove any burrs. DO NOT pinch or crush end of t
Streszczenie treści zawartej na stronie nr. 18
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Installation Instructions continued . . . NOTE: The Vernatherm TMA valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110°F (43°C) may cause scalding. 5. Check the temperature when approximately 1.0 GPM water flow is reached and adjust if neces- sary (the range of the
Streszczenie treści zawartej na stronie nr. 19
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve Installation Instructions TDB3104, WF3204 Cleaning/Maintenance Instructions for Terreon® ® Material Description: Terreon is a NAHB Certified densified solid surface material composed of polyester resin and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Routine Cleaning: Clean daily or as often as conditions require using a standard commer
Streszczenie treści zawartej na stronie nr. 20
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve TDB3104, WF3204 Installation Instructions Cleaning and Maintenance Instructions for Stainless Steel Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particularly under corrosive conditions, is essential. Always start with the simplest solution and work your way toward the more complicated. Routine cleaning: Daily or as often as needed use a solution of warm water